Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event

Thermal management is a crucial parameter in lithium-ion batteries to maintain the temperature of the batteries within safer working limits. If the optimum working temperature is not maintained, it triggers thermal runaway conditions and causes them to propagate heat from one cell to another within...

Full description

Saved in:
Bibliographic Details
Main Authors: Talele, Virendra, Moralı, Uğur, Najafi Khaboshan, Hasan, Patil, Mahesh Suresh, Panchal, Satyam, Fraser, Roydon Andrew, Fowler, Michael W.
Format: Article
Language:English
English
Published: Elsevier Ltd 2024
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/41390/1/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material.pdf
http://umpir.ump.edu.my/id/eprint/41390/2/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material%20to%20delay%20the%20occurrence%20of%20thermal%20runaway%20event_ABS.pdf
http://umpir.ump.edu.my/id/eprint/41390/
https://doi.org/10.1016/j.icheatmasstransfer.2024.107527
https://doi.org/10.1016/j.icheatmasstransfer.2024.107527
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.41390
record_format eprints
spelling my.ump.umpir.413902024-07-01T01:24:52Z http://umpir.ump.edu.my/id/eprint/41390/ Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event Talele, Virendra Moralı, Uğur Najafi Khaboshan, Hasan Patil, Mahesh Suresh Panchal, Satyam Fraser, Roydon Andrew Fowler, Michael W. T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics Thermal management is a crucial parameter in lithium-ion batteries to maintain the temperature of the batteries within safer working limits. If the optimum working temperature is not maintained, it triggers thermal runaway conditions and causes them to propagate heat from one cell to another within pack level configurations. In battery thermal packaging, several government norms such as GB 38031/32 has suggested that for optimum thermal packaging, there should be a significant delay in the thermal runaway trigger point which can prevent a vehicle from going into catastrophic failure since the driver gets a preventive alert for the high-rise temperature of a cell at an early stage. Delaying thermal runaway occurrence can be effectively achieved by using an integrated layer of PCM. However, present conventional PCMs have a lower thermal conductivity which poses instability in delaying thermal runaway trigger point. This can be improved by using graphene-enhanced composite phase change material, in which the percentage of added extended graphene (EG) determines the improvement in thermophysical property, concisely thermal conductivity of CPCM. The current study examines thermal runaway in widely used cathode materials, LiNiMnCoO2 (NMC) and LiFePO4 (LFP), within a typical large format prismatic cell profile with a commonly used heater-assisted test. The thermal runaway trigger point is monitored for the cases of cell without CPCM and with CPCM to find potential improvement in the delay point. Thermal runaway modeling and statistical safety regime response show that submerging batteries in a CPCM can delay thermal runaway onset by 20 min. When scaling up to a 7S1P battery module level, it is concluded that the smallest addition of EG in CPCM can delay the thermal runaway trigger point and reduce peak temperatures in the battery module over 66 to 113.2 min, which strategically complies with battery safety norms. Elsevier Ltd 2024-06 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/41390/1/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material.pdf pdf en http://umpir.ump.edu.my/id/eprint/41390/2/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material%20to%20delay%20the%20occurrence%20of%20thermal%20runaway%20event_ABS.pdf Talele, Virendra and Moralı, Uğur and Najafi Khaboshan, Hasan and Patil, Mahesh Suresh and Panchal, Satyam and Fraser, Roydon Andrew and Fowler, Michael W. (2024) Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event. International Communications in Heat and Mass Transfer, 155 (107527). pp. 1-16. ISSN 0735-1933. (Published) https://doi.org/10.1016/j.icheatmasstransfer.2024.107527 https://doi.org/10.1016/j.icheatmasstransfer.2024.107527
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
TL Motor vehicles. Aeronautics. Astronautics
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
TL Motor vehicles. Aeronautics. Astronautics
Talele, Virendra
Moralı, Uğur
Najafi Khaboshan, Hasan
Patil, Mahesh Suresh
Panchal, Satyam
Fraser, Roydon Andrew
Fowler, Michael W.
Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
description Thermal management is a crucial parameter in lithium-ion batteries to maintain the temperature of the batteries within safer working limits. If the optimum working temperature is not maintained, it triggers thermal runaway conditions and causes them to propagate heat from one cell to another within pack level configurations. In battery thermal packaging, several government norms such as GB 38031/32 has suggested that for optimum thermal packaging, there should be a significant delay in the thermal runaway trigger point which can prevent a vehicle from going into catastrophic failure since the driver gets a preventive alert for the high-rise temperature of a cell at an early stage. Delaying thermal runaway occurrence can be effectively achieved by using an integrated layer of PCM. However, present conventional PCMs have a lower thermal conductivity which poses instability in delaying thermal runaway trigger point. This can be improved by using graphene-enhanced composite phase change material, in which the percentage of added extended graphene (EG) determines the improvement in thermophysical property, concisely thermal conductivity of CPCM. The current study examines thermal runaway in widely used cathode materials, LiNiMnCoO2 (NMC) and LiFePO4 (LFP), within a typical large format prismatic cell profile with a commonly used heater-assisted test. The thermal runaway trigger point is monitored for the cases of cell without CPCM and with CPCM to find potential improvement in the delay point. Thermal runaway modeling and statistical safety regime response show that submerging batteries in a CPCM can delay thermal runaway onset by 20 min. When scaling up to a 7S1P battery module level, it is concluded that the smallest addition of EG in CPCM can delay the thermal runaway trigger point and reduce peak temperatures in the battery module over 66 to 113.2 min, which strategically complies with battery safety norms.
format Article
author Talele, Virendra
Moralı, Uğur
Najafi Khaboshan, Hasan
Patil, Mahesh Suresh
Panchal, Satyam
Fraser, Roydon Andrew
Fowler, Michael W.
author_facet Talele, Virendra
Moralı, Uğur
Najafi Khaboshan, Hasan
Patil, Mahesh Suresh
Panchal, Satyam
Fraser, Roydon Andrew
Fowler, Michael W.
author_sort Talele, Virendra
title Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
title_short Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
title_full Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
title_fullStr Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
title_full_unstemmed Improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
title_sort improving battery safety by utilizing composite phase change material to delay the occurrence of thermal runaway event
publisher Elsevier Ltd
publishDate 2024
url http://umpir.ump.edu.my/id/eprint/41390/1/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material.pdf
http://umpir.ump.edu.my/id/eprint/41390/2/Improving%20battery%20safety%20by%20utilizing%20composite%20phase%20change%20material%20to%20delay%20the%20occurrence%20of%20thermal%20runaway%20event_ABS.pdf
http://umpir.ump.edu.my/id/eprint/41390/
https://doi.org/10.1016/j.icheatmasstransfer.2024.107527
https://doi.org/10.1016/j.icheatmasstransfer.2024.107527
_version_ 1822924429214089216
score 13.235362