Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface

Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI; however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based...

Full description

Saved in:
Bibliographic Details
Main Authors: Hui, Hu, Gopinath, Subash C. B., Ismail, Zool H., Chen, Yeng, Pandian, K., Velusamy, Palaniyandi
Format: Article
Published: Wiley 2023
Subjects:
Online Access:http://eprints.um.edu.my/39507/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.39507
record_format eprints
spelling my.um.eprints.395072023-07-13T03:21:49Z http://eprints.um.edu.my/39507/ Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface Hui, Hu Gopinath, Subash C. B. Ismail, Zool H. Chen, Yeng Pandian, K. Velusamy, Palaniyandi Q Science (General) QD Chemistry QH301 Biology Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI; however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based diagnosis is an immediate solution, and due to the high correlation of troponin with MI, it has been considered to be a gold-standard biomarker. In the present research, the cardiac biomarker troponin I (cTnI) was detected on an interdigitated electrode sensor with various surface interfaces. To detect cTnI, a capture aptamer-conjugated gold nanoparticle probe and detection antibody probe were utilized and compared through an alternating sandwich pattern. The surface metal oxide morphology of the developed sensor was proven by microscopic assessments. The limit of detection with the aptamer-gold-cTnI-antibody sandwich pattern was 100 aM, while it was 1 fM with antibody-gold-cTnI-aptamer, representing 10-fold differences. Further, the high performance of the sensor was confirmed by selective cTnI determination in serum, exhibiting superior nonfouling. These methods of determination provide options for generating novel assays for diagnosing MI. Wiley 2023-04 Article PeerReviewed Hui, Hu and Gopinath, Subash C. B. and Ismail, Zool H. and Chen, Yeng and Pandian, K. and Velusamy, Palaniyandi (2023) Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface. Biotechnology and Applied Biochemistry, 70 (2). pp. 581-591. ISSN 0885-4513, DOI https://doi.org/10.1002/bab.2380 <https://doi.org/10.1002/bab.2380>. 10.1002/bab.2380
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
QD Chemistry
QH301 Biology
spellingShingle Q Science (General)
QD Chemistry
QH301 Biology
Hui, Hu
Gopinath, Subash C. B.
Ismail, Zool H.
Chen, Yeng
Pandian, K.
Velusamy, Palaniyandi
Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
description Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI; however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based diagnosis is an immediate solution, and due to the high correlation of troponin with MI, it has been considered to be a gold-standard biomarker. In the present research, the cardiac biomarker troponin I (cTnI) was detected on an interdigitated electrode sensor with various surface interfaces. To detect cTnI, a capture aptamer-conjugated gold nanoparticle probe and detection antibody probe were utilized and compared through an alternating sandwich pattern. The surface metal oxide morphology of the developed sensor was proven by microscopic assessments. The limit of detection with the aptamer-gold-cTnI-antibody sandwich pattern was 100 aM, while it was 1 fM with antibody-gold-cTnI-aptamer, representing 10-fold differences. Further, the high performance of the sensor was confirmed by selective cTnI determination in serum, exhibiting superior nonfouling. These methods of determination provide options for generating novel assays for diagnosing MI.
format Article
author Hui, Hu
Gopinath, Subash C. B.
Ismail, Zool H.
Chen, Yeng
Pandian, K.
Velusamy, Palaniyandi
author_facet Hui, Hu
Gopinath, Subash C. B.
Ismail, Zool H.
Chen, Yeng
Pandian, K.
Velusamy, Palaniyandi
author_sort Hui, Hu
title Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_short Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_full Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_fullStr Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_full_unstemmed Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_sort cardiovascular biomarker troponin i biosensor: aptamer-gold-antibody hybrid on a metal oxide surface
publisher Wiley
publishDate 2023
url http://eprints.um.edu.my/39507/
_version_ 1772811759361458176
score 13.211869