Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
Thermal management is a crucial parameter in lithium-ion batteries to maintain the temperature of the batteries within safer working limits. If the optimum working temperature is not maintained, it triggers thermal runaway conditions and causes them to propagate heat from one cell to another within...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Elsevier Ltd
2024
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/41390/1/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material.pdf http://umpir.ump.edu.my/id/eprint/41390/2/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material%20to%20delay%20the%20occurrence%20of%20thermal%20runaway%20event_ABS.pdf http://umpir.ump.edu.my/id/eprint/41390/ https://doi.org/10.1016/j.icheatmasstransfer.2024.107527 https://doi.org/10.1016/j.icheatmasstransfer.2024.107527 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.41390 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.413902024-07-01T01:24:52Z http://umpir.ump.edu.my/id/eprint/41390/ Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event Talele, Virendra Moralı, Uğur Najafi Khaboshan, Hasan Patil, Mahesh Suresh Panchal, Satyam Fraser, Roydon Andrew Fowler, Michael W. T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics Thermal management is a crucial parameter in lithium-ion batteries to maintain the temperature of the batteries within safer working limits. If the optimum working temperature is not maintained, it triggers thermal runaway conditions and causes them to propagate heat from one cell to another within pack level configurations. In battery thermal packaging, several government norms such as GB 38031/32 has suggested that for optimum thermal packaging, there should be a significant delay in the thermal runaway trigger point which can prevent a vehicle from going into catastrophic failure since the driver gets a preventive alert for the high-rise temperature of a cell at an early stage. Delaying thermal runaway occurrence can be effectively achieved by using an integrated layer of PCM. However, present conventional PCMs have a lower thermal conductivity which poses instability in delaying thermal runaway trigger point. This can be improved by using graphene-enhanced composite phase change material, in which the percentage of added extended graphene (EG) determines the improvement in thermophysical property, concisely thermal conductivity of CPCM. The current study examines thermal runaway in widely used cathode materials, LiNiMnCoO2 (NMC) and LiFePO4 (LFP), within a typical large format prismatic cell profile with a commonly used heater-assisted test. The thermal runaway trigger point is monitored for the cases of cell without CPCM and with CPCM to find potential improvement in the delay point. Thermal runaway modeling and statistical safety regime response show that submerging batteries in a CPCM can delay thermal runaway onset by 20 min. When scaling up to a 7S1P battery module level, it is concluded that the smallest addition of EG in CPCM can delay the thermal runaway trigger point and reduce peak temperatures in the battery module over 66 to 113.2 min, which strategically complies with battery safety norms. Elsevier Ltd 2024-06 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/41390/1/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material.pdf pdf en http://umpir.ump.edu.my/id/eprint/41390/2/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material%20to%20delay%20the%20occurrence%20of%20thermal%20runaway%20event_ABS.pdf Talele, Virendra and Moralı, Uğur and Najafi Khaboshan, Hasan and Patil, Mahesh Suresh and Panchal, Satyam and Fraser, Roydon Andrew and Fowler, Michael W. (2024) Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event. International Communications in Heat and Mass Transfer, 155 (107527). pp. 1-16. ISSN 0735-1933. (Published) https://doi.org/10.1016/j.icheatmasstransfer.2024.107527 https://doi.org/10.1016/j.icheatmasstransfer.2024.107527 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics |
spellingShingle |
T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics Talele, Virendra Moralı, Uğur Najafi Khaboshan, Hasan Patil, Mahesh Suresh Panchal, Satyam Fraser, Roydon Andrew Fowler, Michael W. Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event |
description |
Thermal management is a crucial parameter in lithium-ion batteries to maintain the temperature of the batteries within safer working limits. If the optimum working temperature is not maintained, it triggers thermal runaway conditions and causes them to propagate heat from one cell to another within pack level configurations. In battery thermal packaging, several government norms such as GB 38031/32 has suggested that for optimum thermal packaging, there should be a significant delay in the thermal runaway trigger point which can prevent a vehicle from going into catastrophic failure since the driver gets a preventive alert for the high-rise temperature of a cell at an early stage. Delaying thermal runaway occurrence can be effectively achieved by using an integrated layer of PCM. However, present conventional PCMs have a lower thermal conductivity which poses instability in delaying thermal runaway trigger point. This can be improved by using graphene-enhanced composite phase change material, in which the percentage of added extended graphene (EG) determines the improvement in thermophysical property, concisely thermal conductivity of CPCM. The current study examines thermal runaway in widely used cathode materials, LiNiMnCoO2 (NMC) and LiFePO4 (LFP), within a typical large format prismatic cell profile with a commonly used heater-assisted test. The thermal runaway trigger point is monitored for the cases of cell without CPCM and with CPCM to find potential improvement in the delay point. Thermal runaway modeling and statistical safety regime response show that submerging batteries in a CPCM can delay thermal runaway onset by 20 min. When scaling up to a 7S1P battery module level, it is concluded that the smallest addition of EG in CPCM can delay the thermal runaway trigger point and reduce peak temperatures in the battery module over 66 to 113.2 min, which strategically complies with battery safety norms. |
format |
Article |
author |
Talele, Virendra Moralı, Uğur Najafi Khaboshan, Hasan Patil, Mahesh Suresh Panchal, Satyam Fraser, Roydon Andrew Fowler, Michael W. |
author_facet |
Talele, Virendra Moralı, Uğur Najafi Khaboshan, Hasan Patil, Mahesh Suresh Panchal, Satyam Fraser, Roydon Andrew Fowler, Michael W. |
author_sort |
Talele, Virendra |
title |
Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event |
title_short |
Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event |
title_full |
Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event |
title_fullStr |
Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event |
title_full_unstemmed |
Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event |
title_sort |
improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event |
publisher |
Elsevier Ltd |
publishDate |
2024 |
url |
http://umpir.ump.edu.my/id/eprint/41390/1/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material.pdf http://umpir.ump.edu.my/id/eprint/41390/2/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material%20to%20delay%20the%20occurrence%20of%20thermal%20runaway%20event_ABS.pdf http://umpir.ump.edu.my/id/eprint/41390/ https://doi.org/10.1016/j.icheatmasstransfer.2024.107527 https://doi.org/10.1016/j.icheatmasstransfer.2024.107527 |
_version_ |
1822924429214089216 |
score |
13.235362 |