Energy Saving Analysis and Simulation for Home Electricity
This paper presents the energy saving method by applying the voltage control technique on a single-phase AC source to a thyristor rectifier and an IGBT inverter with LC filter. Based on the LC filter parameter, the values of the gain for the controller are obtainable. The proposed controller structu...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Scientific Research Publishing
2020
|
Subjects: | |
Online Access: | https://eprints.ums.edu.my/id/eprint/26426/1/Energy%20Saving%20Analysis%20and%20Simulation%20for%20Home%20Electricity.pdf https://eprints.ums.edu.my/id/eprint/26426/2/Energy%20Saving%20Analysis%20and%20Simulation%20for%20Home%20Electricity1.pdf https://eprints.ums.edu.my/id/eprint/26426/ https://doi.org/10.4236/jpee.2020.89004 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ums.eprints.26426 |
---|---|
record_format |
eprints |
spelling |
my.ums.eprints.264262021-01-06T13:37:20Z https://eprints.ums.edu.my/id/eprint/26426/ Energy Saving Analysis and Simulation for Home Electricity Nader Nassif Barsoum Farah Talib TA Engineering (General). Civil engineering (General) This paper presents the energy saving method by applying the voltage control technique on a single-phase AC source to a thyristor rectifier and an IGBT inverter with LC filter. Based on the LC filter parameter, the values of the gain for the controller are obtainable. The proposed controller structure consists of two loops arranged in a cascaded model. The output of the first loop is the capacitor current. This current is added to the load current in order to obtain the current reference. This reference current value will be compared with the inverter current which produces the error signal to be fed into the second loop in the cascade system. The output of the second loop is the inverter voltage. This voltage is added to the load voltage to produce the voltage reference. This reference is fed to the pulse width modulation generator via the controller and compared with the triangular wave. This energy-saving circuit is designed in blocks using MATLAB Simulink. Scientific Research Publishing 2020 Article PeerReviewed text en https://eprints.ums.edu.my/id/eprint/26426/1/Energy%20Saving%20Analysis%20and%20Simulation%20for%20Home%20Electricity.pdf text en https://eprints.ums.edu.my/id/eprint/26426/2/Energy%20Saving%20Analysis%20and%20Simulation%20for%20Home%20Electricity1.pdf Nader Nassif Barsoum and Farah Talib (2020) Energy Saving Analysis and Simulation for Home Electricity. Journal of Power and Energy Engineering, 8. pp. 35-50. ISSN 2327-5901 https://doi.org/10.4236/jpee.2020.89004 |
institution |
Universiti Malaysia Sabah |
building |
UMS Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Sabah |
content_source |
UMS Institutional Repository |
url_provider |
http://eprints.ums.edu.my/ |
language |
English English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Nader Nassif Barsoum Farah Talib Energy Saving Analysis and Simulation for Home Electricity |
description |
This paper presents the energy saving method by applying the voltage control technique on a single-phase AC source to a thyristor rectifier and an IGBT inverter with LC filter. Based on the LC filter parameter, the values of the gain for the controller are obtainable. The proposed controller structure consists of two loops arranged in a cascaded model. The output of the first loop is the capacitor current. This current is added to the load current in order to obtain the current reference. This reference current value will be compared with the inverter current which produces the error signal to be fed into the second loop in the cascade system. The output of the second loop is the inverter voltage. This voltage is added to the load voltage to produce the voltage reference. This reference is fed to the pulse width modulation generator via the controller and compared with the triangular wave. This energy-saving circuit is designed in blocks using MATLAB Simulink. |
format |
Article |
author |
Nader Nassif Barsoum Farah Talib |
author_facet |
Nader Nassif Barsoum Farah Talib |
author_sort |
Nader Nassif Barsoum |
title |
Energy Saving Analysis and Simulation for Home Electricity |
title_short |
Energy Saving Analysis and Simulation for Home Electricity |
title_full |
Energy Saving Analysis and Simulation for Home Electricity |
title_fullStr |
Energy Saving Analysis and Simulation for Home Electricity |
title_full_unstemmed |
Energy Saving Analysis and Simulation for Home Electricity |
title_sort |
energy saving analysis and simulation for home electricity |
publisher |
Scientific Research Publishing |
publishDate |
2020 |
url |
https://eprints.ums.edu.my/id/eprint/26426/1/Energy%20Saving%20Analysis%20and%20Simulation%20for%20Home%20Electricity.pdf https://eprints.ums.edu.my/id/eprint/26426/2/Energy%20Saving%20Analysis%20and%20Simulation%20for%20Home%20Electricity1.pdf https://eprints.ums.edu.my/id/eprint/26426/ https://doi.org/10.4236/jpee.2020.89004 |
_version_ |
1760230497493975040 |
score |