Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions
This study investigates the performance of thin-film cadmium telluride (CdTe) building integrated photovoltaic (BIPV) arrays (façade and roof) under tropical weather conditions in Malaysia. This investigation observed the variation in performance ratio (PR) for each façade oriented in different dire...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor & Francis
2019
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/28473/1/Performance%20evaluation%20of%20CdTe%20BIPV%20roof%20and%20fa%C3%A7ades%20.pdf http://umpir.ump.edu.my/id/eprint/28473/ https://doi.org/10.1080/15567036.2019.1602216 https://doi.org/10.1080/15567036.2019.1602216 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.28473 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.284732021-01-26T03:38:39Z http://umpir.ump.edu.my/id/eprint/28473/ Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions Kumar, Nallapaneni Manoj Sudhakar, K. Samykano, M. TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics This study investigates the performance of thin-film cadmium telluride (CdTe) building integrated photovoltaic (BIPV) arrays (façade and roof) under tropical weather conditions in Malaysia. This investigation observed the variation in performance ratio (PR) for each façade oriented in different directions and the roof. Average annual PR for 7 kW flat roof, 2.3 kW façade in east and west, and 5.5 kW façade in north are 76.26%, 71%, 70.53%, and 66.42%, respectively, and corresponding energy losses are −23.6%, −28.8%, −29.4%, and −33.6%. It is identified that a façade oriented in north direction performs lower when compared to other façades and the roof. Taylor & Francis 2019-04-08 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/28473/1/Performance%20evaluation%20of%20CdTe%20BIPV%20roof%20and%20fa%C3%A7ades%20.pdf Kumar, Nallapaneni Manoj and Sudhakar, K. and Samykano, M. (2019) Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions. Energy Sources, Part A: Recovery, Utilization, and Environmental Effects, 42 (9). pp. 1057-1071. ISSN 1556-7036 (Print); 1556-7230 (Online) https://doi.org/10.1080/15567036.2019.1602216 https://doi.org/10.1080/15567036.2019.1602216 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics |
spellingShingle |
TJ Mechanical engineering and machinery TL Motor vehicles. Aeronautics. Astronautics Kumar, Nallapaneni Manoj Sudhakar, K. Samykano, M. Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions |
description |
This study investigates the performance of thin-film cadmium telluride (CdTe) building integrated photovoltaic (BIPV) arrays (façade and roof) under tropical weather conditions in Malaysia. This investigation observed the variation in performance ratio (PR) for each façade oriented in different directions and the roof. Average annual PR for 7 kW flat roof, 2.3 kW façade in east and west, and 5.5 kW façade in north are 76.26%, 71%, 70.53%, and 66.42%, respectively, and corresponding energy losses are −23.6%, −28.8%, −29.4%, and −33.6%. It is identified that a façade oriented in north direction performs lower when compared to other façades and the roof. |
format |
Article |
author |
Kumar, Nallapaneni Manoj Sudhakar, K. Samykano, M. |
author_facet |
Kumar, Nallapaneni Manoj Sudhakar, K. Samykano, M. |
author_sort |
Kumar, Nallapaneni Manoj |
title |
Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions |
title_short |
Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions |
title_full |
Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions |
title_fullStr |
Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions |
title_full_unstemmed |
Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions |
title_sort |
performance evaluation of cdte bipv roof and façades in tropical weather conditions |
publisher |
Taylor & Francis |
publishDate |
2019 |
url |
http://umpir.ump.edu.my/id/eprint/28473/1/Performance%20evaluation%20of%20CdTe%20BIPV%20roof%20and%20fa%C3%A7ades%20.pdf http://umpir.ump.edu.my/id/eprint/28473/ https://doi.org/10.1080/15567036.2019.1602216 https://doi.org/10.1080/15567036.2019.1602216 |
_version_ |
1690371140456808448 |
score |
13.211869 |