Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand

The unidirectional nature of centripetal flow, the predominant laminar flow in microfluidic systems, and the unreliability of the capillary valves are three main limitations exist in centrifugal microfluidics. This thesis presents the development of reversible microballoon pump, mixer and valve that...

Full description

Saved in:
Bibliographic Details
Main Author: Mohammad Mahdi, Aeinehvand
Format: Thesis
Published: 2016
Subjects:
Online Access:http://studentsrepo.um.edu.my/6645/4/mahdi.pdf
http://studentsrepo.um.edu.my/6645/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.stud.6645
record_format eprints
spelling my.um.stud.66452019-10-29T23:11:41Z Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand Mohammad Mahdi, Aeinehvand TP Chemical technology The unidirectional nature of centripetal flow, the predominant laminar flow in microfluidic systems, and the unreliability of the capillary valves are three main limitations exist in centrifugal microfluidics. This thesis presents the development of reversible microballoon pump, mixer and valve that enhance the control over the manipulation of liquids in bioanalytical assay on centrifugal microfluidic platforms. The high elasticity of the microballoon allows for an efficient conversion of centrifugally and externally induced forces to pumping, mixing and valving forces. The first liquid handling element presented in this thesis is a microballoon pump that relies on elastic energy stored in a latex membrane. It operates at low rotational speeds (< 1500 rpm) and pumps various liquid volumes towards the centre of the CD. The second presented liquid handling element is a microballoon mixer that operates by the expansion and relaxation of the membrane to provide for a consistent periodical 3D reciprocating flow. The third presented microballoon liquid handling element is a reversible thermo-pneumatic valve (RTPV) that seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. It employs the deflection of a latex membrane to control liquid flow and prevent evaporation of reagents over a wide range of spinning speeds (up to 6000 rpm) and temperatures (up to the operational temperature of the disk materials), respectively. To illustrate their practicality in real life applications, microballoon pump, mixer, and valves are used for the actuation of a siphon channel, biosensing enhancement of dengue virus, and controlling fluid flow in a continuous liquid circulation process, respectively. Finally, an array of RTPVs and a microballoon pump/mixer are imbedded in a microfluidic cartridge to automate a lab protocol required for the multiplexing of temperature-controlled assays. As a pilot study, the cartridge is used for the conversion of multiple dengue virus RNA to cDNA, and reused for the preparation of multiple separated PCR reaction mixtures. 2016 Thesis NonPeerReviewed application/pdf http://studentsrepo.um.edu.my/6645/4/mahdi.pdf Mohammad Mahdi, Aeinehvand (2016) Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand. PhD thesis, University of Malaya. http://studentsrepo.um.edu.my/6645/
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Student Repository
url_provider http://studentsrepo.um.edu.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Mohammad Mahdi, Aeinehvand
Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand
description The unidirectional nature of centripetal flow, the predominant laminar flow in microfluidic systems, and the unreliability of the capillary valves are three main limitations exist in centrifugal microfluidics. This thesis presents the development of reversible microballoon pump, mixer and valve that enhance the control over the manipulation of liquids in bioanalytical assay on centrifugal microfluidic platforms. The high elasticity of the microballoon allows for an efficient conversion of centrifugally and externally induced forces to pumping, mixing and valving forces. The first liquid handling element presented in this thesis is a microballoon pump that relies on elastic energy stored in a latex membrane. It operates at low rotational speeds (< 1500 rpm) and pumps various liquid volumes towards the centre of the CD. The second presented liquid handling element is a microballoon mixer that operates by the expansion and relaxation of the membrane to provide for a consistent periodical 3D reciprocating flow. The third presented microballoon liquid handling element is a reversible thermo-pneumatic valve (RTPV) that seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. It employs the deflection of a latex membrane to control liquid flow and prevent evaporation of reagents over a wide range of spinning speeds (up to 6000 rpm) and temperatures (up to the operational temperature of the disk materials), respectively. To illustrate their practicality in real life applications, microballoon pump, mixer, and valves are used for the actuation of a siphon channel, biosensing enhancement of dengue virus, and controlling fluid flow in a continuous liquid circulation process, respectively. Finally, an array of RTPVs and a microballoon pump/mixer are imbedded in a microfluidic cartridge to automate a lab protocol required for the multiplexing of temperature-controlled assays. As a pilot study, the cartridge is used for the conversion of multiple dengue virus RNA to cDNA, and reused for the preparation of multiple separated PCR reaction mixtures.
format Thesis
author Mohammad Mahdi, Aeinehvand
author_facet Mohammad Mahdi, Aeinehvand
author_sort Mohammad Mahdi, Aeinehvand
title Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand
title_short Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand
title_full Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand
title_fullStr Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand
title_full_unstemmed Reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / Mohammad Mahdi Aeinehvand
title_sort reversible microballoon system for handling bioanalytical assays on centrifugal microfluidic platform / mohammad mahdi aeinehvand
publishDate 2016
url http://studentsrepo.um.edu.my/6645/4/mahdi.pdf
http://studentsrepo.um.edu.my/6645/
_version_ 1738505940362067968
score 13.211869