Axial load of built-up sigma section cold formed steel with hole

The objective of this paper is to determine the maximum load of open built-up steel and to study the built-up sigma section cold-formed steel with hole. Cold-formed steel commonly used as compression members to carry heavier loads. The column specimens were compressed between bearing plate with flat...

Full description

Saved in:
Bibliographic Details
Main Author: Nuradibah, Mohammad Zin
Format: Undergraduates Project Papers
Language:English
Published: 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/29682/1/02.Axial%20load%20of%20built-up%20sigma%20section%20cold%20formed%20steel%20with%20hole.PDF
http://umpir.ump.edu.my/id/eprint/29682/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.29682
record_format eprints
spelling my.ump.umpir.296822023-05-11T04:10:43Z http://umpir.ump.edu.my/id/eprint/29682/ Axial load of built-up sigma section cold formed steel with hole Nuradibah, Mohammad Zin TA Engineering (General). Civil engineering (General) The objective of this paper is to determine the maximum load of open built-up steel and to study the built-up sigma section cold-formed steel with hole. Cold-formed steel commonly used as compression members to carry heavier loads. The column specimens were compressed between bearing plate with flat ends. Two series of E-section will be used which is BE103-2.0 and also BE203-2.0. All specimens with same height of 600 mm with two without opening and the other 6 with different position of openings from support. The shape of openings that have been used for all specimen is same which is elongated. This experiment is testing by using Universal Testing Machine (UTM). During the experiment, three transducers is used and been located at the specimen. The function of transducer is to read the displacement of the specimen during testing where the graph had been plotted. The opening distance from the support and specimen without opening will show a difference of the results. After the test, local buckling and distortional buckling can be seen at the specimen. Most of the specimen without opening shows the maximum load compared to the specimen with opening. 2019-05 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/29682/1/02.Axial%20load%20of%20built-up%20sigma%20section%20cold%20formed%20steel%20with%20hole.PDF Nuradibah, Mohammad Zin (2019) Axial load of built-up sigma section cold formed steel with hole. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Nuradibah, Mohammad Zin
Axial load of built-up sigma section cold formed steel with hole
description The objective of this paper is to determine the maximum load of open built-up steel and to study the built-up sigma section cold-formed steel with hole. Cold-formed steel commonly used as compression members to carry heavier loads. The column specimens were compressed between bearing plate with flat ends. Two series of E-section will be used which is BE103-2.0 and also BE203-2.0. All specimens with same height of 600 mm with two without opening and the other 6 with different position of openings from support. The shape of openings that have been used for all specimen is same which is elongated. This experiment is testing by using Universal Testing Machine (UTM). During the experiment, three transducers is used and been located at the specimen. The function of transducer is to read the displacement of the specimen during testing where the graph had been plotted. The opening distance from the support and specimen without opening will show a difference of the results. After the test, local buckling and distortional buckling can be seen at the specimen. Most of the specimen without opening shows the maximum load compared to the specimen with opening.
format Undergraduates Project Papers
author Nuradibah, Mohammad Zin
author_facet Nuradibah, Mohammad Zin
author_sort Nuradibah, Mohammad Zin
title Axial load of built-up sigma section cold formed steel with hole
title_short Axial load of built-up sigma section cold formed steel with hole
title_full Axial load of built-up sigma section cold formed steel with hole
title_fullStr Axial load of built-up sigma section cold formed steel with hole
title_full_unstemmed Axial load of built-up sigma section cold formed steel with hole
title_sort axial load of built-up sigma section cold formed steel with hole
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/29682/1/02.Axial%20load%20of%20built-up%20sigma%20section%20cold%20formed%20steel%20with%20hole.PDF
http://umpir.ump.edu.my/id/eprint/29682/
_version_ 1768006850296414208
score 13.211869