Optimum multi DG units placement and sizing based on voltage stability index and PSO

Optimum DG placement and sizing is one of the current topics in restructured power system. Most of the authors have worked out on their optimum placement base on the power losses reduction concept. However, the improvement on power losses value in the network will not guarantee to the planner to hav...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamian, J.J., Aman, M.M., Mustafa, M.W., Jasmon, G.B., Mokhlis, Hazlie, Bakar, A.H.A., Abdullah, M.N.
Format: Conference or Workshop Item
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.um.edu.my/7837/1/Optimum_multi_DG_units_placement_and_sizing_based_on_voltage_stability_index_and_PSO.pdf
http://eprints.um.edu.my/7837/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6398458
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.7837
record_format eprints
spelling my.um.eprints.78372019-10-09T08:56:47Z http://eprints.um.edu.my/7837/ Optimum multi DG units placement and sizing based on voltage stability index and PSO Jamian, J.J. Aman, M.M. Mustafa, M.W. Jasmon, G.B. Mokhlis, Hazlie Bakar, A.H.A. Abdullah, M.N. TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering Optimum DG placement and sizing is one of the current topics in restructured power system. Most of the authors have worked out on their optimum placement base on the power losses reduction concept. However, the improvement on power losses value in the network will not guarantee to the planner to have lower voltage stability index (VSI) for the system. This paper proposes a new approached for multi DG placement and sizing for distribution systems which is based on a voltage stability index. The most optimum DG size will be found out using several types of PSO optimization algorithm. The output results will also compared with EPSO, REPSO, and IPSO. The proposed algorithm is tested on 12-bus, modified 12-bus and 69-bus radial distribution networks. 2012 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.um.edu.my/7837/1/Optimum_multi_DG_units_placement_and_sizing_based_on_voltage_stability_index_and_PSO.pdf Jamian, J.J. and Aman, M.M. and Mustafa, M.W. and Jasmon, G.B. and Mokhlis, Hazlie and Bakar, A.H.A. and Abdullah, M.N. (2012) Optimum multi DG units placement and sizing based on voltage stability index and PSO. In: 2012 47th International Universities Power Engineering Conference, UPEC 2012, 2012, London. http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6398458
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
Jamian, J.J.
Aman, M.M.
Mustafa, M.W.
Jasmon, G.B.
Mokhlis, Hazlie
Bakar, A.H.A.
Abdullah, M.N.
Optimum multi DG units placement and sizing based on voltage stability index and PSO
description Optimum DG placement and sizing is one of the current topics in restructured power system. Most of the authors have worked out on their optimum placement base on the power losses reduction concept. However, the improvement on power losses value in the network will not guarantee to the planner to have lower voltage stability index (VSI) for the system. This paper proposes a new approached for multi DG placement and sizing for distribution systems which is based on a voltage stability index. The most optimum DG size will be found out using several types of PSO optimization algorithm. The output results will also compared with EPSO, REPSO, and IPSO. The proposed algorithm is tested on 12-bus, modified 12-bus and 69-bus radial distribution networks.
format Conference or Workshop Item
author Jamian, J.J.
Aman, M.M.
Mustafa, M.W.
Jasmon, G.B.
Mokhlis, Hazlie
Bakar, A.H.A.
Abdullah, M.N.
author_facet Jamian, J.J.
Aman, M.M.
Mustafa, M.W.
Jasmon, G.B.
Mokhlis, Hazlie
Bakar, A.H.A.
Abdullah, M.N.
author_sort Jamian, J.J.
title Optimum multi DG units placement and sizing based on voltage stability index and PSO
title_short Optimum multi DG units placement and sizing based on voltage stability index and PSO
title_full Optimum multi DG units placement and sizing based on voltage stability index and PSO
title_fullStr Optimum multi DG units placement and sizing based on voltage stability index and PSO
title_full_unstemmed Optimum multi DG units placement and sizing based on voltage stability index and PSO
title_sort optimum multi dg units placement and sizing based on voltage stability index and pso
publishDate 2012
url http://eprints.um.edu.my/7837/1/Optimum_multi_DG_units_placement_and_sizing_based_on_voltage_stability_index_and_PSO.pdf
http://eprints.um.edu.my/7837/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6398458
_version_ 1648736082916802560
score 13.211869