Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy

Wear on Co-Cr-Mo biomedical implants is still a major issue especially for applications in articulation joints like in total ankle, knee and hip arthroplasty. Generation of excessive wear particles can coagulate in body tissues which later cause inflammation, bone loss and necrosis. Modification of...

Full description

Saved in:
Bibliographic Details
Main Authors: S., Izman, M. A., Hassan, Mas Ayu, Hassan, Mohammed Rafiq, Abdul Kadir, Mohammed Ruslan, Abdullah, Mahmood, Anwar, A., Shah, R., Daud
Format: Article
Language:English
Published: Trans Tech Publications, Switzerland 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/28110/1/Effect%20of%20pretreatment%20process%20on%20thermal%20oxidation%20of%20biomedical%20.pdf
http://umpir.ump.edu.my/id/eprint/28110/
https://doi.org/10.4028/www.scientific.net/AMR.399-401.1564
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.28110
record_format eprints
spelling my.ump.umpir.281102020-05-05T07:53:22Z http://umpir.ump.edu.my/id/eprint/28110/ Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy S., Izman M. A., Hassan Mas Ayu, Hassan Mohammed Rafiq, Abdul Kadir Mohammed Ruslan, Abdullah Mahmood, Anwar A., Shah R., Daud T Technology (General) TJ Mechanical engineering and machinery Wear on Co-Cr-Mo biomedical implants is still a major issue especially for applications in articulation joints like in total ankle, knee and hip arthroplasty. Generation of excessive wear particles can coagulate in body tissues which later cause inflammation, bone loss and necrosis. Modification of implant surfaces is a common technique for increasing the hardness and thus minimizing these effects. In this study, thermal oxidation method was carried out on the Co-Cr-Mo to investigate the effects of different pretreatment processes and surface roughness on the hardness of oxide layer formed. Prior to oxidation process, all samples were annealed and pickled to remove residual stress and oxide scales respectively. The oxidation process was done inside furnace under atmospheric condition for 3 hours at 1160 °C. The metallic compositions, surface morphology and hardness of the oxide layer formed on the substrate were verified using X-ray diffraction (XRD), scanning electron microscope and micro-Vickers hardness analysis respectively. It is found that mechanical pretreatment provides oxide/carbide layer with higher hardness than chemical pretreatment method. It is believed that remnants of polishing diamond pastes trapped in roughness valleys react with metal matrix and later transform into carbides during oxidation process. In contrast, initial surface roughness of the substrate has no significant effect on the hardness of oxide/carbide layer. Trans Tech Publications, Switzerland 2012 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/28110/1/Effect%20of%20pretreatment%20process%20on%20thermal%20oxidation%20of%20biomedical%20.pdf S., Izman and M. A., Hassan and Mas Ayu, Hassan and Mohammed Rafiq, Abdul Kadir and Mohammed Ruslan, Abdullah and Mahmood, Anwar and A., Shah and R., Daud (2012) Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy. Advanced Materials Research, 399-401. pp. 1564-1567. ISSN 1022-6680 (print), 1662-8985 (online) https://doi.org/10.4028/www.scientific.net/AMR.399-401.1564
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
S., Izman
M. A., Hassan
Mas Ayu, Hassan
Mohammed Rafiq, Abdul Kadir
Mohammed Ruslan, Abdullah
Mahmood, Anwar
A., Shah
R., Daud
Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy
description Wear on Co-Cr-Mo biomedical implants is still a major issue especially for applications in articulation joints like in total ankle, knee and hip arthroplasty. Generation of excessive wear particles can coagulate in body tissues which later cause inflammation, bone loss and necrosis. Modification of implant surfaces is a common technique for increasing the hardness and thus minimizing these effects. In this study, thermal oxidation method was carried out on the Co-Cr-Mo to investigate the effects of different pretreatment processes and surface roughness on the hardness of oxide layer formed. Prior to oxidation process, all samples were annealed and pickled to remove residual stress and oxide scales respectively. The oxidation process was done inside furnace under atmospheric condition for 3 hours at 1160 °C. The metallic compositions, surface morphology and hardness of the oxide layer formed on the substrate were verified using X-ray diffraction (XRD), scanning electron microscope and micro-Vickers hardness analysis respectively. It is found that mechanical pretreatment provides oxide/carbide layer with higher hardness than chemical pretreatment method. It is believed that remnants of polishing diamond pastes trapped in roughness valleys react with metal matrix and later transform into carbides during oxidation process. In contrast, initial surface roughness of the substrate has no significant effect on the hardness of oxide/carbide layer.
format Article
author S., Izman
M. A., Hassan
Mas Ayu, Hassan
Mohammed Rafiq, Abdul Kadir
Mohammed Ruslan, Abdullah
Mahmood, Anwar
A., Shah
R., Daud
author_facet S., Izman
M. A., Hassan
Mas Ayu, Hassan
Mohammed Rafiq, Abdul Kadir
Mohammed Ruslan, Abdullah
Mahmood, Anwar
A., Shah
R., Daud
author_sort S., Izman
title Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy
title_short Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy
title_full Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy
title_fullStr Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy
title_full_unstemmed Effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy
title_sort effect of pretreatment process on thermal oxidation of biomedical grade cobalt based alloy
publisher Trans Tech Publications, Switzerland
publishDate 2012
url http://umpir.ump.edu.my/id/eprint/28110/1/Effect%20of%20pretreatment%20process%20on%20thermal%20oxidation%20of%20biomedical%20.pdf
http://umpir.ump.edu.my/id/eprint/28110/
https://doi.org/10.4028/www.scientific.net/AMR.399-401.1564
_version_ 1669007764800667648
score 13.211869