Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study
The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, lef...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
British Institute of Radiology
2014
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/9877/1/Influence_of_object_location_in_different_FOVs_on_trabecular_bone_microstructure_measurements_of_human_mandible.pdf http://eprints.um.edu.my/9877/ http://www.birpublications.org/doi/abs/10.1259/dmfr.20130329 http://dx.doi.org/10.1259/dmfr.20130329 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.9877 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.98772018-10-09T08:25:48Z http://eprints.um.edu.my/9877/ Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study Ibrahim, Norliza Parsa, A. Hassan, B. van der Stelt, P. Aartman, I.H.A. Nambiar, Phrabhakaran RK Dentistry The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, left, right, anterior and posterior) using five different FOVs of two CBCT systems (NewTom™ 5G; QR Verona, Verona, Italy and Accuitomo 170; Morita, Kyoto, Japan). Image analysis software (CTAn software v. 1.1; SkyScan, Kontich, Belgium) was used to assess the trabecular bone microstructural parameters (thickness, Tb.Th; spacing, Tb.Sp; number, Tb.N; bone volume density, BV/TV). All measurements were taken twice by one trained observer. Tb.Th, Tb.Sp and Tb.N varied significantly across different FOVs in the NewTom 5G (p < 0.001) and the Accuitomo 170 (p < 0.001). For location, a significant difference was observed only when measuring BV/TV (p = 0.03) using the NewTom 5G. The trabecular bone microstructural measurements obtained from CBCT systems are influenced by the size of FOVs. Not all trabecular bone parameters measured using different CBCT systems are affected when varying the object location within the FOVs. British Institute of Radiology 2014-01-08 Article PeerReviewed application/pdf en http://eprints.um.edu.my/9877/1/Influence_of_object_location_in_different_FOVs_on_trabecular_bone_microstructure_measurements_of_human_mandible.pdf Ibrahim, Norliza and Parsa, A. and Hassan, B. and van der Stelt, P. and Aartman, I.H.A. and Nambiar, Phrabhakaran (2014) Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study. Dentomaxillofacial Radiology, 43 (2). p. 20130329. ISSN 1476-542X http://www.birpublications.org/doi/abs/10.1259/dmfr.20130329 http://dx.doi.org/10.1259/dmfr.20130329 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
language |
English |
topic |
RK Dentistry |
spellingShingle |
RK Dentistry Ibrahim, Norliza Parsa, A. Hassan, B. van der Stelt, P. Aartman, I.H.A. Nambiar, Phrabhakaran Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study |
description |
The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, left, right, anterior and posterior) using five different FOVs of two CBCT systems (NewTom™ 5G; QR Verona, Verona, Italy and Accuitomo 170; Morita, Kyoto, Japan). Image analysis software (CTAn software v. 1.1; SkyScan, Kontich, Belgium) was used to assess the trabecular bone microstructural parameters (thickness, Tb.Th; spacing, Tb.Sp; number, Tb.N; bone volume density, BV/TV). All measurements were taken twice by one trained observer. Tb.Th, Tb.Sp and Tb.N varied significantly across different FOVs in the NewTom 5G (p < 0.001) and the Accuitomo 170 (p < 0.001). For location, a significant difference was observed only when measuring BV/TV (p = 0.03) using the NewTom 5G. The trabecular bone microstructural measurements obtained from CBCT systems are influenced by the size of FOVs. Not all trabecular bone parameters measured using different CBCT systems are affected when varying the object location within the FOVs. |
format |
Article |
author |
Ibrahim, Norliza Parsa, A. Hassan, B. van der Stelt, P. Aartman, I.H.A. Nambiar, Phrabhakaran |
author_facet |
Ibrahim, Norliza Parsa, A. Hassan, B. van der Stelt, P. Aartman, I.H.A. Nambiar, Phrabhakaran |
author_sort |
Ibrahim, Norliza |
title |
Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study |
title_short |
Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study |
title_full |
Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study |
title_fullStr |
Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study |
title_full_unstemmed |
Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study |
title_sort |
influence of object location in different fovs on trabecular bone microstructure measurements of human mandible: a cone beam ct study |
publisher |
British Institute of Radiology |
publishDate |
2014 |
url |
http://eprints.um.edu.my/9877/1/Influence_of_object_location_in_different_FOVs_on_trabecular_bone_microstructure_measurements_of_human_mandible.pdf http://eprints.um.edu.my/9877/ http://www.birpublications.org/doi/abs/10.1259/dmfr.20130329 http://dx.doi.org/10.1259/dmfr.20130329 |
_version_ |
1643688675775610880 |
score |
13.211869 |