The simulation of biogas combustion in top open burner

The top open furnace is commonly used for the heating processes. The efficiency of the top open furnace is low due to the amount of heat wasted through the top open. This study was using ANSYS Fluent, a two-dimensional computational fluid dynamic (CFD) model that was used to build the top open furna...

Full description

Saved in:
Bibliographic Details
Main Authors: Selvam, A., Noor, M. M., Norhafana, M., Ihsan, C. K., Khalid, A., Mahmood, R. A., Harikrishnan, S., Nayak, S.
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2024
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/41189/1/The%20Simulation%20of%20Biogas%20Combustion%20in%20Top%20Open%20Burner.pdf
http://umpir.ump.edu.my/id/eprint/41189/
https://doi.org/10.1088/1742-6596/2688/1/012023
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.41189
record_format eprints
spelling my.ump.umpir.411892024-05-15T08:23:29Z http://umpir.ump.edu.my/id/eprint/41189/ The simulation of biogas combustion in top open burner Selvam, A. Noor, M. M. Norhafana, M. Ihsan, C. K. Khalid, A. Mahmood, R. A. Harikrishnan, S. Nayak, S. TJ Mechanical engineering and machinery The top open furnace is commonly used for the heating processes. The efficiency of the top open furnace is low due to the amount of heat wasted through the top open. This study was using ANSYS Fluent, a two-dimensional computational fluid dynamic (CFD) model that was used to build the top open furnace. Exhaust gas recirculation (EGR) was installed in the boiler in order to collect the exhaust gas and reuse it to dilute the oxygen supply. To check the combustion of low calorific gas (LCV) gas, which is biogas composed of 60% methane and 40% carbon dioxide by mass fraction, the computational study started with a standard combustion with EGR. Medium-sized mesh is used for the smoothing grid. This mesh uses inflation to enable the size of the cells and the stack element. The findings of the numerical sensitivity test show that the boundary conditions along the combustion chamber wall can affect the flame temperatures. The MILD regime was reached using biogas fuels when the right parameters were used. IOP Publishing 2024 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/41189/1/The%20Simulation%20of%20Biogas%20Combustion%20in%20Top%20Open%20Burner.pdf Selvam, A. and Noor, M. M. and Norhafana, M. and Ihsan, C. K. and Khalid, A. and Mahmood, R. A. and Harikrishnan, S. and Nayak, S. (2024) The simulation of biogas combustion in top open burner. In: Journal of Physics: Conference Series; 7th International Conference on Mechanical Engineering Research 2023 (ICMER 2023) , 12 - 13 september 2023 , Kuantan, Malaysia. pp. 1-18., 2688 (012023). ISSN 1742-6596 https://doi.org/10.1088/1742-6596/2688/1/012023
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Selvam, A.
Noor, M. M.
Norhafana, M.
Ihsan, C. K.
Khalid, A.
Mahmood, R. A.
Harikrishnan, S.
Nayak, S.
The simulation of biogas combustion in top open burner
description The top open furnace is commonly used for the heating processes. The efficiency of the top open furnace is low due to the amount of heat wasted through the top open. This study was using ANSYS Fluent, a two-dimensional computational fluid dynamic (CFD) model that was used to build the top open furnace. Exhaust gas recirculation (EGR) was installed in the boiler in order to collect the exhaust gas and reuse it to dilute the oxygen supply. To check the combustion of low calorific gas (LCV) gas, which is biogas composed of 60% methane and 40% carbon dioxide by mass fraction, the computational study started with a standard combustion with EGR. Medium-sized mesh is used for the smoothing grid. This mesh uses inflation to enable the size of the cells and the stack element. The findings of the numerical sensitivity test show that the boundary conditions along the combustion chamber wall can affect the flame temperatures. The MILD regime was reached using biogas fuels when the right parameters were used.
format Conference or Workshop Item
author Selvam, A.
Noor, M. M.
Norhafana, M.
Ihsan, C. K.
Khalid, A.
Mahmood, R. A.
Harikrishnan, S.
Nayak, S.
author_facet Selvam, A.
Noor, M. M.
Norhafana, M.
Ihsan, C. K.
Khalid, A.
Mahmood, R. A.
Harikrishnan, S.
Nayak, S.
author_sort Selvam, A.
title The simulation of biogas combustion in top open burner
title_short The simulation of biogas combustion in top open burner
title_full The simulation of biogas combustion in top open burner
title_fullStr The simulation of biogas combustion in top open burner
title_full_unstemmed The simulation of biogas combustion in top open burner
title_sort simulation of biogas combustion in top open burner
publisher IOP Publishing
publishDate 2024
url http://umpir.ump.edu.my/id/eprint/41189/1/The%20Simulation%20of%20Biogas%20Combustion%20in%20Top%20Open%20Burner.pdf
http://umpir.ump.edu.my/id/eprint/41189/
https://doi.org/10.1088/1742-6596/2688/1/012023
_version_ 1822924316319154176
score 13.23648