The simulation of biogas combustion in top open burner
The top open furnace is commonly used for the heating processes. The efficiency of the top open furnace is low due to the amount of heat wasted through the top open. This study was using ANSYS Fluent, a two-dimensional computational fluid dynamic (CFD) model that was used to build the top open furna...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2024
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/41189/1/The%20Simulation%20of%20Biogas%20Combustion%20in%20Top%20Open%20Burner.pdf http://umpir.ump.edu.my/id/eprint/41189/ https://doi.org/10.1088/1742-6596/2688/1/012023 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.41189 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.411892024-05-15T08:23:29Z http://umpir.ump.edu.my/id/eprint/41189/ The simulation of biogas combustion in top open burner Selvam, A. Noor, M. M. Norhafana, M. Ihsan, C. K. Khalid, A. Mahmood, R. A. Harikrishnan, S. Nayak, S. TJ Mechanical engineering and machinery The top open furnace is commonly used for the heating processes. The efficiency of the top open furnace is low due to the amount of heat wasted through the top open. This study was using ANSYS Fluent, a two-dimensional computational fluid dynamic (CFD) model that was used to build the top open furnace. Exhaust gas recirculation (EGR) was installed in the boiler in order to collect the exhaust gas and reuse it to dilute the oxygen supply. To check the combustion of low calorific gas (LCV) gas, which is biogas composed of 60% methane and 40% carbon dioxide by mass fraction, the computational study started with a standard combustion with EGR. Medium-sized mesh is used for the smoothing grid. This mesh uses inflation to enable the size of the cells and the stack element. The findings of the numerical sensitivity test show that the boundary conditions along the combustion chamber wall can affect the flame temperatures. The MILD regime was reached using biogas fuels when the right parameters were used. IOP Publishing 2024 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/41189/1/The%20Simulation%20of%20Biogas%20Combustion%20in%20Top%20Open%20Burner.pdf Selvam, A. and Noor, M. M. and Norhafana, M. and Ihsan, C. K. and Khalid, A. and Mahmood, R. A. and Harikrishnan, S. and Nayak, S. (2024) The simulation of biogas combustion in top open burner. In: Journal of Physics: Conference Series; 7th International Conference on Mechanical Engineering Research 2023 (ICMER 2023) , 12 - 13 september 2023 , Kuantan, Malaysia. pp. 1-18., 2688 (012023). ISSN 1742-6596 https://doi.org/10.1088/1742-6596/2688/1/012023 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Selvam, A. Noor, M. M. Norhafana, M. Ihsan, C. K. Khalid, A. Mahmood, R. A. Harikrishnan, S. Nayak, S. The simulation of biogas combustion in top open burner |
description |
The top open furnace is commonly used for the heating processes. The efficiency of the top open furnace is low due to the amount of heat wasted through the top open. This study was using ANSYS Fluent, a two-dimensional computational fluid dynamic (CFD) model that was used to build the top open furnace. Exhaust gas recirculation (EGR) was installed in the boiler in order to collect the exhaust gas and reuse it to dilute the oxygen supply. To check the combustion of low calorific gas (LCV) gas, which is biogas composed of 60% methane and 40% carbon dioxide by mass fraction, the computational study started with a standard combustion with EGR. Medium-sized mesh is used for the smoothing grid. This mesh uses inflation to enable the size of the cells and the stack element. The findings of the numerical sensitivity test show that the boundary conditions along the combustion chamber wall can affect the flame temperatures. The MILD regime was reached using biogas fuels when the right parameters were used. |
format |
Conference or Workshop Item |
author |
Selvam, A. Noor, M. M. Norhafana, M. Ihsan, C. K. Khalid, A. Mahmood, R. A. Harikrishnan, S. Nayak, S. |
author_facet |
Selvam, A. Noor, M. M. Norhafana, M. Ihsan, C. K. Khalid, A. Mahmood, R. A. Harikrishnan, S. Nayak, S. |
author_sort |
Selvam, A. |
title |
The simulation of biogas combustion in top open burner |
title_short |
The simulation of biogas combustion in top open burner |
title_full |
The simulation of biogas combustion in top open burner |
title_fullStr |
The simulation of biogas combustion in top open burner |
title_full_unstemmed |
The simulation of biogas combustion in top open burner |
title_sort |
simulation of biogas combustion in top open burner |
publisher |
IOP Publishing |
publishDate |
2024 |
url |
http://umpir.ump.edu.my/id/eprint/41189/1/The%20Simulation%20of%20Biogas%20Combustion%20in%20Top%20Open%20Burner.pdf http://umpir.ump.edu.my/id/eprint/41189/ https://doi.org/10.1088/1742-6596/2688/1/012023 |
_version_ |
1822924316319154176 |
score |
13.23648 |