Finite element method study: the effect of insertion torque and angle on pedicle screw loosening

Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae. However screw loosening is a major problem of spine fusion, contribu...

Full description

Saved in:
Bibliographic Details
Main Authors: Rosdi, Daud, M., Syakir, Mas Ayu, Hassan, Arman Shah, Abdullah
Format: Conference or Workshop Item
Language:English
English
Published: Universiti Malaysia Pahang 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/27646/1/6.%20Finite%20element%20method%20study%20-%20the%20effect%20of%20insertion.pdf
http://umpir.ump.edu.my/id/eprint/27646/2/6.1%20Finite%20element%20method%20study%20-%20the%20effect%20of%20insertion.pdf
http://umpir.ump.edu.my/id/eprint/27646/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.27646
record_format eprints
spelling my.ump.umpir.276462020-02-03T06:44:08Z http://umpir.ump.edu.my/id/eprint/27646/ Finite element method study: the effect of insertion torque and angle on pedicle screw loosening Rosdi, Daud M., Syakir Mas Ayu, Hassan Arman Shah, Abdullah TJ Mechanical engineering and machinery Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae. However screw loosening is a major problem of spine fusion, contributing to delayed patient recovery. This appears to be a minor problem for fixation and fusion of healthy, non-osteoporotic bone. Screw loosening happen when insertion torque and angle that are not suitable for pedicle screw which affected the screw pullout strength. Based on optimum torque and angle in finite element analysis, loosening of screw in spine fusion can be minimized by increasing the screw pullout strength. The highest of pull out strength can minor the loosening of screw. Four insertion angle of pedicle screw were used which are 0°, 10°, 20° and 30°. Besides that, effect of insertion torque on pullout strength can be seen on Equivalent von Mises stress value when applied three value of moment to pedicle screw-bone with constant of insertion angle. The lowest stress for pedicle screw can give a better fixation with bone and thus can increase the pullout strength. We found that the insertion angle 10° give higher pullout strength of pedicle screw-synthetic bone which indirectly will minimizing the effect of the screw loosening from bone. Besides that, insertion torque with 1200 Nm give a lower Equivalent von Mises stress which it cause the less effect on fixation between screw and bone and thus has potential in minimizing the loosening to pedicle screw. Universiti Malaysia Pahang 2019 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/27646/1/6.%20Finite%20element%20method%20study%20-%20the%20effect%20of%20insertion.pdf pdf en http://umpir.ump.edu.my/id/eprint/27646/2/6.1%20Finite%20element%20method%20study%20-%20the%20effect%20of%20insertion.pdf Rosdi, Daud and M., Syakir and Mas Ayu, Hassan and Arman Shah, Abdullah (2019) Finite element method study: the effect of insertion torque and angle on pedicle screw loosening. In: The 4th International Conference on Frontiers of Composite Materials, 13 - 16 November 2019 , The University of Queensland, Brisbane, Australia. pp. 1-10.. (Unpublished)
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Rosdi, Daud
M., Syakir
Mas Ayu, Hassan
Arman Shah, Abdullah
Finite element method study: the effect of insertion torque and angle on pedicle screw loosening
description Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae. However screw loosening is a major problem of spine fusion, contributing to delayed patient recovery. This appears to be a minor problem for fixation and fusion of healthy, non-osteoporotic bone. Screw loosening happen when insertion torque and angle that are not suitable for pedicle screw which affected the screw pullout strength. Based on optimum torque and angle in finite element analysis, loosening of screw in spine fusion can be minimized by increasing the screw pullout strength. The highest of pull out strength can minor the loosening of screw. Four insertion angle of pedicle screw were used which are 0°, 10°, 20° and 30°. Besides that, effect of insertion torque on pullout strength can be seen on Equivalent von Mises stress value when applied three value of moment to pedicle screw-bone with constant of insertion angle. The lowest stress for pedicle screw can give a better fixation with bone and thus can increase the pullout strength. We found that the insertion angle 10° give higher pullout strength of pedicle screw-synthetic bone which indirectly will minimizing the effect of the screw loosening from bone. Besides that, insertion torque with 1200 Nm give a lower Equivalent von Mises stress which it cause the less effect on fixation between screw and bone and thus has potential in minimizing the loosening to pedicle screw.
format Conference or Workshop Item
author Rosdi, Daud
M., Syakir
Mas Ayu, Hassan
Arman Shah, Abdullah
author_facet Rosdi, Daud
M., Syakir
Mas Ayu, Hassan
Arman Shah, Abdullah
author_sort Rosdi, Daud
title Finite element method study: the effect of insertion torque and angle on pedicle screw loosening
title_short Finite element method study: the effect of insertion torque and angle on pedicle screw loosening
title_full Finite element method study: the effect of insertion torque and angle on pedicle screw loosening
title_fullStr Finite element method study: the effect of insertion torque and angle on pedicle screw loosening
title_full_unstemmed Finite element method study: the effect of insertion torque and angle on pedicle screw loosening
title_sort finite element method study: the effect of insertion torque and angle on pedicle screw loosening
publisher Universiti Malaysia Pahang
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/27646/1/6.%20Finite%20element%20method%20study%20-%20the%20effect%20of%20insertion.pdf
http://umpir.ump.edu.my/id/eprint/27646/2/6.1%20Finite%20element%20method%20study%20-%20the%20effect%20of%20insertion.pdf
http://umpir.ump.edu.my/id/eprint/27646/
_version_ 1662754777385140224
score 13.211869