Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system

The production of aquaculture has a great potential and high demand in the Asia country. The production of aquaculture is increased with a good water quality in the fish pond. A good water quality must be maintained and monitored by using the smart water monitoring system which is a real-time measur...

Full description

Saved in:
Bibliographic Details
Main Author: Tang, Chia Ling
Format: Undergraduate Final Project Report
Published: 2019
Online Access:http://discol.umk.edu.my/id/eprint/4845/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.umk.eprints.4845
record_format eprints
spelling my.umk.eprints.48452022-05-23T08:35:50Z http://discol.umk.edu.my/id/eprint/4845/ Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system Tang, Chia Ling The production of aquaculture has a great potential and high demand in the Asia country. The production of aquaculture is increased with a good water quality in the fish pond. A good water quality must be maintained and monitored by using the smart water monitoring system which is a real-time measurement to assess and monitor the status of water quality regularly, to obtain the real-time data at any time and anywhere. This system gives early short warning notification through phone message. The purpose of this study is to evaluate and estimate the relationship between nitrate and dissolved oxygen by using the correlation and regression analyses in Statistic Package for Social Science (SPSS) software. The data are collected by the sensor and sent to the computer for assessing and analysing the data. In the result, the smart water monitoring system is verified with the portable water quality equipment due to both readings are approximately similar with each other. The finding of the study is the higher the dissolved oxygen, the lower the nitrate in the fish pond. The result of correlation analysis showed that there is a strong negative correlation and significant relationship between nitrate and dissolved oxygen with p-value is lower than 0.01 and 0.05. In the overall result of regression analysis, 99.3% of the behaviour of nitrate can be explained and predicted by dissolved oxygen. Most of the assumptions of regression analysis are met which is considered as the regression model is fitted with the data. Therefore, there is the impact of nitrate on the dissolved oxygen in the fish pond. 2019 Undergraduate Final Project Report NonPeerReviewed Tang, Chia Ling (2019) Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system. Final Year Project thesis, Universiti Malaysia Kelantan. (Submitted)
institution Universiti Malaysia Kelantan
building Perpustakaan Universiti Malaysia Kelantan
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaysia Kelantan
content_source UMK Institutional Repository
url_provider http://umkeprints.umk.edu.my/
description The production of aquaculture has a great potential and high demand in the Asia country. The production of aquaculture is increased with a good water quality in the fish pond. A good water quality must be maintained and monitored by using the smart water monitoring system which is a real-time measurement to assess and monitor the status of water quality regularly, to obtain the real-time data at any time and anywhere. This system gives early short warning notification through phone message. The purpose of this study is to evaluate and estimate the relationship between nitrate and dissolved oxygen by using the correlation and regression analyses in Statistic Package for Social Science (SPSS) software. The data are collected by the sensor and sent to the computer for assessing and analysing the data. In the result, the smart water monitoring system is verified with the portable water quality equipment due to both readings are approximately similar with each other. The finding of the study is the higher the dissolved oxygen, the lower the nitrate in the fish pond. The result of correlation analysis showed that there is a strong negative correlation and significant relationship between nitrate and dissolved oxygen with p-value is lower than 0.01 and 0.05. In the overall result of regression analysis, 99.3% of the behaviour of nitrate can be explained and predicted by dissolved oxygen. Most of the assumptions of regression analysis are met which is considered as the regression model is fitted with the data. Therefore, there is the impact of nitrate on the dissolved oxygen in the fish pond.
format Undergraduate Final Project Report
author Tang, Chia Ling
spellingShingle Tang, Chia Ling
Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system
author_facet Tang, Chia Ling
author_sort Tang, Chia Ling
title Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system
title_short Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system
title_full Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system
title_fullStr Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system
title_full_unstemmed Analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system
title_sort analysis of nitrate and dissolved oxygen on fish ponds based on smart water monitoring system
publishDate 2019
url http://discol.umk.edu.my/id/eprint/4845/
_version_ 1763303471038070784
score 13.211869