Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation

The generation of harmonics during application of AC and DC magnetic fields to multicore iron oxide particles in low concentration solutions was studied based on magnetization curve and harmonics response of the nanoparticles in low concentration solutions. As a first step, the distribution of parti...

全面介紹

Saved in:
書目詳細資料
Main Authors: Mohd Mawardi, Saari, Saifudin, Razali, Amir Izzani, Mohamed, Hamdan, Daniyal, Hamzah, Ahmad, Sutjipto, Agus Geter Edy, Nazatul Sharreena, Suhaimi, Muhammad Hafiz, Mazwir
格式: Research Book Profile
語言:English
出版: 2016
主題:
在線閱讀:http://umpir.ump.edu.my/id/eprint/36249/1/Investigating%20the%20magnetic%20fluid%20characteristics%20in%20low%20concentration%20solutions%20to%20enhance%20harmonics%20generation.pdf
http://umpir.ump.edu.my/id/eprint/36249/
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.ump.umpir.36249
record_format eprints
spelling my.ump.umpir.362492023-01-04T02:09:33Z http://umpir.ump.edu.my/id/eprint/36249/ Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation Mohd Mawardi, Saari Saifudin, Razali Amir Izzani, Mohamed Hamdan, Daniyal Hamzah, Ahmad Sutjipto, Agus Geter Edy Nazatul Sharreena, Suhaimi Muhammad Hafiz, Mazwir TK Electrical engineering. Electronics Nuclear engineering The generation of harmonics during application of AC and DC magnetic fields to multicore iron oxide particles in low concentration solutions was studied based on magnetization curve and harmonics response of the nanoparticles in low concentration solutions. As a first step, the distribution of particle size was analyzed using a Non- Negative Inversion Method to investigate the relation between particle size and diamagnetic contribution of liquid carrier. The harmonics of nanoparticle solutions was evaluated using a highly sensitive AC susceptometer, which was developed during this research period. Based on harmonics response, distribution of particle size, and the derived models of AC susceptibility response, the fundamental harmonic generation was affected by the diamagnetic contribution when the iron concentration was lower than 6 microg/ml.. 2016 Research Book Profile NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/36249/1/Investigating%20the%20magnetic%20fluid%20characteristics%20in%20low%20concentration%20solutions%20to%20enhance%20harmonics%20generation.pdf Mohd Mawardi, Saari and Saifudin, Razali and Amir Izzani, Mohamed and Hamdan, Daniyal and Hamzah, Ahmad and Sutjipto, Agus Geter Edy and Nazatul Sharreena, Suhaimi and Muhammad Hafiz, Mazwir (2016) Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation. , [Research Book Profile: Research Report] (Unpublished)
institution Universiti Malaysia Pahang Al-Sultan Abdullah
building UMPSA Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang Al-Sultan Abdullah
content_source UMPSA Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Mohd Mawardi, Saari
Saifudin, Razali
Amir Izzani, Mohamed
Hamdan, Daniyal
Hamzah, Ahmad
Sutjipto, Agus Geter Edy
Nazatul Sharreena, Suhaimi
Muhammad Hafiz, Mazwir
Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation
description The generation of harmonics during application of AC and DC magnetic fields to multicore iron oxide particles in low concentration solutions was studied based on magnetization curve and harmonics response of the nanoparticles in low concentration solutions. As a first step, the distribution of particle size was analyzed using a Non- Negative Inversion Method to investigate the relation between particle size and diamagnetic contribution of liquid carrier. The harmonics of nanoparticle solutions was evaluated using a highly sensitive AC susceptometer, which was developed during this research period. Based on harmonics response, distribution of particle size, and the derived models of AC susceptibility response, the fundamental harmonic generation was affected by the diamagnetic contribution when the iron concentration was lower than 6 microg/ml..
format Research Book Profile
author Mohd Mawardi, Saari
Saifudin, Razali
Amir Izzani, Mohamed
Hamdan, Daniyal
Hamzah, Ahmad
Sutjipto, Agus Geter Edy
Nazatul Sharreena, Suhaimi
Muhammad Hafiz, Mazwir
author_facet Mohd Mawardi, Saari
Saifudin, Razali
Amir Izzani, Mohamed
Hamdan, Daniyal
Hamzah, Ahmad
Sutjipto, Agus Geter Edy
Nazatul Sharreena, Suhaimi
Muhammad Hafiz, Mazwir
author_sort Mohd Mawardi, Saari
title Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation
title_short Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation
title_full Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation
title_fullStr Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation
title_full_unstemmed Investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation
title_sort investigating the magnetic fluid characteristics in low concentration solutions to enhance harmonics generation
publishDate 2016
url http://umpir.ump.edu.my/id/eprint/36249/1/Investigating%20the%20magnetic%20fluid%20characteristics%20in%20low%20concentration%20solutions%20to%20enhance%20harmonics%20generation.pdf
http://umpir.ump.edu.my/id/eprint/36249/
_version_ 1822923139564175360
score 13.251813