Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li

Automatic Generation Control (AGC) is used for regulating the electrical power supply in two-area power system and changing the system frequency and tie-line load. The performance of AGC has to be tuned properly so that the performance can be optimized. In this project, modified evolutionary particl...

Full description

Saved in:
Bibliographic Details
Main Author: Lu , Li
Format: Thesis
Published: 2018
Subjects:
Online Access:http://studentsrepo.um.edu.my/9614/1/Lu_Li.jpg
http://studentsrepo.um.edu.my/9614/8/Report_LULI.pdf
http://studentsrepo.um.edu.my/9614/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.stud.9614
record_format eprints
spelling my.um.stud.96142021-03-02T00:37:10Z Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li Lu , Li TK Electrical engineering. Electronics Nuclear engineering Automatic Generation Control (AGC) is used for regulating the electrical power supply in two-area power system and changing the system frequency and tie-line load. The performance of AGC has to be tuned properly so that the performance can be optimized. In this project, modified evolutionary particle swarm optimisation (MEPSO) -time varying acceleration coefficient (TVAC) is proposed for an AGC of two-area power system to optimize its performance by tuning parameters of the PID controllers. Comparison of the performance by using the proposed algorithm and other algorithms was made to identify which algorithm is better in controlling the performance of the AGC. The AGC in two-area power system was constructed and simulated by using MATLAB R2017b software. From the simulation results, it was found that with the same number of PID controllers, the performance of AGC optimised by using MEPSO-TVAC algorithm is better in terms of overshoot and fitness value than using EPSO and PSO algorithms. Also, using MEPSO-TVAC algorithm, the performance of AGC by using two PID controllers is better in terms of rise time and settling time than using one PID controller. Therefore, via implementation of optimisation method, the performance of AGC can be improved by varying the parameters of PID controller. 2018-08 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/9614/1/Lu_Li.jpg application/pdf http://studentsrepo.um.edu.my/9614/8/Report_LULI.pdf Lu , Li (2018) Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/9614/
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Student Repository
url_provider http://studentsrepo.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Lu , Li
Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li
description Automatic Generation Control (AGC) is used for regulating the electrical power supply in two-area power system and changing the system frequency and tie-line load. The performance of AGC has to be tuned properly so that the performance can be optimized. In this project, modified evolutionary particle swarm optimisation (MEPSO) -time varying acceleration coefficient (TVAC) is proposed for an AGC of two-area power system to optimize its performance by tuning parameters of the PID controllers. Comparison of the performance by using the proposed algorithm and other algorithms was made to identify which algorithm is better in controlling the performance of the AGC. The AGC in two-area power system was constructed and simulated by using MATLAB R2017b software. From the simulation results, it was found that with the same number of PID controllers, the performance of AGC optimised by using MEPSO-TVAC algorithm is better in terms of overshoot and fitness value than using EPSO and PSO algorithms. Also, using MEPSO-TVAC algorithm, the performance of AGC by using two PID controllers is better in terms of rise time and settling time than using one PID controller. Therefore, via implementation of optimisation method, the performance of AGC can be improved by varying the parameters of PID controller.
format Thesis
author Lu , Li
author_facet Lu , Li
author_sort Lu , Li
title Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li
title_short Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li
title_full Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li
title_fullStr Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li
title_full_unstemmed Optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / Lu Li
title_sort optimisation of automatic generation control performance in two-area power system with pid controllers using mepso / lu li
publishDate 2018
url http://studentsrepo.um.edu.my/9614/1/Lu_Li.jpg
http://studentsrepo.um.edu.my/9614/8/Report_LULI.pdf
http://studentsrepo.um.edu.my/9614/
_version_ 1738506283745542144