Clinical usefulness of abbreviated MRI protocol in breast cancer detection
Background: The use of breast MRI for screening has increased over the past decade, mostly in women with a high risk of breast cancer. Abbreviated breast MRI (AB-MR) is introduced to make MRI a more accessible screening modality. AB-MR decreases scanning and reporting time and the overall cost of MR...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Published: |
Bentham Science Publishers
2024
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/44999/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.44999 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.449992024-04-15T08:26:30Z http://eprints.um.edu.my/44999/ Clinical usefulness of abbreviated MRI protocol in breast cancer detection Hamid, Marlina Tanty Ramli Loi, Kai Seng Chan, Wai Yee Mumin, Nazimah Ab Hamid, Shamsiah Abdul Rozalli, Faizatul Izza Rahmat, Kartini R Medicine Background: The use of breast MRI for screening has increased over the past decade, mostly in women with a high risk of breast cancer. Abbreviated breast MRI (AB-MR) is introduced to make MRI a more accessible screening modality. AB-MR decreases scanning and reporting time and the overall cost of MRI. Objective: This study aims to evaluate the diagnostic efficacy of abbreviated MRI protocol in detecting breast cancer in screening and diagnostic populations, using histopathology as the reference standard. Materials and Methods: This is a single-centre retrospective cross-sectional study of 134 patients with 198 histologically proven breast lesions who underwent full diagnostic protocol contrast-enhanced breast MRI (FDP-MR) at the University Malaya Medical Centre (UMMC) from 1st January 2018 to 31st December 2019. AB-MR was pre-determined and evaluated with regard to the potential to detect and exclude malignancy from 3 readers of varying radiological experiences. The sensitivity of both AB-MR and FDP-MR were compared using the McNemar test, where both protocols' diagnostic performances were assessed via the receiver operating characteristic (ROC) curve. Inter-observer agreement was analysed using Fleiss Kappa. Results: There were 134 patients with 198 lesions. The average age was 50.9 years old (range 27 – 80). A total of 121 (90) MRIs were performed for diagnostic purposes. Screening accounted for 9.4 of the cases, 55.6 (n=110) lesions were benign, and 44.4 (n=88) were malignant. The commonest benign and malignant lesions were fibrocystic change (27.3) and invasive ductal carcinoma (78.4). The mean sensitivity, specificity, positive predictive value, and negative predictive value for AB-MR were 0.96, 0.57, 0.68 and 0.94, respectively. Both AB-MR and FDP-MR showed excellent diagnostic performance with AUC of 0.88 and 0.96, respectively. The general inter-observer agreement of all three readers for AB-MR was substantial (k=0.69), with fair agreement demonstrated between AB-MR and FDP-MR (k=0.36). Conclusion: The study shows no evidence that the diagnostic efficacy of AB-MR is inferior to FDP-MR. AB-MR, with high sensitivity, has proven its capability in cancer detection and exclusion, especially for biologically aggressive cancers. © 2024 The Author(s). Published by Bentham Science Publisher. Bentham Science Publishers 2024 Article PeerReviewed Hamid, Marlina Tanty Ramli and Loi, Kai Seng and Chan, Wai Yee and Mumin, Nazimah Ab and Hamid, Shamsiah Abdul and Rozalli, Faizatul Izza and Rahmat, Kartini (2024) Clinical usefulness of abbreviated MRI protocol in breast cancer detection. Current Medical Imaging, 20. ISSN 1573-4056, DOI https://doi.org/10.2174/1573405620666230829150218 <https://doi.org/10.2174/1573405620666230829150218>. 10.2174/1573405620666230829150218 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
R Medicine |
spellingShingle |
R Medicine Hamid, Marlina Tanty Ramli Loi, Kai Seng Chan, Wai Yee Mumin, Nazimah Ab Hamid, Shamsiah Abdul Rozalli, Faizatul Izza Rahmat, Kartini Clinical usefulness of abbreviated MRI protocol in breast cancer detection |
description |
Background: The use of breast MRI for screening has increased over the past decade, mostly in women with a high risk of breast cancer. Abbreviated breast MRI (AB-MR) is introduced to make MRI a more accessible screening modality. AB-MR decreases scanning and reporting time and the overall cost of MRI. Objective: This study aims to evaluate the diagnostic efficacy of abbreviated MRI protocol in detecting breast cancer in screening and diagnostic populations, using histopathology as the reference standard. Materials and Methods: This is a single-centre retrospective cross-sectional study of 134 patients with 198 histologically proven breast lesions who underwent full diagnostic protocol contrast-enhanced breast MRI (FDP-MR) at the University Malaya Medical Centre (UMMC) from 1st January 2018 to 31st December 2019. AB-MR was pre-determined and evaluated with regard to the potential to detect and exclude malignancy from 3 readers of varying radiological experiences. The sensitivity of both AB-MR and FDP-MR were compared using the McNemar test, where both protocols' diagnostic performances were assessed via the receiver operating characteristic (ROC) curve. Inter-observer agreement was analysed using Fleiss Kappa. Results: There were 134 patients with 198 lesions. The average age was 50.9 years old (range 27 – 80). A total of 121 (90) MRIs were performed for diagnostic purposes. Screening accounted for 9.4 of the cases, 55.6 (n=110) lesions were benign, and 44.4 (n=88) were malignant. The commonest benign and malignant lesions were fibrocystic change (27.3) and invasive ductal carcinoma (78.4). The mean sensitivity, specificity, positive predictive value, and negative predictive value for AB-MR were 0.96, 0.57, 0.68 and 0.94, respectively. Both AB-MR and FDP-MR showed excellent diagnostic performance with AUC of 0.88 and 0.96, respectively. The general inter-observer agreement of all three readers for AB-MR was substantial (k=0.69), with fair agreement demonstrated between AB-MR and FDP-MR (k=0.36). Conclusion: The study shows no evidence that the diagnostic efficacy of AB-MR is inferior to FDP-MR. AB-MR, with high sensitivity, has proven its capability in cancer detection and exclusion, especially for biologically aggressive cancers. © 2024 The Author(s). Published by Bentham Science Publisher. |
format |
Article |
author |
Hamid, Marlina Tanty Ramli Loi, Kai Seng Chan, Wai Yee Mumin, Nazimah Ab Hamid, Shamsiah Abdul Rozalli, Faizatul Izza Rahmat, Kartini |
author_facet |
Hamid, Marlina Tanty Ramli Loi, Kai Seng Chan, Wai Yee Mumin, Nazimah Ab Hamid, Shamsiah Abdul Rozalli, Faizatul Izza Rahmat, Kartini |
author_sort |
Hamid, Marlina Tanty Ramli |
title |
Clinical usefulness of abbreviated MRI protocol in breast cancer detection |
title_short |
Clinical usefulness of abbreviated MRI protocol in breast cancer detection |
title_full |
Clinical usefulness of abbreviated MRI protocol in breast cancer detection |
title_fullStr |
Clinical usefulness of abbreviated MRI protocol in breast cancer detection |
title_full_unstemmed |
Clinical usefulness of abbreviated MRI protocol in breast cancer detection |
title_sort |
clinical usefulness of abbreviated mri protocol in breast cancer detection |
publisher |
Bentham Science Publishers |
publishDate |
2024 |
url |
http://eprints.um.edu.my/44999/ |
_version_ |
1797906867372949504 |
score |
13.211869 |