Study on corollary of seismic base isolation system on buildings with soft story

Soft storey buildings are characterized by having a storey which has a lot of open spaces. This soft storey creates a major weak point in an earthquake. Since soft stories are classically associated with retail spaces and parking garages, they are often on the lower stories of a building, which mean...

Full description

Saved in:
Bibliographic Details
Main Authors: Islam, A.B.M.S., Jameel, Mohammed, Ahmad, Syed Ishtiaq, Jumaat, Mohd Zamin
Format: Article
Published: Academic Journals 2011
Subjects:
Online Access:http://eprints.um.edu.my/7309/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.7309
record_format eprints
spelling my.um.eprints.73092020-02-05T04:31:10Z http://eprints.um.edu.my/7309/ Study on corollary of seismic base isolation system on buildings with soft story Islam, A.B.M.S. Jameel, Mohammed Ahmad, Syed Ishtiaq Jumaat, Mohd Zamin TA Engineering (General). Civil engineering (General) Soft storey buildings are characterized by having a storey which has a lot of open spaces. This soft storey creates a major weak point in an earthquake. Since soft stories are classically associated with retail spaces and parking garages, they are often on the lower stories of a building, which means that when they collapse, they can take the whole building down with them, causing serious structural damage which may render the structure totally unusable. In this study, efforts have been given to examine the effect of incorporation of isolator on the seismic behavior of buildings subjected to the appropriate earthquake for medium risk seismicity region. It duly ensures incorporating isolator with all relevant properties as per respective isolators along with its time period and damping ratio. Effort has also been made here to build up a relationship for increasing storey height and the changes for incorporating isolator with same time period and damping ratio for both lead rubber bearing (LRB) and high damping rubber bearing (HDRB). Dynamic analyses have been carried out using response spectrum and time history analysis. Behavioral changes of structural parameters are investigated. The study reveals that the values of structural parameters reduce a large amount while using isolator. However, LRB is found beneficial than HDRB. The structure experiences huge storey drift at the soft storey level that may be severe and cause immature failure. The amount of ma Academic Journals 2011 Article PeerReviewed Islam, A.B.M.S. and Jameel, Mohammed and Ahmad, Syed Ishtiaq and Jumaat, Mohd Zamin (2011) Study on corollary of seismic base isolation system on buildings with soft story. International Journal of the Physical Sciences, 6 (11). pp. 2654-2661. ISSN 1992-1950
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Islam, A.B.M.S.
Jameel, Mohammed
Ahmad, Syed Ishtiaq
Jumaat, Mohd Zamin
Study on corollary of seismic base isolation system on buildings with soft story
description Soft storey buildings are characterized by having a storey which has a lot of open spaces. This soft storey creates a major weak point in an earthquake. Since soft stories are classically associated with retail spaces and parking garages, they are often on the lower stories of a building, which means that when they collapse, they can take the whole building down with them, causing serious structural damage which may render the structure totally unusable. In this study, efforts have been given to examine the effect of incorporation of isolator on the seismic behavior of buildings subjected to the appropriate earthquake for medium risk seismicity region. It duly ensures incorporating isolator with all relevant properties as per respective isolators along with its time period and damping ratio. Effort has also been made here to build up a relationship for increasing storey height and the changes for incorporating isolator with same time period and damping ratio for both lead rubber bearing (LRB) and high damping rubber bearing (HDRB). Dynamic analyses have been carried out using response spectrum and time history analysis. Behavioral changes of structural parameters are investigated. The study reveals that the values of structural parameters reduce a large amount while using isolator. However, LRB is found beneficial than HDRB. The structure experiences huge storey drift at the soft storey level that may be severe and cause immature failure. The amount of ma
format Article
author Islam, A.B.M.S.
Jameel, Mohammed
Ahmad, Syed Ishtiaq
Jumaat, Mohd Zamin
author_facet Islam, A.B.M.S.
Jameel, Mohammed
Ahmad, Syed Ishtiaq
Jumaat, Mohd Zamin
author_sort Islam, A.B.M.S.
title Study on corollary of seismic base isolation system on buildings with soft story
title_short Study on corollary of seismic base isolation system on buildings with soft story
title_full Study on corollary of seismic base isolation system on buildings with soft story
title_fullStr Study on corollary of seismic base isolation system on buildings with soft story
title_full_unstemmed Study on corollary of seismic base isolation system on buildings with soft story
title_sort study on corollary of seismic base isolation system on buildings with soft story
publisher Academic Journals