Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming

This research project presents the idea of campus building energy optimization strategies according to the nature of building and occupants’ activities. World have been experiencing rapid growth for last few decades and thus cause the energy consumption rise drastically. Therefore, the objectives of...

Full description

Saved in:
Bibliographic Details
Main Author: Chin, Yi Ming
Format: Thesis
Published: 2018
Subjects:
Online Access:http://studentsrepo.um.edu.my/9558/1/Chin_Yi_Ming.jpg
http://studentsrepo.um.edu.my/9558/8/Research_Report_Final.pdf
http://studentsrepo.um.edu.my/9558/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.stud.9558
record_format eprints
spelling my.um.stud.95582021-01-26T22:19:23Z Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming Chin, Yi Ming T Technology (General) TJ Mechanical engineering and machinery This research project presents the idea of campus building energy optimization strategies according to the nature of building and occupants’ activities. World have been experiencing rapid growth for last few decades and thus cause the energy consumption rise drastically. Therefore, the objectives of this research are to propose the energy optimization approaches: set-point temperature and tinted window for campus building. The approaches were built according to the target building characteristic and focus and thermal consumption only. Energy consumption of the target building was simulated using energy simulation software (EnergyPlus) and the result was compared. The approaches proposed were verified using the software respectively. Simulation result shows that both approaches had successfully reduced the total building energy consumption by reducing HVAC system energy consumption. Set-point temperature reduced the annual energy consumption by 10.05% whereas tinted window would reduce the annual energy consumption by 3.25%. The results proved that the two optimization strategies could effectively reduce the cooling load and total energy consumption of the campus building. 2018-07 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/9558/1/Chin_Yi_Ming.jpg application/pdf http://studentsrepo.um.edu.my/9558/8/Research_Report_Final.pdf Chin, Yi Ming (2018) Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming. Masters thesis, University of Malaya. http://studentsrepo.um.edu.my/9558/
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Student Repository
url_provider http://studentsrepo.um.edu.my/
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Chin, Yi Ming
Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming
description This research project presents the idea of campus building energy optimization strategies according to the nature of building and occupants’ activities. World have been experiencing rapid growth for last few decades and thus cause the energy consumption rise drastically. Therefore, the objectives of this research are to propose the energy optimization approaches: set-point temperature and tinted window for campus building. The approaches were built according to the target building characteristic and focus and thermal consumption only. Energy consumption of the target building was simulated using energy simulation software (EnergyPlus) and the result was compared. The approaches proposed were verified using the software respectively. Simulation result shows that both approaches had successfully reduced the total building energy consumption by reducing HVAC system energy consumption. Set-point temperature reduced the annual energy consumption by 10.05% whereas tinted window would reduce the annual energy consumption by 3.25%. The results proved that the two optimization strategies could effectively reduce the cooling load and total energy consumption of the campus building.
format Thesis
author Chin, Yi Ming
author_facet Chin, Yi Ming
author_sort Chin, Yi Ming
title Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming
title_short Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming
title_full Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming
title_fullStr Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming
title_full_unstemmed Analysis of campus building energy optimization based on energy plus software simulation / Chi Yi Ming
title_sort analysis of campus building energy optimization based on energy plus software simulation / chi yi ming
publishDate 2018
url http://studentsrepo.um.edu.my/9558/1/Chin_Yi_Ming.jpg
http://studentsrepo.um.edu.my/9558/8/Research_Report_Final.pdf
http://studentsrepo.um.edu.my/9558/
_version_ 1738506277952159744