Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion
Classification accuracy is essential in the bio signal’s performance-based assistive devices. In this study, surface electromyography (SEMG) signals acquisition was extracted from 3 healthy right-handed participants. SEMG signal was processed, and Motor Unit Action Potential (MUAP) was determined. A...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Seventh Sense Research Group
2022
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/40616/1/Evaluation%20of%20misclassification%20matrix%20method%20in%20validation.pdf http://umpir.ump.edu.my/id/eprint/40616/ https://doi.org/10.14445/22315381/IJETT-V70I12P225 https://doi.org/10.14445/22315381/IJETT-V70I12P225 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.40616 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.406162024-04-30T06:34:47Z http://umpir.ump.edu.my/id/eprint/40616/ Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion Mohd Hanafi, Muhammad Sidik Saiful Anwar, Che Ghani Abdul, Nasir Muhammad Nur Farhan, Saniman T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TL Motor vehicles. Aeronautics. Astronautics Classification accuracy is essential in the bio signal’s performance-based assistive devices. In this study, surface electromyography (SEMG) signals acquisition was extracted from 3 healthy right-handed participants. SEMG signal was processed, and Motor Unit Action Potential (MUAP) was determined. Accuracy, precision, sensitivity and specificity were calculated in real-time based on individual MUAP, critically compared with pattern and non-pattern recognition control methods by Misclassification Matrix inserted into Arduino MEGA 2560 Microcontroller. The results indicated that the performance of each control method is different for every participant and a comparison tool is a must to select the best out of it. It shows that the misclassification matrix filtered the best control method for participant 1 as Probability Density Function, no for participant 2 and Maximum Point Different (MPD) for participant 3 based on determined conditions. Seventh Sense Research Group 2022-12 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/40616/1/Evaluation%20of%20misclassification%20matrix%20method%20in%20validation.pdf Mohd Hanafi, Muhammad Sidik and Saiful Anwar, Che Ghani and Abdul, Nasir and Muhammad Nur Farhan, Saniman (2022) Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion. International Journal of Engineering Trends and Technology, 70 (12). pp. 272-280. ISSN 2349-0918. (Published) https://doi.org/10.14445/22315381/IJETT-V70I12P225 https://doi.org/10.14445/22315381/IJETT-V70I12P225 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TL Motor vehicles. Aeronautics. Astronautics |
spellingShingle |
T Technology (General) TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TL Motor vehicles. Aeronautics. Astronautics Mohd Hanafi, Muhammad Sidik Saiful Anwar, Che Ghani Abdul, Nasir Muhammad Nur Farhan, Saniman Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion |
description |
Classification accuracy is essential in the bio signal’s performance-based assistive devices. In this study, surface electromyography (SEMG) signals acquisition was extracted from 3 healthy right-handed participants. SEMG signal was processed, and Motor Unit Action Potential (MUAP) was determined. Accuracy, precision, sensitivity and specificity were calculated in real-time based on individual MUAP, critically compared with pattern and non-pattern recognition control methods by Misclassification Matrix inserted into Arduino MEGA 2560 Microcontroller. The results indicated that the performance of each control method is different for every participant and a comparison tool is a must to select the best out of it. It shows that the misclassification matrix filtered the best control method for participant 1 as Probability Density Function, no for participant 2 and Maximum Point Different (MPD) for participant 3 based on determined conditions. |
format |
Article |
author |
Mohd Hanafi, Muhammad Sidik Saiful Anwar, Che Ghani Abdul, Nasir Muhammad Nur Farhan, Saniman |
author_facet |
Mohd Hanafi, Muhammad Sidik Saiful Anwar, Che Ghani Abdul, Nasir Muhammad Nur Farhan, Saniman |
author_sort |
Mohd Hanafi, Muhammad Sidik |
title |
Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion |
title_short |
Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion |
title_full |
Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion |
title_fullStr |
Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion |
title_full_unstemmed |
Evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion |
title_sort |
evaluation of misclassification matrix method in validation of an assistive device for manual wheelchair propulsion |
publisher |
Seventh Sense Research Group |
publishDate |
2022 |
url |
http://umpir.ump.edu.my/id/eprint/40616/1/Evaluation%20of%20misclassification%20matrix%20method%20in%20validation.pdf http://umpir.ump.edu.my/id/eprint/40616/ https://doi.org/10.14445/22315381/IJETT-V70I12P225 https://doi.org/10.14445/22315381/IJETT-V70I12P225 |
_version_ |
1822924245322170368 |
score |
13.232432 |