Three phase grid connected anti-islanding controller based on distributed generation interconnection
This paper proposes three phase grid connected anti-islanding controller based on distributed generation interconnection. This method is a combination of two detection methods namely active and passive. Firstly, Active islanding detection generates disturbances at the output of the distributed gener...
محفوظ في:
المؤلفون الرئيسيون: | , |
---|---|
التنسيق: | Conference or Workshop Item |
اللغة: | English |
منشور في: |
2010
|
الموضوعات: | |
الوصول للمادة أونلاين: | http://eprints.um.edu.my/4833/1/Three_phase_grid_connected_anti-islanding_controller_based_on_distributed_generation_interconnection.pdf http://eprints.um.edu.my/4833/ http://www.scopus.com/inward/record.url?eid=2-s2.0-79951778205&partnerID=40&md5=c2bc5dc233d6040140aedce0a1bb270c |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
id |
my.um.eprints.4833 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.48332019-10-25T03:53:39Z http://eprints.um.edu.my/4833/ Three phase grid connected anti-islanding controller based on distributed generation interconnection Abdolrasol, M.G.M. Mekhilef, Saad TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering This paper proposes three phase grid connected anti-islanding controller based on distributed generation interconnection. This method is a combination of two detection methods namely active and passive. Firstly, Active islanding detection generates disturbances at the output of the distributed generation by use of Positive feedback and Continuous feedback signal injection which is based on DQ implementation. Secondly, passive islanding detection method is based on measuring the system parameters such as voltage, frequency, active and reactive power and total harmonic distortion (THD). This method use three phase RLC load and compares the performance of the technique with and without the anti islanding controller. Islanding conditions are simulated and verified with full analysis simulation and experimental result. 2010 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.um.edu.my/4833/1/Three_phase_grid_connected_anti-islanding_controller_based_on_distributed_generation_interconnection.pdf Abdolrasol, M.G.M. and Mekhilef, Saad (2010) Three phase grid connected anti-islanding controller based on distributed generation interconnection. In: 2010 IEEE International Conference on Power and Energy, PECon2010, Kuala Lumpur. http://www.scopus.com/inward/record.url?eid=2-s2.0-79951778205&partnerID=40&md5=c2bc5dc233d6040140aedce0a1bb270c |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering Abdolrasol, M.G.M. Mekhilef, Saad Three phase grid connected anti-islanding controller based on distributed generation interconnection |
description |
This paper proposes three phase grid connected anti-islanding controller based on distributed generation interconnection. This method is a combination of two detection methods namely active and passive. Firstly, Active islanding detection generates disturbances at the output of the distributed generation by use of Positive feedback and Continuous feedback signal injection which is based on DQ implementation. Secondly, passive islanding detection method is based on measuring the system parameters such as voltage, frequency, active and reactive power and total harmonic distortion (THD). This method use three phase RLC load and compares the performance of the technique with and without the anti islanding controller. Islanding conditions are simulated and verified with full analysis simulation and experimental result. |
format |
Conference or Workshop Item |
author |
Abdolrasol, M.G.M. Mekhilef, Saad |
author_facet |
Abdolrasol, M.G.M. Mekhilef, Saad |
author_sort |
Abdolrasol, M.G.M. |
title |
Three phase grid connected anti-islanding controller based on distributed generation interconnection |
title_short |
Three phase grid connected anti-islanding controller based on distributed generation interconnection |
title_full |
Three phase grid connected anti-islanding controller based on distributed generation interconnection |
title_fullStr |
Three phase grid connected anti-islanding controller based on distributed generation interconnection |
title_full_unstemmed |
Three phase grid connected anti-islanding controller based on distributed generation interconnection |
title_sort |
three phase grid connected anti-islanding controller based on distributed generation interconnection |
publishDate |
2010 |
url |
http://eprints.um.edu.my/4833/1/Three_phase_grid_connected_anti-islanding_controller_based_on_distributed_generation_interconnection.pdf http://eprints.um.edu.my/4833/ http://www.scopus.com/inward/record.url?eid=2-s2.0-79951778205&partnerID=40&md5=c2bc5dc233d6040140aedce0a1bb270c |
_version_ |
1648736012104368128 |
score |
13.251813 |