Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography
In this work, we aim to analyse the capability of using a 16-segmented Electrical Capacitance Tomography (ECT) sensor system to monitor the internal composition of a chemical process conveyor that carries crude palm oil (CPO) multiphase flow. The source used to excite the electrodes is a differentia...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier Ltd
2016
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/13398/1/Analysis%20of%20Crude%20Palm%20Oil%20Composition%20in%20a%20Chemical%20Process%20Conveyor%20using%20Electrical%20Capacitance%20Tomography.pdf http://umpir.ump.edu.my/id/eprint/13398/ http://dx.doi.org/10.1016/j.flowmeasinst.2016.06.011 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.ump.umpir.13398 |
---|---|
record_format |
eprints |
spelling |
my.ump.umpir.133982018-02-14T01:45:04Z http://umpir.ump.edu.my/id/eprint/13398/ Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography E. J., Mohamad Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman H. L. M., Ameran Yasmin, Abdul Wahab O. M. F., Marwah TK Electrical engineering. Electronics Nuclear engineering In this work, we aim to analyse the capability of using a 16-segmented Electrical Capacitance Tomography (ECT) sensor system to monitor the internal composition of a chemical process conveyor that carries crude palm oil (CPO) multiphase flow. The source used to excite the electrodes is a differential potential, instead of the conventional single potential source, in order to obtain an improved sensitivity of the sensor, especially in the central area of the pipe. This system aims to recognise the phase concentration of the flow. The attained concentration profile that is received from the capacitance measurements is capable of providing an image of the liquid and liquid mixture in the pipeline, making the separation process (between oil and liquid waste) much easier and the CPO's quality can be dependably monitored. Experimental results and analysis are presented, and the new excitation technique is shown to provide better sensor sensitivity in the central pipe area. The visualisation results deliver information regarding the flow regime and concentration distribution in a two-phase flow-rate measurement system incorporating a liquid flow-measuring device. The information obtained will assist the design of process equipment, and the verification of existing computational modelling and simulation techniques. Elsevier Ltd 2016 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/13398/1/Analysis%20of%20Crude%20Palm%20Oil%20Composition%20in%20a%20Chemical%20Process%20Conveyor%20using%20Electrical%20Capacitance%20Tomography.pdf E. J., Mohamad and Ruzairi, Abdul Rahim and Mohd Hafiz, Fazalul Rahiman and H. L. M., Ameran and Yasmin, Abdul Wahab and O. M. F., Marwah (2016) Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography. Flow Measurement and Instrumentation, 50. pp. 57-64. ISSN 0955-5986 http://dx.doi.org/10.1016/j.flowmeasinst.2016.06.011 DOI: 10.1016/j.flowmeasinst.2016.06.011 |
institution |
Universiti Malaysia Pahang |
building |
UMP Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaysia Pahang |
content_source |
UMP Institutional Repository |
url_provider |
http://umpir.ump.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering E. J., Mohamad Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman H. L. M., Ameran Yasmin, Abdul Wahab O. M. F., Marwah Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography |
description |
In this work, we aim to analyse the capability of using a 16-segmented Electrical Capacitance Tomography (ECT) sensor system to monitor the internal composition of a chemical process conveyor that carries crude palm oil (CPO) multiphase flow. The source used to excite the electrodes is a differential potential, instead of the conventional single potential source, in order to obtain an improved sensitivity of the sensor, especially in the central area of the pipe. This system aims to recognise the phase concentration of the flow. The attained concentration profile that is received from the capacitance measurements is capable of providing an image of the liquid and liquid mixture in the pipeline, making the separation process (between oil and liquid waste) much easier and the CPO's quality can be dependably monitored. Experimental results and analysis are presented, and the new excitation technique is shown to provide better sensor sensitivity in the central pipe area. The visualisation results deliver information regarding the flow regime and concentration distribution in a two-phase flow-rate measurement system incorporating a liquid flow-measuring device. The information obtained will assist the design of process equipment, and the verification of existing computational modelling and simulation techniques. |
format |
Article |
author |
E. J., Mohamad Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman H. L. M., Ameran Yasmin, Abdul Wahab O. M. F., Marwah |
author_facet |
E. J., Mohamad Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman H. L. M., Ameran Yasmin, Abdul Wahab O. M. F., Marwah |
author_sort |
E. J., Mohamad |
title |
Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography |
title_short |
Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography |
title_full |
Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography |
title_fullStr |
Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography |
title_full_unstemmed |
Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography |
title_sort |
analysis of crude palm oil composition in a chemical process conveyor using electrical capacitance tomography |
publisher |
Elsevier Ltd |
publishDate |
2016 |
url |
http://umpir.ump.edu.my/id/eprint/13398/1/Analysis%20of%20Crude%20Palm%20Oil%20Composition%20in%20a%20Chemical%20Process%20Conveyor%20using%20Electrical%20Capacitance%20Tomography.pdf http://umpir.ump.edu.my/id/eprint/13398/ http://dx.doi.org/10.1016/j.flowmeasinst.2016.06.011 |
_version_ |
1643667152224387072 |
score |
13.211869 |