Low insertion loss of surface mount device low pass filter at 700 MHz

The paper involved with the design, simulation and fabrication of 6th order elliptical-based Surface Mount Device (SMD) LPF with cutoff frequency at 700 MHz. Fabricated LPF is consisted of four PCB layers which components of SMD are soldered on the top layer. Another three layers is for grounding an...

Full description

Saved in:
Bibliographic Details
Main Authors: Khairil Anuar, Khairi, Mohd Faizal, Jamlos, Surentiran, Padmanathan, Mohd Aminudin, Jamlos, Muammar, Mohamad Isa
Format: Article
Language:English
Published: IAES 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/26188/1/Low%20insertion%20loss%20of%20surface%20mount%20device%20low.pdf
http://umpir.ump.edu.my/id/eprint/26188/
https://doi.org/10.11591/eei.v8i2.1386
https://doi.org/10.11591/eei.v8i2.1386
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.26188
record_format eprints
spelling my.ump.umpir.261882019-12-06T08:57:00Z http://umpir.ump.edu.my/id/eprint/26188/ Low insertion loss of surface mount device low pass filter at 700 MHz Khairil Anuar, Khairi Mohd Faizal, Jamlos Surentiran, Padmanathan Mohd Aminudin, Jamlos Muammar, Mohamad Isa TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering The paper involved with the design, simulation and fabrication of 6th order elliptical-based Surface Mount Device (SMD) LPF with cutoff frequency at 700 MHz. Fabricated LPF is consisted of four PCB layers which components of SMD are soldered on the top layer. Another three layers is for grounding and shielding, power supply and grounding void. The four layers is crucial to avoid interference between components. The research has find out that the momentum simulation is definitely required to improve the signals response compared to a normal simulation by ADS software. The comparison between momentum simulated versus measured and normal simulated versus measured is 0.2 dB and 29 dB correspondingly. Such huge difference leads to conclusion that momentum simulation is saving time without having much struggles and efforts to get optimum readings. The Proposed SMD LPF has a very low insertion loss of 0.965dB with a transition region of 195 MHz which is good steepness to avoid any image frequency. IAES 2019-06 Article PeerReviewed pdf en cc_by_nc_4 http://umpir.ump.edu.my/id/eprint/26188/1/Low%20insertion%20loss%20of%20surface%20mount%20device%20low.pdf Khairil Anuar, Khairi and Mohd Faizal, Jamlos and Surentiran, Padmanathan and Mohd Aminudin, Jamlos and Muammar, Mohamad Isa (2019) Low insertion loss of surface mount device low pass filter at 700 MHz. Bulletin of Electrical Engineering and Informatics, 8 (2). pp. 382-388. ISSN 2302-9285 https://doi.org/10.11591/eei.v8i2.1386 https://doi.org/10.11591/eei.v8i2.1386
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
Khairil Anuar, Khairi
Mohd Faizal, Jamlos
Surentiran, Padmanathan
Mohd Aminudin, Jamlos
Muammar, Mohamad Isa
Low insertion loss of surface mount device low pass filter at 700 MHz
description The paper involved with the design, simulation and fabrication of 6th order elliptical-based Surface Mount Device (SMD) LPF with cutoff frequency at 700 MHz. Fabricated LPF is consisted of four PCB layers which components of SMD are soldered on the top layer. Another three layers is for grounding and shielding, power supply and grounding void. The four layers is crucial to avoid interference between components. The research has find out that the momentum simulation is definitely required to improve the signals response compared to a normal simulation by ADS software. The comparison between momentum simulated versus measured and normal simulated versus measured is 0.2 dB and 29 dB correspondingly. Such huge difference leads to conclusion that momentum simulation is saving time without having much struggles and efforts to get optimum readings. The Proposed SMD LPF has a very low insertion loss of 0.965dB with a transition region of 195 MHz which is good steepness to avoid any image frequency.
format Article
author Khairil Anuar, Khairi
Mohd Faizal, Jamlos
Surentiran, Padmanathan
Mohd Aminudin, Jamlos
Muammar, Mohamad Isa
author_facet Khairil Anuar, Khairi
Mohd Faizal, Jamlos
Surentiran, Padmanathan
Mohd Aminudin, Jamlos
Muammar, Mohamad Isa
author_sort Khairil Anuar, Khairi
title Low insertion loss of surface mount device low pass filter at 700 MHz
title_short Low insertion loss of surface mount device low pass filter at 700 MHz
title_full Low insertion loss of surface mount device low pass filter at 700 MHz
title_fullStr Low insertion loss of surface mount device low pass filter at 700 MHz
title_full_unstemmed Low insertion loss of surface mount device low pass filter at 700 MHz
title_sort low insertion loss of surface mount device low pass filter at 700 mhz
publisher IAES
publishDate 2019
url http://umpir.ump.edu.my/id/eprint/26188/1/Low%20insertion%20loss%20of%20surface%20mount%20device%20low.pdf
http://umpir.ump.edu.my/id/eprint/26188/
https://doi.org/10.11591/eei.v8i2.1386
https://doi.org/10.11591/eei.v8i2.1386
_version_ 1654960230522421248
score 13.211869