Physicochemical characteristics of fine coarse particles in indoor building

An experimental study was conducted to investigate the physicochemical characteristics of fine and coarse particles as the major pollutants that may post risks to human health in the indoor workplace building of chemical company which located in Gebeng, Kuantan. The objectives of this study are to m...

Full description

Saved in:
Bibliographic Details
Main Author: Teh, Joe Ean
Format: Undergraduates Project Papers
Language:English
Published: 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/13465/1/FTECH%20-%20TEH%20JOE%20EAN.PDF
http://umpir.ump.edu.my/id/eprint/13465/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.13465
record_format eprints
spelling my.ump.umpir.134652022-02-18T14:50:02Z http://umpir.ump.edu.my/id/eprint/13465/ Physicochemical characteristics of fine coarse particles in indoor building Teh, Joe Ean Q Science (General) TA Engineering (General). Civil engineering (General) An experimental study was conducted to investigate the physicochemical characteristics of fine and coarse particles as the major pollutants that may post risks to human health in the indoor workplace building of chemical company which located in Gebeng, Kuantan. The objectives of this study are to measure the concentration level of particles, to assess the heavy metals concentration which associated with particles, and to investigate the relationship of the concentration level of particles in the indoor and outdoor workplace building of chemical company. A walkthrough observation was conducted in order to study the layout building, to define the exposure zones for conducting sampling in the building, to obtain the basic information on the factors that may affect indoor air quality and identifying the sources of the potential contaminants. The concentration level of particles was collected by using a very fast response hand-held instrument and the heavy metal which associated with fine and coarse particles was analysed by using Inductively Coupled Plasma- Mass Spectrometry (ICP-MS). The results of concentration level of particles was compared with the WHO Guideline of Indoor Air Quality for Particulate Matter and US-EPA Standard for particulate matter. It shows that the concentration level of fine particles at location B of workplace building of chemical company is not complied with WHO Guideline of Indoor Air Quality for Particulate Matter. In addition, the concentration levels of coarse particles at three points A, B, and C are not complied with both WHO guideline and US-EPA Standard. While only the concentration level of coarse particle at location D is complied with the standard limits that stated in US-EPA guidelines. For the outdoor environment, both fine and coarse particles concentration levels are complied with the National Ambient Air Quality Standard (NAAQS). Apart from this, it was found that six heavy metals such as Al, Si, Se, Co, Ba, and Ga which associated with fine and coarse particles in the indoor and outdoor environment of the workplace building of chemical company. Some control measures were proposed in order to minimize the concentration level of fine and coarse particles in the indoor building such as removing the pollutants by houseplants, isolating the photocopier machine and printers in a good ventilation room, vacuuming cleaning frequently with correct way, exchange the filter of air condition from time to time, and conducting IAQ assessment frequently. 2015-01 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/13465/1/FTECH%20-%20TEH%20JOE%20EAN.PDF Teh, Joe Ean (2015) Physicochemical characteristics of fine coarse particles in indoor building. Faculty of Engineering Technology, Universiti Malaysia Pahang.
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic Q Science (General)
TA Engineering (General). Civil engineering (General)
spellingShingle Q Science (General)
TA Engineering (General). Civil engineering (General)
Teh, Joe Ean
Physicochemical characteristics of fine coarse particles in indoor building
description An experimental study was conducted to investigate the physicochemical characteristics of fine and coarse particles as the major pollutants that may post risks to human health in the indoor workplace building of chemical company which located in Gebeng, Kuantan. The objectives of this study are to measure the concentration level of particles, to assess the heavy metals concentration which associated with particles, and to investigate the relationship of the concentration level of particles in the indoor and outdoor workplace building of chemical company. A walkthrough observation was conducted in order to study the layout building, to define the exposure zones for conducting sampling in the building, to obtain the basic information on the factors that may affect indoor air quality and identifying the sources of the potential contaminants. The concentration level of particles was collected by using a very fast response hand-held instrument and the heavy metal which associated with fine and coarse particles was analysed by using Inductively Coupled Plasma- Mass Spectrometry (ICP-MS). The results of concentration level of particles was compared with the WHO Guideline of Indoor Air Quality for Particulate Matter and US-EPA Standard for particulate matter. It shows that the concentration level of fine particles at location B of workplace building of chemical company is not complied with WHO Guideline of Indoor Air Quality for Particulate Matter. In addition, the concentration levels of coarse particles at three points A, B, and C are not complied with both WHO guideline and US-EPA Standard. While only the concentration level of coarse particle at location D is complied with the standard limits that stated in US-EPA guidelines. For the outdoor environment, both fine and coarse particles concentration levels are complied with the National Ambient Air Quality Standard (NAAQS). Apart from this, it was found that six heavy metals such as Al, Si, Se, Co, Ba, and Ga which associated with fine and coarse particles in the indoor and outdoor environment of the workplace building of chemical company. Some control measures were proposed in order to minimize the concentration level of fine and coarse particles in the indoor building such as removing the pollutants by houseplants, isolating the photocopier machine and printers in a good ventilation room, vacuuming cleaning frequently with correct way, exchange the filter of air condition from time to time, and conducting IAQ assessment frequently.
format Undergraduates Project Papers
author Teh, Joe Ean
author_facet Teh, Joe Ean
author_sort Teh, Joe Ean
title Physicochemical characteristics of fine coarse particles in indoor building
title_short Physicochemical characteristics of fine coarse particles in indoor building
title_full Physicochemical characteristics of fine coarse particles in indoor building
title_fullStr Physicochemical characteristics of fine coarse particles in indoor building
title_full_unstemmed Physicochemical characteristics of fine coarse particles in indoor building
title_sort physicochemical characteristics of fine coarse particles in indoor building
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/13465/1/FTECH%20-%20TEH%20JOE%20EAN.PDF
http://umpir.ump.edu.my/id/eprint/13465/
_version_ 1725972838225018880
score 13.211869