Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report

Background: Human walking has been extensively studied but less research has been done on the gait of trilateral amputee. Trilateral amputee is a person with three missing limbs. This study investigates the effect of upper limb prostheses on vertical ground reaction force of a trilateral amputee dur...

Full description

Saved in:
Bibliographic Details
Main Authors: Hashim, Nur Afiqah, Abd Razak, Nasrul Anuar, Abu Osman, Noor Azuan
Format: Conference or Workshop Item
Published: Springer Science and Business Media Deutschland GmbH 2022
Subjects:
Online Access:http://eprints.um.edu.my/43470/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85129273825&doi=10.1007%2f978-3-030-90724-2_20&partnerID=40&md5=bc05dccdf212a39d5779695a37f66f95
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.43470
record_format eprints
spelling my.um.eprints.434702025-02-10T08:00:32Z http://eprints.um.edu.my/43470/ Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report Hashim, Nur Afiqah Abd Razak, Nasrul Anuar Abu Osman, Noor Azuan R Medicine TA Engineering (General). Civil engineering (General) Background: Human walking has been extensively studied but less research has been done on the gait of trilateral amputee. Trilateral amputee is a person with three missing limbs. This study investigates the effect of upper limb prostheses on vertical ground reaction force of a trilateral amputee during level walking. A subject with bilateral transradial and unilateral transtibial amputation participated in this study. The subject wore prostheses both for upper and lower limb. Kristler force platform was used to collect data while the subject walked with and without upper limb prosthesis. The determined mean values of normalized components of trajectory of vertical ground reaction force were compared with able-bodied data. Three vertical GRF measures (F1, the first peak force; F2, minimum force; and F3, the second peak force) were extracted and analyzed. Ground reaction force, loading rate and unloading rate generated by the trilateral amputee is greater than able-bodied person. When donning upper limb prosthesis, the value of F1 and F3 increased by 11.93 and 9.90 respectively, but the value of F2 reduced by 8.75. The gait of trilateral amputee wearing upper limb prosthesis were characterized by high impact peak, low force value during mid stance and steeper loading rate and unloading rate. The use of upper limb prostheses affects the vertical ground reaction force of trilateral amputee subject in this study during walking. © 2022, Springer Nature Switzerland AG. Springer Science and Business Media Deutschland GmbH 2022 Conference or Workshop Item PeerReviewed Hashim, Nur Afiqah and Abd Razak, Nasrul Anuar and Abu Osman, Noor Azuan (2022) Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report. In: 6th Kuala Lumpur International Conference on Biomedical Engineering, BioMed 2021, 28-29 July 2021, Virtual, Online. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85129273825&doi=10.1007%2f978-3-030-90724-2_20&partnerID=40&md5=bc05dccdf212a39d5779695a37f66f95
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine
TA Engineering (General). Civil engineering (General)
spellingShingle R Medicine
TA Engineering (General). Civil engineering (General)
Hashim, Nur Afiqah
Abd Razak, Nasrul Anuar
Abu Osman, Noor Azuan
Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report
description Background: Human walking has been extensively studied but less research has been done on the gait of trilateral amputee. Trilateral amputee is a person with three missing limbs. This study investigates the effect of upper limb prostheses on vertical ground reaction force of a trilateral amputee during level walking. A subject with bilateral transradial and unilateral transtibial amputation participated in this study. The subject wore prostheses both for upper and lower limb. Kristler force platform was used to collect data while the subject walked with and without upper limb prosthesis. The determined mean values of normalized components of trajectory of vertical ground reaction force were compared with able-bodied data. Three vertical GRF measures (F1, the first peak force; F2, minimum force; and F3, the second peak force) were extracted and analyzed. Ground reaction force, loading rate and unloading rate generated by the trilateral amputee is greater than able-bodied person. When donning upper limb prosthesis, the value of F1 and F3 increased by 11.93 and 9.90 respectively, but the value of F2 reduced by 8.75. The gait of trilateral amputee wearing upper limb prosthesis were characterized by high impact peak, low force value during mid stance and steeper loading rate and unloading rate. The use of upper limb prostheses affects the vertical ground reaction force of trilateral amputee subject in this study during walking. © 2022, Springer Nature Switzerland AG.
format Conference or Workshop Item
author Hashim, Nur Afiqah
Abd Razak, Nasrul Anuar
Abu Osman, Noor Azuan
author_facet Hashim, Nur Afiqah
Abd Razak, Nasrul Anuar
Abu Osman, Noor Azuan
author_sort Hashim, Nur Afiqah
title Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report
title_short Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report
title_full Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report
title_fullStr Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report
title_full_unstemmed Ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report
title_sort ground reaction force of trilateral amputee during walking with and without upper limb prosthesis: case report
publisher Springer Science and Business Media Deutschland GmbH
publishDate 2022
url http://eprints.um.edu.my/43470/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85129273825&doi=10.1007%2f978-3-030-90724-2_20&partnerID=40&md5=bc05dccdf212a39d5779695a37f66f95
_version_ 1825160594804703232
score 13.239859