P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis

Haptic sensation research based on the event's related potential (ERP) has been carried out extensively in order to help amputees to be able feel and control their prosthetic hand. Clinically, somatosensory evoked potential is suggested in the pain-related evoked potential and able to control a...

Full description

Saved in:
Bibliographic Details
Main Authors: Nur Amalina, Has, Mohd Najeb, Jamaludin, Sujana, Mohd Rejab, Zulkifli, Ahmad@Manap, Nurul Farha, Zainuddin, Abdul Haris, Abdul Salam, Ai Reen, Chu, Muhammad Amir, As'ari
Format: Conference or Workshop Item
Language:English
English
Published: Institute of Electrical and Electronics Engineers Inc. 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/42414/1/P300%20somatosensory%20validation%20of%20vibrotactile%20haptic.pdf
http://umpir.ump.edu.my/id/eprint/42414/2/P300%20somatosensory%20validation%20of%20vibrotactile%20haptic%20feedback%20for%20upper%20limb%20prosthesis_ABS.pdf
http://umpir.ump.edu.my/id/eprint/42414/
https://doi.org/10.1109/NBEC53282.2021.9618709
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.42414
record_format eprints
spelling my.ump.umpir.424142024-10-30T04:42:05Z http://umpir.ump.edu.my/id/eprint/42414/ P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis Nur Amalina, Has Mohd Najeb, Jamaludin Sujana, Mohd Rejab Zulkifli, Ahmad@Manap Nurul Farha, Zainuddin Abdul Haris, Abdul Salam Ai Reen, Chu Muhammad Amir, As'ari T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics Haptic sensation research based on the event's related potential (ERP) has been carried out extensively in order to help amputees to be able feel and control their prosthetic hand. Clinically, somatosensory evoked potential is suggested in the pain-related evoked potential and able to control a computer using a brain to computer interface system called BCI. Somatosensory response can be evoked by tactile vibrators whether it is directly and indirect contact with skin. Somatosensory evoked potential has been reported to have lower signal to noise ratio compared to the common visual evoked potential. P300 based on somatosensory evoked potential were discovered as a benchmark that a person will generate P300 whenever decision making as simple as lift their finger take place. The aim of this paper is to identify the best location of the upper limb for tactile haptic placement and investigating whether the vibration motor haptic tactile setup reflect on the P300 somatosensory response from encephalography recordings. Results show that most of the subjects correctly guesses during upper arm position of haptic tactile feedback than the lower arm position. The vibration motor haptic tactile feedback setup was validated via experiment with mental task in order to elicit P300 somatosensory event related potential (ERP). Institute of Electrical and Electronics Engineers Inc. 2021 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/42414/1/P300%20somatosensory%20validation%20of%20vibrotactile%20haptic.pdf pdf en http://umpir.ump.edu.my/id/eprint/42414/2/P300%20somatosensory%20validation%20of%20vibrotactile%20haptic%20feedback%20for%20upper%20limb%20prosthesis_ABS.pdf Nur Amalina, Has and Mohd Najeb, Jamaludin and Sujana, Mohd Rejab and Zulkifli, Ahmad@Manap and Nurul Farha, Zainuddin and Abdul Haris, Abdul Salam and Ai Reen, Chu and Muhammad Amir, As'ari (2021) P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis. In: 1st National Biomedical Engineering Conference, NBEC 2021. 1st National Biomedical Engineering Conference, NBEC 2021 , 9 - 10 November 2021 , Virtual, Online. pp. 19-24.. ISBN 978-166543607-6 (Published) https://doi.org/10.1109/NBEC53282.2021.9618709
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
TL Motor vehicles. Aeronautics. Astronautics
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
TL Motor vehicles. Aeronautics. Astronautics
Nur Amalina, Has
Mohd Najeb, Jamaludin
Sujana, Mohd Rejab
Zulkifli, Ahmad@Manap
Nurul Farha, Zainuddin
Abdul Haris, Abdul Salam
Ai Reen, Chu
Muhammad Amir, As'ari
P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis
description Haptic sensation research based on the event's related potential (ERP) has been carried out extensively in order to help amputees to be able feel and control their prosthetic hand. Clinically, somatosensory evoked potential is suggested in the pain-related evoked potential and able to control a computer using a brain to computer interface system called BCI. Somatosensory response can be evoked by tactile vibrators whether it is directly and indirect contact with skin. Somatosensory evoked potential has been reported to have lower signal to noise ratio compared to the common visual evoked potential. P300 based on somatosensory evoked potential were discovered as a benchmark that a person will generate P300 whenever decision making as simple as lift their finger take place. The aim of this paper is to identify the best location of the upper limb for tactile haptic placement and investigating whether the vibration motor haptic tactile setup reflect on the P300 somatosensory response from encephalography recordings. Results show that most of the subjects correctly guesses during upper arm position of haptic tactile feedback than the lower arm position. The vibration motor haptic tactile feedback setup was validated via experiment with mental task in order to elicit P300 somatosensory event related potential (ERP).
format Conference or Workshop Item
author Nur Amalina, Has
Mohd Najeb, Jamaludin
Sujana, Mohd Rejab
Zulkifli, Ahmad@Manap
Nurul Farha, Zainuddin
Abdul Haris, Abdul Salam
Ai Reen, Chu
Muhammad Amir, As'ari
author_facet Nur Amalina, Has
Mohd Najeb, Jamaludin
Sujana, Mohd Rejab
Zulkifli, Ahmad@Manap
Nurul Farha, Zainuddin
Abdul Haris, Abdul Salam
Ai Reen, Chu
Muhammad Amir, As'ari
author_sort Nur Amalina, Has
title P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis
title_short P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis
title_full P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis
title_fullStr P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis
title_full_unstemmed P300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis
title_sort p300 somatosensory validation of vibrotactile haptic feedback for upper limb prosthesis
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/42414/1/P300%20somatosensory%20validation%20of%20vibrotactile%20haptic.pdf
http://umpir.ump.edu.my/id/eprint/42414/2/P300%20somatosensory%20validation%20of%20vibrotactile%20haptic%20feedback%20for%20upper%20limb%20prosthesis_ABS.pdf
http://umpir.ump.edu.my/id/eprint/42414/
https://doi.org/10.1109/NBEC53282.2021.9618709
_version_ 1822924729791545344
score 13.235308