Optical goniometer for continuous knee monitoring application based on linear array photodiode
Health monitoring devices have received great interests by researchers in sensor and instrumentation field. Knee monitoring application is one of the most popular topic in this area due to the importance of the knee joint in human’s daily activities. Many non-optical for the knee monitoring applicat...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2022
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/34787/1/Optical%20goniometer%20for%20continuous%20knee%20monitoring%20application%20based%20on%20linear%20array%20photodiode.pdf http://umpir.ump.edu.my/id/eprint/34787/ https://doi.org/10.1016/j.ijleo.2022.169384 https://doi.org/10.1016/j.ijleo.2022.169384 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.34787 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.347872022-07-27T01:32:58Z http://umpir.ump.edu.my/id/eprint/34787/ Optical goniometer for continuous knee monitoring application based on linear array photodiode G. M., Salim M. A., Zawawi RD Surgery TK Electrical engineering. Electronics Nuclear engineering Health monitoring devices have received great interests by researchers in sensor and instrumentation field. Knee monitoring application is one of the most popular topic in this area due to the importance of the knee joint in human’s daily activities. Many non-optical for the knee monitoring application share common limitations including sensitive to temperature variation and signal drift. For optical-based goniometers, they have limited working range due to the optical characteristics of the fiber. In this paper, we propose an optical-based goniometer with mechanical assembly which has a working range between 0 and 160 degree in flexion direction. Moreover, it has a resolution of 0.08 degree, accuracy of 0.04 degree as well as independent to temperature variation. Initial study to demonstrate the range of detection angle of the proposed sensor have been carried out to validate the theoretical design of the sensor. Further analysis on the reliability of the sensor under different operators as well as the consistency of the measurement output under repetitive usage will be presented in separate reports. Elsevier 2022 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/34787/1/Optical%20goniometer%20for%20continuous%20knee%20monitoring%20application%20based%20on%20linear%20array%20photodiode.pdf G. M., Salim and M. A., Zawawi (2022) Optical goniometer for continuous knee monitoring application based on linear array photodiode. Optik, 264. pp. 1-12. ISSN 0030-4026 https://doi.org/10.1016/j.ijleo.2022.169384 https://doi.org/10.1016/j.ijleo.2022.169384 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
RD Surgery TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
RD Surgery TK Electrical engineering. Electronics Nuclear engineering G. M., Salim M. A., Zawawi Optical goniometer for continuous knee monitoring application based on linear array photodiode |
description |
Health monitoring devices have received great interests by researchers in sensor and instrumentation field. Knee monitoring application is one of the most popular topic in this area due to the importance of the knee joint in human’s daily activities. Many non-optical for the knee monitoring application share common limitations including sensitive to temperature variation and signal drift. For optical-based goniometers, they have limited working range due to the optical characteristics of the fiber. In this paper, we propose an optical-based goniometer with mechanical assembly which has a working range between 0 and 160 degree in flexion direction. Moreover, it has a resolution of 0.08 degree, accuracy of 0.04 degree as well as independent to temperature variation. Initial study to demonstrate the range of detection angle of the proposed sensor have been carried out to validate the theoretical design of the sensor. Further analysis on the reliability of the sensor under different operators as well as the consistency of the measurement output under repetitive usage will be presented in separate reports. |
format |
Article |
author |
G. M., Salim M. A., Zawawi |
author_facet |
G. M., Salim M. A., Zawawi |
author_sort |
G. M., Salim |
title |
Optical goniometer for continuous knee monitoring application based on linear array photodiode |
title_short |
Optical goniometer for continuous knee monitoring application based on linear array photodiode |
title_full |
Optical goniometer for continuous knee monitoring application based on linear array photodiode |
title_fullStr |
Optical goniometer for continuous knee monitoring application based on linear array photodiode |
title_full_unstemmed |
Optical goniometer for continuous knee monitoring application based on linear array photodiode |
title_sort |
optical goniometer for continuous knee monitoring application based on linear array photodiode |
publisher |
Elsevier |
publishDate |
2022 |
url |
http://umpir.ump.edu.my/id/eprint/34787/1/Optical%20goniometer%20for%20continuous%20knee%20monitoring%20application%20based%20on%20linear%20array%20photodiode.pdf http://umpir.ump.edu.my/id/eprint/34787/ https://doi.org/10.1016/j.ijleo.2022.169384 https://doi.org/10.1016/j.ijleo.2022.169384 |
_version_ |
1739828269250772992 |
score |
13.211869 |