Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors

This article compares the performances of uncoated and coated optical microbottle resonators (MBR) for humidity sensing. A technique called ``soften-and-compress'' was used to form the MBR with midriff diameter of D-b = 190 mu m, stem diameter of D-s = 125 mu m and bottle length of L-b = 1...

Full description

Saved in:
Bibliographic Details
Main Authors: Johari, Md Ashadi Md, Pour, Meisam Parsa, Al Noman, Abdullah, Khudus, Muhammad Imran Mustafa Abdul, Bin Jali, Mohd Hafiz, Maslinda, M. S., Ali, Ummu Umairah Mohd, Harun, Sulaiman Wadi
Format: Article
Published: John Wiley & Sons 2020
Subjects:
Online Access:http://eprints.um.edu.my/37244/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.37244
record_format eprints
spelling my.um.eprints.372442023-03-09T02:20:51Z http://eprints.um.edu.my/37244/ Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors Johari, Md Ashadi Md Pour, Meisam Parsa Al Noman, Abdullah Khudus, Muhammad Imran Mustafa Abdul Bin Jali, Mohd Hafiz Maslinda, M. S. Ali, Ummu Umairah Mohd Harun, Sulaiman Wadi QC Physics TK Electrical engineering. Electronics Nuclear engineering This article compares the performances of uncoated and coated optical microbottle resonators (MBR) for humidity sensing. A technique called ``soften-and-compress'' was used to form the MBR with midriff diameter of D-b = 190 mu m, stem diameter of D-s = 125 mu m and bottle length of L-b = 182 mu m. The MBRs were prepared in three different conditions, which are noncoated MBR, PMMA (poly methyl meth acrylate) coated MBR, and PVA (polyvinyl-alcohol) coated MBR. The MBRs characteristic was investigated by employing a 2 mu m tapered microfiber and tested for humidity sensing within a humidity range of 40% to 95%. The Q-factor obtained were >10(4) for all MBRs. The performance as humidity sensor was defined by the sensitivity and linearity of MBRs, which were investigated based on wavelength shift and also the transmitted power. The MBRs are undergoing a 180-seconds stability test at 65% RH humidity level. It is found that the PVA coated MBR performed better than other MBRs as a humidity sensor based on sensitivity, linearity, and stability measurements. John Wiley & Sons 2020-03 Article PeerReviewed Johari, Md Ashadi Md and Pour, Meisam Parsa and Al Noman, Abdullah and Khudus, Muhammad Imran Mustafa Abdul and Bin Jali, Mohd Hafiz and Maslinda, M. S. and Ali, Ummu Umairah Mohd and Harun, Sulaiman Wadi (2020) Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors. Microwave and Optical Technology Letters, 62 (3). pp. 993-998. ISSN 0895-2477, DOI https://doi.org/10.1002/mop.32133 <https://doi.org/10.1002/mop.32133>. 10.1002/mop.32133
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QC Physics
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle QC Physics
TK Electrical engineering. Electronics Nuclear engineering
Johari, Md Ashadi Md
Pour, Meisam Parsa
Al Noman, Abdullah
Khudus, Muhammad Imran Mustafa Abdul
Bin Jali, Mohd Hafiz
Maslinda, M. S.
Ali, Ummu Umairah Mohd
Harun, Sulaiman Wadi
Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors
description This article compares the performances of uncoated and coated optical microbottle resonators (MBR) for humidity sensing. A technique called ``soften-and-compress'' was used to form the MBR with midriff diameter of D-b = 190 mu m, stem diameter of D-s = 125 mu m and bottle length of L-b = 182 mu m. The MBRs were prepared in three different conditions, which are noncoated MBR, PMMA (poly methyl meth acrylate) coated MBR, and PVA (polyvinyl-alcohol) coated MBR. The MBRs characteristic was investigated by employing a 2 mu m tapered microfiber and tested for humidity sensing within a humidity range of 40% to 95%. The Q-factor obtained were >10(4) for all MBRs. The performance as humidity sensor was defined by the sensitivity and linearity of MBRs, which were investigated based on wavelength shift and also the transmitted power. The MBRs are undergoing a 180-seconds stability test at 65% RH humidity level. It is found that the PVA coated MBR performed better than other MBRs as a humidity sensor based on sensitivity, linearity, and stability measurements.
format Article
author Johari, Md Ashadi Md
Pour, Meisam Parsa
Al Noman, Abdullah
Khudus, Muhammad Imran Mustafa Abdul
Bin Jali, Mohd Hafiz
Maslinda, M. S.
Ali, Ummu Umairah Mohd
Harun, Sulaiman Wadi
author_facet Johari, Md Ashadi Md
Pour, Meisam Parsa
Al Noman, Abdullah
Khudus, Muhammad Imran Mustafa Abdul
Bin Jali, Mohd Hafiz
Maslinda, M. S.
Ali, Ummu Umairah Mohd
Harun, Sulaiman Wadi
author_sort Johari, Md Ashadi Md
title Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors
title_short Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors
title_full Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors
title_fullStr Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors
title_full_unstemmed Effect of PMMA and PVA coating on the performance of optical microbottle resonator humidity sensors
title_sort effect of pmma and pva coating on the performance of optical microbottle resonator humidity sensors
publisher John Wiley & Sons
publishDate 2020
url http://eprints.um.edu.my/37244/
_version_ 1761616813847740416
score 13.211869