Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project
In order to explore the recommended roughness value and application prospect of SCL impermeable film and SK spray polyurea in reducing roughness and increasing flow in water conservancy projects, the prototype observation test is carried out in the typical aqueduct of the pumping irrigation area in...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier Ltd
2022
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/42736/1/Application%20and%20effect%20of%20SCL%20film%20and%20SK%20polyurea.pdf http://umpir.ump.edu.my/id/eprint/42736/2/Application%20and%20effect%20of%20SCL%20film%20and%20SK%20polyurea%20in%20aqueduct%20roughness%20reduction%20transformation%20project_ABS.pdf http://umpir.ump.edu.my/id/eprint/42736/ https://doi.org/10.1016/j.pce.2022.103231 https://doi.org/10.1016/j.pce.2022.103231 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.42736 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.427362025-01-07T03:58:56Z http://umpir.ump.edu.my/id/eprint/42736/ Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project Li, Chaochao Li, Mingyang Xu, Haoli Gu, Jingchao Lim, Kar Sing T Technology (General) TA Engineering (General). Civil engineering (General) In order to explore the recommended roughness value and application prospect of SCL impermeable film and SK spray polyurea in reducing roughness and increasing flow in water conservancy projects, the prototype observation test is carried out in the typical aqueduct of the pumping irrigation area in Ningxia, and one-dimensional constant flow model based on HEC-RAS is built. The roughness value before and after the engineering transformation of the aqueduct is compared to test the effect of different roughness reducing materials. The results show that:the roughness value of the original concrete aqueduct is about 0.0131, the roughness value of SCL is 0.0115, and the roughness value of SK is 0.0098. The effective reduction of roughness of SCL impermeable film is 12.21%, However, the SK spray polyurea effectively reduced the roughness rate of 25.19%. The effective flow increase of SCL impermeable film is 13.91%, while the effective flow increase of SK scrap polyurea is 33.67%. According to the effect of roughness reducing, flow increasing, and construction technology of the tow different materials, SK spray polyurea will be more suitable for application of water supply and distribution channel renovation project with less cost, easier construction, and more effective. Elsevier Ltd 2022-12 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/42736/1/Application%20and%20effect%20of%20SCL%20film%20and%20SK%20polyurea.pdf pdf en http://umpir.ump.edu.my/id/eprint/42736/2/Application%20and%20effect%20of%20SCL%20film%20and%20SK%20polyurea%20in%20aqueduct%20roughness%20reduction%20transformation%20project_ABS.pdf Li, Chaochao and Li, Mingyang and Xu, Haoli and Gu, Jingchao and Lim, Kar Sing (2022) Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project. Physics and Chemistry of the Earth, 128 (103231). pp. 1-9. ISSN 1474-7065. (Published) https://doi.org/10.1016/j.pce.2022.103231 https://doi.org/10.1016/j.pce.2022.103231 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
T Technology (General) TA Engineering (General). Civil engineering (General) |
spellingShingle |
T Technology (General) TA Engineering (General). Civil engineering (General) Li, Chaochao Li, Mingyang Xu, Haoli Gu, Jingchao Lim, Kar Sing Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project |
description |
In order to explore the recommended roughness value and application prospect of SCL impermeable film and SK spray polyurea in reducing roughness and increasing flow in water conservancy projects, the prototype observation test is carried out in the typical aqueduct of the pumping irrigation area in Ningxia, and one-dimensional constant flow model based on HEC-RAS is built. The roughness value before and after the engineering transformation of the aqueduct is compared to test the effect of different roughness reducing materials. The results show that:the roughness value of the original concrete aqueduct is about 0.0131, the roughness value of SCL is 0.0115, and the roughness value of SK is 0.0098. The effective reduction of roughness of SCL impermeable film is 12.21%, However, the SK spray polyurea effectively reduced the roughness rate of 25.19%. The effective flow increase of SCL impermeable film is 13.91%, while the effective flow increase of SK scrap polyurea is 33.67%. According to the effect of roughness reducing, flow increasing, and construction technology of the tow different materials, SK spray polyurea will be more suitable for application of water supply and distribution channel renovation project with less cost, easier construction, and more effective. |
format |
Article |
author |
Li, Chaochao Li, Mingyang Xu, Haoli Gu, Jingchao Lim, Kar Sing |
author_facet |
Li, Chaochao Li, Mingyang Xu, Haoli Gu, Jingchao Lim, Kar Sing |
author_sort |
Li, Chaochao |
title |
Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project |
title_short |
Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project |
title_full |
Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project |
title_fullStr |
Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project |
title_full_unstemmed |
Application and effect of SCL film and SK polyurea in aqueduct roughness reduction transformation project |
title_sort |
application and effect of scl film and sk polyurea in aqueduct roughness reduction transformation project |
publisher |
Elsevier Ltd |
publishDate |
2022 |
url |
http://umpir.ump.edu.my/id/eprint/42736/1/Application%20and%20effect%20of%20SCL%20film%20and%20SK%20polyurea.pdf http://umpir.ump.edu.my/id/eprint/42736/2/Application%20and%20effect%20of%20SCL%20film%20and%20SK%20polyurea%20in%20aqueduct%20roughness%20reduction%20transformation%20project_ABS.pdf http://umpir.ump.edu.my/id/eprint/42736/ https://doi.org/10.1016/j.pce.2022.103231 https://doi.org/10.1016/j.pce.2022.103231 |
_version_ |
1822924881031856128 |
score |
13.232389 |