In this work, a diaphragm-type Fibre Bragg grating (FBG) dynamic pressure transducer was designed and developed. Pressure transducer in this study consists of elastic thin metal diaphragm which acts as a primary sensing element; and integrated with an FBG sensor for the secondary sensing element. In...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2017
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/21054/1/Development%20of%20Fibre%20Bragg%20grating%20%28FBG%29%20dynamic%20pressure%20transducer%20with%20diminutive%20voltage%20inconsistency.pdf http://umpir.ump.edu.my/id/eprint/21054/ https://doi.org/10.1088/1757-899X/257/1/012080 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.21054 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.210542019-11-07T04:08:13Z http://umpir.ump.edu.my/id/eprint/21054/ Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency A. M., Aizzuddin Z. M., Hafizi Kee, L. V. Vorathin, E. Lim, Kok Sing TJ Mechanical engineering and machinery In this work, a diaphragm-type Fibre Bragg grating (FBG) dynamic pressure transducer was designed and developed. Pressure transducer in this study consists of elastic thin metal diaphragm which acts as a primary sensing element; and integrated with an FBG sensor for the secondary sensing element. In the common match filter interrogation system, converting optical signal to voltage is the challenging due to voltage reading inconsistency, which would cause variation in pressure reading. New alternative arrangements of matched filter interrogation system are used to address the issue. For automated pressure measurement, the optical signal from FBG was converted into voltage by using the proposed arrangement of matched filter interrogation system. Additional FBG was added as reference sensor which installed in the system for detection the change of broadband light source. Reduction of voltage inconsistency was achieved by normalizing the voltage reading from sensor with the voltage reading from reference FBG. The result shows that the FBG pressure transducer is proven to be suitable for pressure measurement of gas or liquid with an average error of 5.348%. Furthermore, the FBG sensor has a good linearity with a linear correlation coefficient of 97.29% in pressure measurement. IOP Publishing 2017-11 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/21054/1/Development%20of%20Fibre%20Bragg%20grating%20%28FBG%29%20dynamic%20pressure%20transducer%20with%20diminutive%20voltage%20inconsistency.pdf A. M., Aizzuddin and Z. M., Hafizi and Kee, L. V. and Vorathin, E. and Lim, Kok Sing (2017) Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency. In: IOP Conference Series: Materials Science and Engineering, 4th International Conference on Mechanical Engineering Research, ICMER 2017, 1-2 August 2017 , The Swiss Garden Beach Resort, Kuantan. pp. 1-10., 257 (012080). ISSN 1757-899X https://doi.org/10.1088/1757-899X/257/1/012080 DOI: 10.1088/1757-899X/257/1/012080 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery A. M., Aizzuddin Z. M., Hafizi Kee, L. V. Vorathin, E. Lim, Kok Sing Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency |
description |
In this work, a diaphragm-type Fibre Bragg grating (FBG) dynamic pressure transducer was designed and developed. Pressure transducer in this study consists of elastic thin metal diaphragm which acts as a primary sensing element; and integrated with an FBG sensor for the secondary sensing element. In the common match filter interrogation system, converting optical signal to voltage is the challenging due to voltage reading inconsistency, which would cause variation in pressure reading. New alternative arrangements of matched filter interrogation system are used to address the issue. For automated pressure measurement, the optical signal from FBG was converted into voltage by using the proposed arrangement of matched filter interrogation system. Additional FBG was added as reference sensor which installed in the system for detection the change of broadband light source. Reduction of voltage inconsistency was achieved by normalizing the voltage reading from sensor with the voltage reading from reference FBG. The result shows that the FBG pressure transducer is proven to be suitable for pressure measurement of gas or liquid with an average error of 5.348%. Furthermore, the FBG sensor has a good linearity with a linear correlation coefficient of 97.29% in pressure measurement. |
format |
Conference or Workshop Item |
author |
A. M., Aizzuddin Z. M., Hafizi Kee, L. V. Vorathin, E. Lim, Kok Sing |
author_facet |
A. M., Aizzuddin Z. M., Hafizi Kee, L. V. Vorathin, E. Lim, Kok Sing |
author_sort |
A. M., Aizzuddin |
title |
Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency |
title_short |
Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency |
title_full |
Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency |
title_fullStr |
Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency |
title_full_unstemmed |
Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency |
title_sort |
development of fibre bragg grating (fbg) dynamic pressure transducer with diminutive voltage inconsistency |
publisher |
IOP Publishing |
publishDate |
2017 |
url |
http://umpir.ump.edu.my/id/eprint/21054/1/Development%20of%20Fibre%20Bragg%20grating%20%28FBG%29%20dynamic%20pressure%20transducer%20with%20diminutive%20voltage%20inconsistency.pdf http://umpir.ump.edu.my/id/eprint/21054/ https://doi.org/10.1088/1757-899X/257/1/012080 |
_version_ |
1651866903738580992 |
score |
13.211869 |