Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography

In this work, we aim to analyse the capability of using a 16-segmented Electrical Capacitance Tomography (ECT) sensor system to monitor the internal composition of a chemical process conveyor that carries crude palm oil (CPO) multiphase flow. The source used to excite the electrodes is a differentia...

Full description

Saved in:
Bibliographic Details
Main Authors: E. J., Mohamad, Ruzairi, Abdul Rahim, Mohd Hafiz, Fazalul Rahiman, H. L. M., Ameran, Yasmin, Abdul Wahab, O. M. F., Marwah
Format: Article
Language:English
Published: Elsevier Ltd 2016
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/13398/1/Analysis%20of%20Crude%20Palm%20Oil%20Composition%20in%20a%20Chemical%20Process%20Conveyor%20using%20Electrical%20Capacitance%20Tomography.pdf
http://umpir.ump.edu.my/id/eprint/13398/
http://dx.doi.org/10.1016/j.flowmeasinst.2016.06.011
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.ump.umpir.13398
record_format eprints
spelling my.ump.umpir.133982018-02-14T01:45:04Z http://umpir.ump.edu.my/id/eprint/13398/ Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography E. J., Mohamad Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman H. L. M., Ameran Yasmin, Abdul Wahab O. M. F., Marwah TK Electrical engineering. Electronics Nuclear engineering In this work, we aim to analyse the capability of using a 16-segmented Electrical Capacitance Tomography (ECT) sensor system to monitor the internal composition of a chemical process conveyor that carries crude palm oil (CPO) multiphase flow. The source used to excite the electrodes is a differential potential, instead of the conventional single potential source, in order to obtain an improved sensitivity of the sensor, especially in the central area of the pipe. This system aims to recognise the phase concentration of the flow. The attained concentration profile that is received from the capacitance measurements is capable of providing an image of the liquid and liquid mixture in the pipeline, making the separation process (between oil and liquid waste) much easier and the CPO's quality can be dependably monitored. Experimental results and analysis are presented, and the new excitation technique is shown to provide better sensor sensitivity in the central pipe area. The visualisation results deliver information regarding the flow regime and concentration distribution in a two-phase flow-rate measurement system incorporating a liquid flow-measuring device. The information obtained will assist the design of process equipment, and the verification of existing computational modelling and simulation techniques. Elsevier Ltd 2016 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/13398/1/Analysis%20of%20Crude%20Palm%20Oil%20Composition%20in%20a%20Chemical%20Process%20Conveyor%20using%20Electrical%20Capacitance%20Tomography.pdf E. J., Mohamad and Ruzairi, Abdul Rahim and Mohd Hafiz, Fazalul Rahiman and H. L. M., Ameran and Yasmin, Abdul Wahab and O. M. F., Marwah (2016) Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography. Flow Measurement and Instrumentation, 50. pp. 57-64. ISSN 0955-5986 http://dx.doi.org/10.1016/j.flowmeasinst.2016.06.011 DOI: 10.1016/j.flowmeasinst.2016.06.011
institution Universiti Malaysia Pahang
building UMP Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Pahang
content_source UMP Institutional Repository
url_provider http://umpir.ump.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
E. J., Mohamad
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
H. L. M., Ameran
Yasmin, Abdul Wahab
O. M. F., Marwah
Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography
description In this work, we aim to analyse the capability of using a 16-segmented Electrical Capacitance Tomography (ECT) sensor system to monitor the internal composition of a chemical process conveyor that carries crude palm oil (CPO) multiphase flow. The source used to excite the electrodes is a differential potential, instead of the conventional single potential source, in order to obtain an improved sensitivity of the sensor, especially in the central area of the pipe. This system aims to recognise the phase concentration of the flow. The attained concentration profile that is received from the capacitance measurements is capable of providing an image of the liquid and liquid mixture in the pipeline, making the separation process (between oil and liquid waste) much easier and the CPO's quality can be dependably monitored. Experimental results and analysis are presented, and the new excitation technique is shown to provide better sensor sensitivity in the central pipe area. The visualisation results deliver information regarding the flow regime and concentration distribution in a two-phase flow-rate measurement system incorporating a liquid flow-measuring device. The information obtained will assist the design of process equipment, and the verification of existing computational modelling and simulation techniques.
format Article
author E. J., Mohamad
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
H. L. M., Ameran
Yasmin, Abdul Wahab
O. M. F., Marwah
author_facet E. J., Mohamad
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
H. L. M., Ameran
Yasmin, Abdul Wahab
O. M. F., Marwah
author_sort E. J., Mohamad
title Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography
title_short Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography
title_full Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography
title_fullStr Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography
title_full_unstemmed Analysis of Crude Palm Oil Composition in a Chemical Process Conveyor using Electrical Capacitance Tomography
title_sort analysis of crude palm oil composition in a chemical process conveyor using electrical capacitance tomography
publisher Elsevier Ltd
publishDate 2016
url http://umpir.ump.edu.my/id/eprint/13398/1/Analysis%20of%20Crude%20Palm%20Oil%20Composition%20in%20a%20Chemical%20Process%20Conveyor%20using%20Electrical%20Capacitance%20Tomography.pdf
http://umpir.ump.edu.my/id/eprint/13398/
http://dx.doi.org/10.1016/j.flowmeasinst.2016.06.011
_version_ 1643667152224387072
score 13.211869