Cost estimation of structural work for residential building with seismic design consideration
The Sumatra-Andaman earthquakes had triggered local earthquakes in Malaysia by reactivation of ancient inactive faults. Previously on 5th June 2015, Ranau, a region located in Sabah, Malaysia, had experienced a moderate earthquake of Mw6.1. The structural failures occurred because all existing build...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Penerbit UTHM
2023
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/40511/1/Cost%20estimation%20of%20structural%20work%20for%20residential%20building.pdf http://umpir.ump.edu.my/id/eprint/40511/2/Cost%20estimation%20of%20structural%20work%20for%20residential%20building%20with%20seismic%20design%20consideration_ABS.pdf http://umpir.ump.edu.my/id/eprint/40511/ https://doi.org/10.30880/IJIE.2023.15.02.026 https://doi.org/10.30880/IJIE.2023.15.02.026 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.40511 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.405112024-04-30T06:26:39Z http://umpir.ump.edu.my/id/eprint/40511/ Cost estimation of structural work for residential building with seismic design consideration Hanis Athirah, Roslan Nur Shairah, Zulkhibri Faisal, Ade Mohd Irwan, Adiyanto T Technology (General) TA Engineering (General). Civil engineering (General) The Sumatra-Andaman earthquakes had triggered local earthquakes in Malaysia by reactivation of ancient inactive faults. Previously on 5th June 2015, Ranau, a region located in Sabah, Malaysia, had experienced a moderate earthquake of Mw6.1. The structural failures occurred because all existing buildings only designed for gravity load without any seismic provision. Recent research work exhibits the seismic designs’ impact on the cost of material and its parameters that impact the cost. There are two types reinforced concrete residential buildings called Type 1 and Type 2 for two storey and four storey which had been used as models. This research applied four seismicity levels to the reference peak ground acceleration value, αgR = 0.07g, 0.10g, 0.13g & 0.16g, and two soil types: Soil Types B and D. The result shows that for two storey reinforced concrete residential buildings on soil types B and D, seismic design increases structural work costs, which is around 0.62% to 1.31% and 0.61% to 2.16%, respectively, for Type 1 model compared to non-seismic design. Besides, model Type 2, the increment is around 0.24% to 1.22% and 0.20% to 1.71%, respectively. Otherwise, for reinforced concrete residential building with four storey on soil types B and D, the result shows that seismic design tends to have a higher structural work’s cost around 0.41% to 2.48% and 0.98% to 11.23%, respectively, for Type 1 model. Besides, for model Type 2 the increment is around 1.80% to 2.05% and 2.34% to 8.53%, respectively, compared to non-seismic design. Penerbit UTHM 2023 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/40511/1/Cost%20estimation%20of%20structural%20work%20for%20residential%20building.pdf pdf en http://umpir.ump.edu.my/id/eprint/40511/2/Cost%20estimation%20of%20structural%20work%20for%20residential%20building%20with%20seismic%20design%20consideration_ABS.pdf Hanis Athirah, Roslan and Nur Shairah, Zulkhibri and Faisal, Ade and Mohd Irwan, Adiyanto (2023) Cost estimation of structural work for residential building with seismic design consideration. International Journal of Integrated Engineering, 15 (2). pp. 263-272. ISSN 2229-838X. (Published) https://doi.org/10.30880/IJIE.2023.15.02.026 https://doi.org/10.30880/IJIE.2023.15.02.026 |
institution |
Universiti Malaysia Pahang Al-Sultan Abdullah |
building |
UMPSA Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang Al-Sultan Abdullah |
content_source |
UMPSA Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English English |
topic |
T Technology (General) TA Engineering (General). Civil engineering (General) |
spellingShingle |
T Technology (General) TA Engineering (General). Civil engineering (General) Hanis Athirah, Roslan Nur Shairah, Zulkhibri Faisal, Ade Mohd Irwan, Adiyanto Cost estimation of structural work for residential building with seismic design consideration |
description |
The Sumatra-Andaman earthquakes had triggered local earthquakes in Malaysia by reactivation of ancient inactive faults. Previously on 5th June 2015, Ranau, a region located in Sabah, Malaysia, had experienced a moderate earthquake of Mw6.1. The structural failures occurred because all existing buildings only designed for gravity load without any seismic provision. Recent research work exhibits the seismic designs’ impact on the cost of material and its parameters that impact the cost. There are two types reinforced concrete residential buildings called Type 1 and Type 2 for two storey and four storey which had been used as models. This research applied four seismicity levels to the reference peak ground acceleration value, αgR = 0.07g, 0.10g, 0.13g & 0.16g, and two soil types: Soil Types B and D. The result shows that for two storey reinforced concrete residential buildings on soil types B and D, seismic design increases structural work costs, which is around 0.62% to 1.31% and 0.61% to 2.16%, respectively, for Type 1 model compared to non-seismic design. Besides, model Type 2, the increment is around 0.24% to 1.22% and 0.20% to 1.71%, respectively. Otherwise, for reinforced concrete residential building with four storey on soil types B and D, the result shows that seismic design tends to have a higher structural work’s cost around 0.41% to 2.48% and 0.98% to 11.23%, respectively, for Type 1 model. Besides, for model Type 2 the increment is around 1.80% to 2.05% and 2.34% to 8.53%, respectively, compared to non-seismic design. |
format |
Article |
author |
Hanis Athirah, Roslan Nur Shairah, Zulkhibri Faisal, Ade Mohd Irwan, Adiyanto |
author_facet |
Hanis Athirah, Roslan Nur Shairah, Zulkhibri Faisal, Ade Mohd Irwan, Adiyanto |
author_sort |
Hanis Athirah, Roslan |
title |
Cost estimation of structural work for residential building with seismic design consideration |
title_short |
Cost estimation of structural work for residential building with seismic design consideration |
title_full |
Cost estimation of structural work for residential building with seismic design consideration |
title_fullStr |
Cost estimation of structural work for residential building with seismic design consideration |
title_full_unstemmed |
Cost estimation of structural work for residential building with seismic design consideration |
title_sort |
cost estimation of structural work for residential building with seismic design consideration |
publisher |
Penerbit UTHM |
publishDate |
2023 |
url |
http://umpir.ump.edu.my/id/eprint/40511/1/Cost%20estimation%20of%20structural%20work%20for%20residential%20building.pdf http://umpir.ump.edu.my/id/eprint/40511/2/Cost%20estimation%20of%20structural%20work%20for%20residential%20building%20with%20seismic%20design%20consideration_ABS.pdf http://umpir.ump.edu.my/id/eprint/40511/ https://doi.org/10.30880/IJIE.2023.15.02.026 https://doi.org/10.30880/IJIE.2023.15.02.026 |
_version_ |
1822924241634328576 |
score |
13.235796 |