Two-terminal fault detection and location for hybrid transmission circuit
This paper presents the algorithms developed to detect and locate the faults at a hybrid circuit. First, the fault detection algorithm was developed using the comparison of total positive-sequence fault current between pre-fault and fault times to detect the occurrence of a fault. Then, the voltage...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Institute of Advanced Engineering and Science
2021
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/35947/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85112156731&doi=10.11591%2fijeecs.v23.i2.pp639-649&partnerID=40&md5=a6c12742a861f58af1e1207ba4de7415 http://doi.org/10.11591/ijeecs.v23.i2.pp639-649 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.35947 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.359472022-11-01T07:29:49Z http://eprints.um.edu.my/35947/ Two-terminal fault detection and location for hybrid transmission circuit Idris, Muhd Hafizi Adzman, Mohd Rafi Mokhlis, Hazlie Tajuddin, Mohammad Faridun Naim Hamid, Haziah Amirruddin, Melaty TK Electrical engineering. Electronics Nuclear engineering This paper presents the algorithms developed to detect and locate the faults at a hybrid circuit. First, the fault detection algorithm was developed using the comparison of total positive-sequence fault current between pre-fault and fault times to detect the occurrence of a fault. Then, the voltage check method was used to decide whether the fault occurred at overhead line (OHL) or cable section. Finally, the fault location algorithm using the impedance-based method and negative-sequence measurements from both terminals of the circuit were used to estimate the fault point from local terminal. From the tests of various fault conditions including different fault types, fault resistance and fault locations, the proposed method successfully detected all fault cases at around 1 cycle from fault initiation and with correct faulted section identification. Besides that, the fault location algorithm also has very accurate results of fault estimation with average error less than 1 km and 1. © 2021 Institute of Advanced Engineering and Science. All rights reserved. Institute of Advanced Engineering and Science 2021 Article PeerReviewed Idris, Muhd Hafizi and Adzman, Mohd Rafi and Mokhlis, Hazlie and Tajuddin, Mohammad Faridun Naim and Hamid, Haziah and Amirruddin, Melaty (2021) Two-terminal fault detection and location for hybrid transmission circuit. Indonesian Journal of Electrical Engineering and Computer Science, 23 (2). pp. 639-649. ISSN 2502-4752, DOI https://doi.org/10.11591/ijeecs.v23.i2.pp639-649 <https://doi.org/10.11591/ijeecs.v23.i2.pp639-649>. https://www.scopus.com/inward/record.uri?eid=2-s2.0-85112156731&doi=10.11591%2fijeecs.v23.i2.pp639-649&partnerID=40&md5=a6c12742a861f58af1e1207ba4de7415 http://doi.org/10.11591/ijeecs.v23.i2.pp639-649 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Idris, Muhd Hafizi Adzman, Mohd Rafi Mokhlis, Hazlie Tajuddin, Mohammad Faridun Naim Hamid, Haziah Amirruddin, Melaty Two-terminal fault detection and location for hybrid transmission circuit |
description |
This paper presents the algorithms developed to detect and locate the faults at a hybrid circuit. First, the fault detection algorithm was developed using the comparison of total positive-sequence fault current between pre-fault and fault times to detect the occurrence of a fault. Then, the voltage check method was used to decide whether the fault occurred at overhead line (OHL) or cable section. Finally, the fault location algorithm using the impedance-based method and negative-sequence measurements from both terminals of the circuit were used to estimate the fault point from local terminal. From the tests of various fault conditions including different fault types, fault resistance and fault locations, the proposed method successfully detected all fault cases at around 1 cycle from fault initiation and with correct faulted section identification. Besides that, the fault location algorithm also has very accurate results of fault estimation with average error less than 1 km and 1. © 2021 Institute of Advanced Engineering and Science. All rights reserved. |
format |
Article |
author |
Idris, Muhd Hafizi Adzman, Mohd Rafi Mokhlis, Hazlie Tajuddin, Mohammad Faridun Naim Hamid, Haziah Amirruddin, Melaty |
author_facet |
Idris, Muhd Hafizi Adzman, Mohd Rafi Mokhlis, Hazlie Tajuddin, Mohammad Faridun Naim Hamid, Haziah Amirruddin, Melaty |
author_sort |
Idris, Muhd Hafizi |
title |
Two-terminal fault detection and location for hybrid transmission circuit |
title_short |
Two-terminal fault detection and location for hybrid transmission circuit |
title_full |
Two-terminal fault detection and location for hybrid transmission circuit |
title_fullStr |
Two-terminal fault detection and location for hybrid transmission circuit |
title_full_unstemmed |
Two-terminal fault detection and location for hybrid transmission circuit |
title_sort |
two-terminal fault detection and location for hybrid transmission circuit |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2021 |
url |
http://eprints.um.edu.my/35947/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85112156731&doi=10.11591%2fijeecs.v23.i2.pp639-649&partnerID=40&md5=a6c12742a861f58af1e1207ba4de7415 http://doi.org/10.11591/ijeecs.v23.i2.pp639-649 |
_version_ |
1748703485624320000 |
score |
13.211869 |