Fixed bed adsorption for wastewater treatment

This study is about the comparison of flow arrangement in fixed bed adsorption for wastewater treatment and also to study the equilibrium adsorption in batch mode,to study the column adsorption for dye removal,and to study the effect of flow pattern,flow rate and initial dye concentration.The adsorp...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Mutammimul Ula, W. Abd. Latif
Format: Undergraduates Project Papers
Language:English
Published: 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/4367/1/CD6435_WAN_MUHAMMAD_MUTAMIMUL.pdf
http://umpir.ump.edu.my/id/eprint/4367/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.4367
record_format eprints
spelling my.ump.umpir.43672021-07-16T04:18:55Z http://umpir.ump.edu.my/id/eprint/4367/ Fixed bed adsorption for wastewater treatment Muhammad Mutammimul Ula, W. Abd. Latif TP Chemical technology This study is about the comparison of flow arrangement in fixed bed adsorption for wastewater treatment and also to study the equilibrium adsorption in batch mode,to study the column adsorption for dye removal,and to study the effect of flow pattern,flow rate and initial dye concentration.The adsorption of methylene blue from wastewater onto granular activated carbon (GAC) in fixed bed was investigated and breakthrough data of the dyes was determined.This research is run in small scale column at constant temperature and pH value.The equilibrium study was done on batch mode and the data fitted with Langmuir model so that the design parameter will be evaluated.The column mode was studied by considering varies parameter to find suitable flow pattern (up-flow and down-flow) and optimum flow condition.Both the flows will be subject to static mode adsorption studies.The effects of bed height,initial concentration and flow rate on breakthrough curve were investigated.It is found that breakthrough time and adsorption capacity increases by increasing flow rate, increasing initial concentration and decreasing bed height. The results show that the up-flow arrangement is better performance than the down-flow arrangement.This is due to the higher of the breakthrough time and the equilibrium capacity for up-flow column in all experimental conditions. 2012-01 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/4367/1/CD6435_WAN_MUHAMMAD_MUTAMIMUL.pdf Muhammad Mutammimul Ula, W. Abd. Latif (2012) Fixed bed adsorption for wastewater treatment. Faculty of Chemical & Natural Resource Engineering, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Muhammad Mutammimul Ula, W. Abd. Latif
Fixed bed adsorption for wastewater treatment
description This study is about the comparison of flow arrangement in fixed bed adsorption for wastewater treatment and also to study the equilibrium adsorption in batch mode,to study the column adsorption for dye removal,and to study the effect of flow pattern,flow rate and initial dye concentration.The adsorption of methylene blue from wastewater onto granular activated carbon (GAC) in fixed bed was investigated and breakthrough data of the dyes was determined.This research is run in small scale column at constant temperature and pH value.The equilibrium study was done on batch mode and the data fitted with Langmuir model so that the design parameter will be evaluated.The column mode was studied by considering varies parameter to find suitable flow pattern (up-flow and down-flow) and optimum flow condition.Both the flows will be subject to static mode adsorption studies.The effects of bed height,initial concentration and flow rate on breakthrough curve were investigated.It is found that breakthrough time and adsorption capacity increases by increasing flow rate, increasing initial concentration and decreasing bed height. The results show that the up-flow arrangement is better performance than the down-flow arrangement.This is due to the higher of the breakthrough time and the equilibrium capacity for up-flow column in all experimental conditions.
format Undergraduates Project Papers
author Muhammad Mutammimul Ula, W. Abd. Latif
author_facet Muhammad Mutammimul Ula, W. Abd. Latif
author_sort Muhammad Mutammimul Ula, W. Abd. Latif
title Fixed bed adsorption for wastewater treatment
title_short Fixed bed adsorption for wastewater treatment
title_full Fixed bed adsorption for wastewater treatment
title_fullStr Fixed bed adsorption for wastewater treatment
title_full_unstemmed Fixed bed adsorption for wastewater treatment
title_sort fixed bed adsorption for wastewater treatment
publishDate 2012
url http://umpir.ump.edu.my/id/eprint/4367/1/CD6435_WAN_MUHAMMAD_MUTAMIMUL.pdf
http://umpir.ump.edu.my/id/eprint/4367/
_version_ 1706957153371160576
score 13.211869