Experimental study on oleochemical waste as partial cement replacement

Waste materials are no more a useless substances since many of the industries turn it into a functional materials for their product. Environment have suffered enough by the existence of the waste materials that are not properly disposed. Hence the attention is on the reuse of the waste material. Ole...

Full description

Saved in:
Bibliographic Details
Main Author: Lily Diyana, Kamarudzaman
Format: Undergraduates Project Papers
Language:English
Published: 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/29703/1/Experimental%20study%20on%20oleochemical%20waste%20as%20partial%20cement%20replacement.pdf
http://umpir.ump.edu.my/id/eprint/29703/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.29703
record_format eprints
spelling my.ump.umpir.297032023-03-29T07:14:52Z http://umpir.ump.edu.my/id/eprint/29703/ Experimental study on oleochemical waste as partial cement replacement Lily Diyana, Kamarudzaman TA Engineering (General). Civil engineering (General) Waste materials are no more a useless substances since many of the industries turn it into a functional materials for their product. Environment have suffered enough by the existence of the waste materials that are not properly disposed. Hence the attention is on the reuse of the waste material. Oleochemical waste can be one of the waste materials that has potential for replacement material in the concrete. For this study, oleochemical waste comes in semi-solid or sludge to partially replace the cement in the concrete mixture. This sludge is dried oven to remove the moisture. In order to get fine particles size, the sludge is grinded. The mixtures are prepared using 5% and 10% replacement of sludge in concrete G25. The dimension of the cubes used for compressive strength test is 100mm x 100mm and 100mm x 100mm x 650mm of prisms are used for flexural strength test. Compressive strength and flexural strength test are conducted to determine the strength of the concrete at 7 and 28 days. Water absorption test was carried out at 28 days to get the water absorbed by sludge concrete to determine the property of absorbing water when concrete are emerged in the water. It can be conclude, at all test conducted, the percentage of sludge added may give the poor result compare to the conventional concrete mixture. 2019-05 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/29703/1/Experimental%20study%20on%20oleochemical%20waste%20as%20partial%20cement%20replacement.pdf Lily Diyana, Kamarudzaman (2019) Experimental study on oleochemical waste as partial cement replacement. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Lily Diyana, Kamarudzaman
Experimental study on oleochemical waste as partial cement replacement
description Waste materials are no more a useless substances since many of the industries turn it into a functional materials for their product. Environment have suffered enough by the existence of the waste materials that are not properly disposed. Hence the attention is on the reuse of the waste material. Oleochemical waste can be one of the waste materials that has potential for replacement material in the concrete. For this study, oleochemical waste comes in semi-solid or sludge to partially replace the cement in the concrete mixture. This sludge is dried oven to remove the moisture. In order to get fine particles size, the sludge is grinded. The mixtures are prepared using 5% and 10% replacement of sludge in concrete G25. The dimension of the cubes used for compressive strength test is 100mm x 100mm and 100mm x 100mm x 650mm of prisms are used for flexural strength test. Compressive strength and flexural strength test are conducted to determine the strength of the concrete at 7 and 28 days. Water absorption test was carried out at 28 days to get the water absorbed by sludge concrete to determine the property of absorbing water when concrete are emerged in the water. It can be conclude, at all test conducted, the percentage of sludge added may give the poor result compare to the conventional concrete mixture.
format Undergraduates Project Papers
author Lily Diyana, Kamarudzaman
author_facet Lily Diyana, Kamarudzaman
author_sort Lily Diyana, Kamarudzaman
title Experimental study on oleochemical waste as partial cement replacement
title_short Experimental study on oleochemical waste as partial cement replacement
title_full Experimental study on oleochemical waste as partial cement replacement
title_fullStr Experimental study on oleochemical waste as partial cement replacement
title_full_unstemmed Experimental study on oleochemical waste as partial cement replacement
title_sort experimental study on oleochemical waste as partial cement replacement
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/29703/1/Experimental%20study%20on%20oleochemical%20waste%20as%20partial%20cement%20replacement.pdf
http://umpir.ump.edu.my/id/eprint/29703/
_version_ 1762392391561510912
score 13.211869