Cost estimation of structural work for residential building with seismic design consideration

The Sumatra-Andaman earthquakes had triggered local earthquakes in Malaysia by reactivation of ancient inactive faults. Previously on 5th June 2015, Ranau, a region located in Sabah, Malaysia, had experienced a moderate earthquake of Mw6.1. The structural failures occurred because all existing build...

Full description

Saved in:
Bibliographic Details
Main Authors: Hanis Athirah, Roslan, Nur Shairah, Zulkhibri, Faisal, Ade, Mohd Irwan, Adiyanto
Format: Article
Language:English
English
Published: Penerbit UTHM 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/40511/1/Cost%20estimation%20of%20structural%20work%20for%20residential%20building.pdf
http://umpir.ump.edu.my/id/eprint/40511/2/Cost%20estimation%20of%20structural%20work%20for%20residential%20building%20with%20seismic%20design%20consideration_ABS.pdf
http://umpir.ump.edu.my/id/eprint/40511/
https://doi.org/10.30880/IJIE.2023.15.02.026
https://doi.org/10.30880/IJIE.2023.15.02.026
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.40511
record_format eprints
spelling my.ump.umpir.405112024-04-30T06:26:39Z http://umpir.ump.edu.my/id/eprint/40511/ Cost estimation of structural work for residential building with seismic design consideration Hanis Athirah, Roslan Nur Shairah, Zulkhibri Faisal, Ade Mohd Irwan, Adiyanto T Technology (General) TA Engineering (General). Civil engineering (General) The Sumatra-Andaman earthquakes had triggered local earthquakes in Malaysia by reactivation of ancient inactive faults. Previously on 5th June 2015, Ranau, a region located in Sabah, Malaysia, had experienced a moderate earthquake of Mw6.1. The structural failures occurred because all existing buildings only designed for gravity load without any seismic provision. Recent research work exhibits the seismic designs’ impact on the cost of material and its parameters that impact the cost. There are two types reinforced concrete residential buildings called Type 1 and Type 2 for two storey and four storey which had been used as models. This research applied four seismicity levels to the reference peak ground acceleration value, αgR = 0.07g, 0.10g, 0.13g & 0.16g, and two soil types: Soil Types B and D. The result shows that for two storey reinforced concrete residential buildings on soil types B and D, seismic design increases structural work costs, which is around 0.62% to 1.31% and 0.61% to 2.16%, respectively, for Type 1 model compared to non-seismic design. Besides, model Type 2, the increment is around 0.24% to 1.22% and 0.20% to 1.71%, respectively. Otherwise, for reinforced concrete residential building with four storey on soil types B and D, the result shows that seismic design tends to have a higher structural work’s cost around 0.41% to 2.48% and 0.98% to 11.23%, respectively, for Type 1 model. Besides, for model Type 2 the increment is around 1.80% to 2.05% and 2.34% to 8.53%, respectively, compared to non-seismic design. Penerbit UTHM 2023 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/40511/1/Cost%20estimation%20of%20structural%20work%20for%20residential%20building.pdf pdf en http://umpir.ump.edu.my/id/eprint/40511/2/Cost%20estimation%20of%20structural%20work%20for%20residential%20building%20with%20seismic%20design%20consideration_ABS.pdf Hanis Athirah, Roslan and Nur Shairah, Zulkhibri and Faisal, Ade and Mohd Irwan, Adiyanto (2023) Cost estimation of structural work for residential building with seismic design consideration. International Journal of Integrated Engineering, 15 (2). pp. 263-272. ISSN 2229-838X. (Published) https://doi.org/10.30880/IJIE.2023.15.02.026 https://doi.org/10.30880/IJIE.2023.15.02.026
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Hanis Athirah, Roslan
Nur Shairah, Zulkhibri
Faisal, Ade
Mohd Irwan, Adiyanto
Cost estimation of structural work for residential building with seismic design consideration
description The Sumatra-Andaman earthquakes had triggered local earthquakes in Malaysia by reactivation of ancient inactive faults. Previously on 5th June 2015, Ranau, a region located in Sabah, Malaysia, had experienced a moderate earthquake of Mw6.1. The structural failures occurred because all existing buildings only designed for gravity load without any seismic provision. Recent research work exhibits the seismic designs’ impact on the cost of material and its parameters that impact the cost. There are two types reinforced concrete residential buildings called Type 1 and Type 2 for two storey and four storey which had been used as models. This research applied four seismicity levels to the reference peak ground acceleration value, αgR = 0.07g, 0.10g, 0.13g & 0.16g, and two soil types: Soil Types B and D. The result shows that for two storey reinforced concrete residential buildings on soil types B and D, seismic design increases structural work costs, which is around 0.62% to 1.31% and 0.61% to 2.16%, respectively, for Type 1 model compared to non-seismic design. Besides, model Type 2, the increment is around 0.24% to 1.22% and 0.20% to 1.71%, respectively. Otherwise, for reinforced concrete residential building with four storey on soil types B and D, the result shows that seismic design tends to have a higher structural work’s cost around 0.41% to 2.48% and 0.98% to 11.23%, respectively, for Type 1 model. Besides, for model Type 2 the increment is around 1.80% to 2.05% and 2.34% to 8.53%, respectively, compared to non-seismic design.
format Article
author Hanis Athirah, Roslan
Nur Shairah, Zulkhibri
Faisal, Ade
Mohd Irwan, Adiyanto
author_facet Hanis Athirah, Roslan
Nur Shairah, Zulkhibri
Faisal, Ade
Mohd Irwan, Adiyanto
author_sort Hanis Athirah, Roslan
title Cost estimation of structural work for residential building with seismic design consideration
title_short Cost estimation of structural work for residential building with seismic design consideration
title_full Cost estimation of structural work for residential building with seismic design consideration
title_fullStr Cost estimation of structural work for residential building with seismic design consideration
title_full_unstemmed Cost estimation of structural work for residential building with seismic design consideration
title_sort cost estimation of structural work for residential building with seismic design consideration
publisher Penerbit UTHM
publishDate 2023
url http://umpir.ump.edu.my/id/eprint/40511/1/Cost%20estimation%20of%20structural%20work%20for%20residential%20building.pdf
http://umpir.ump.edu.my/id/eprint/40511/2/Cost%20estimation%20of%20structural%20work%20for%20residential%20building%20with%20seismic%20design%20consideration_ABS.pdf
http://umpir.ump.edu.my/id/eprint/40511/
https://doi.org/10.30880/IJIE.2023.15.02.026
https://doi.org/10.30880/IJIE.2023.15.02.026
_version_ 1822924241634328576
score 13.235796