A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling
When there are sudden changes in fluid propagation in the pipeline system, pressure transient signal is generated. Due to the rapid pressure and fluctuation flow of the system such as opening and closing of valve rapidly. A few group of researchers had use the pressure transient signal to detect and...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2019
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/24512/1/A%20Study%20of%20Ikaz%20and%20Normalized%20Hilbert%20transform%20for%20solving%20faulty%20in%20pipeline%20distribution%20system%20using%20transmission%20line%20modelling.pdf http://umpir.ump.edu.my/id/eprint/24512/ https://doi.org/10.1088/1757-899X/469/1/012083 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.24512 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.245122019-10-14T03:45:24Z http://umpir.ump.edu.my/id/eprint/24512/ A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling Hanafi, M. Yusop M. F., Ghazali Azmi, W. H. Mohd Fadhlan, Mohd Yusof M. A., Pi Remli M. A. A., Rahim TJ Mechanical engineering and machinery When there are sudden changes in fluid propagation in the pipeline system, pressure transient signal is generated. Due to the rapid pressure and fluctuation flow of the system such as opening and closing of valve rapidly. A few group of researchers had use the pressure transient signal to detect and locate any uncertainties in the system (leak and blockage). Empirical Mode decomposition (EMD) will be as the demonizing method of pressure transient signal before proceeding to be analyzed further by using instantaneous frequency analysis in this research. EMD might be the step of decomposing the signal into intrinsic mode function, but this method have difficulties in selecting a suitable IMF. This paper proposed the uses of Integrated Kurtosis-based Algorithm for z-filter Technique (Ikaz) for that allows automatic selection of suitable and relevant IMF. This work shows the artificial pressure transient signal generates using transmission line modelling (TLM) in order to test the effectiveness of Ikaz as the autonomous selection of IMF. This paper implements the Normalize Hilbert Transform (NHT) as the instantaneous frequency analysis. A straight fluid network was designed using TLM fixing with higher resistance at some point that act as a leak and connecting to the pipe feature such as junction, pipefitting or blockage. The analysis results using Ikaz show that the method can be implement as an automatic selection of intrinsic mode function (IMF) with percentage errors below 5%. Thus, Ikaz-kurtosis ratio is recommended to be implemented as automatic selection of intrinsic mode function (IMF) through NHT analysis. IOP Publishing 2019-01 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/24512/1/A%20Study%20of%20Ikaz%20and%20Normalized%20Hilbert%20transform%20for%20solving%20faulty%20in%20pipeline%20distribution%20system%20using%20transmission%20line%20modelling.pdf Hanafi, M. Yusop and M. F., Ghazali and Azmi, W. H. and Mohd Fadhlan, Mohd Yusof and M. A., Pi Remli and M. A. A., Rahim (2019) A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling. In: 1st International Postgraduate Conference on Mechanical Engineering, IPCME 2018, 31 October 2018 , UMP Library, Pekan. pp. 1-10., 469 (012083). ISSN 1757-899X https://doi.org/10.1088/1757-899X/469/1/012083 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Hanafi, M. Yusop M. F., Ghazali Azmi, W. H. Mohd Fadhlan, Mohd Yusof M. A., Pi Remli M. A. A., Rahim A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling |
description |
When there are sudden changes in fluid propagation in the pipeline system, pressure transient signal is generated. Due to the rapid pressure and fluctuation flow of the system such as opening and closing of valve rapidly. A few group of researchers had use the pressure transient signal to detect and locate any uncertainties in the system (leak and blockage). Empirical Mode decomposition (EMD) will be as the demonizing method of pressure transient signal before proceeding to be analyzed further by using instantaneous frequency analysis in this research. EMD might be the step of decomposing the signal into intrinsic mode function, but this method have difficulties in selecting a suitable IMF. This paper proposed the uses of Integrated Kurtosis-based Algorithm for z-filter Technique (Ikaz) for that allows automatic selection of suitable and relevant IMF. This work shows the artificial pressure transient signal generates using transmission line modelling (TLM) in order to test the effectiveness of Ikaz as the autonomous selection of IMF. This paper implements the Normalize Hilbert Transform (NHT) as the instantaneous frequency analysis. A straight fluid network was designed using TLM fixing with higher resistance at some point that act as a leak and connecting to the pipe feature such as junction, pipefitting or blockage. The analysis results using Ikaz show that the method can be implement as an automatic selection of intrinsic mode function (IMF) with percentage errors below 5%. Thus, Ikaz-kurtosis ratio is recommended to be implemented as automatic selection of intrinsic mode function (IMF) through NHT analysis. |
format |
Conference or Workshop Item |
author |
Hanafi, M. Yusop M. F., Ghazali Azmi, W. H. Mohd Fadhlan, Mohd Yusof M. A., Pi Remli M. A. A., Rahim |
author_facet |
Hanafi, M. Yusop M. F., Ghazali Azmi, W. H. Mohd Fadhlan, Mohd Yusof M. A., Pi Remli M. A. A., Rahim |
author_sort |
Hanafi, M. Yusop |
title |
A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling |
title_short |
A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling |
title_full |
A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling |
title_fullStr |
A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling |
title_full_unstemmed |
A Study of Ikaz and Normalized Hilbert transform for solving faulty in pipeline distribution system using transmission line modelling |
title_sort |
study of ikaz and normalized hilbert transform for solving faulty in pipeline distribution system using transmission line modelling |
publisher |
IOP Publishing |
publishDate |
2019 |
url |
http://umpir.ump.edu.my/id/eprint/24512/1/A%20Study%20of%20Ikaz%20and%20Normalized%20Hilbert%20transform%20for%20solving%20faulty%20in%20pipeline%20distribution%20system%20using%20transmission%20line%20modelling.pdf http://umpir.ump.edu.my/id/eprint/24512/ https://doi.org/10.1088/1757-899X/469/1/012083 |
_version_ |
1648741160276983808 |
score |
13.211869 |