Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction

A monolithic, fully coupled fluid-structure interaction (FSI) computational framework was developed to account for dissection flap motion in acute type B aortic dissection (TBAD). Analysis of results included wall deformation, pressure, flow, wall shear stress (WSS), von Mises stress and comparison...

Full description

Saved in:
Bibliographic Details
Main Authors: Chong, Mei Yan, Gu, Boram, Chan, Bee Ting, Ong, Zhi Chao, Xu, Xiao Yun, Lim, Einly
Format: Article
Published: Wiley 2020
Subjects:
Online Access:http://eprints.um.edu.my/31687/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.31687
record_format eprints
spelling my.um.eprints.316872022-09-19T02:40:29Z http://eprints.um.edu.my/31687/ Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction Chong, Mei Yan Gu, Boram Chan, Bee Ting Ong, Zhi Chao Xu, Xiao Yun Lim, Einly QA Mathematics TA Engineering (General). Civil engineering (General) A monolithic, fully coupled fluid-structure interaction (FSI) computational framework was developed to account for dissection flap motion in acute type B aortic dissection (TBAD). Analysis of results included wall deformation, pressure, flow, wall shear stress (WSS), von Mises stress and comparison of hemodynamics between rigid wall and FSI models. Our FSI model mimicked realistic wall deformation that resulted in maximum compression of the distal true lumen (TL) by 21.4%. The substantial movement of intimal flap mostly affected flow conditions in the false lumen (FL). Flap motion facilitated more flow entering the FL at peak systole, with the TL to FL flow split changing from 88:12 in the rigid model to 83:17 in the FSI model. There was more disturbed flow in the FL during systole (5.8% FSI vs 5.2% rigid) and diastole (13.5% FSI vs 9.8% rigid), via a lambda(2)-criterion. The flap-induced disturbed flow near the tears in the FSI model caused an increase of local WSS by up to 70.0% during diastole. This resulted in a significant reduction in the size of low time-averaged WSS (TAWSS) regions in the FL (113.11 cm(2)FSI vs 177.44 cm(2)rigid). Moreover, the FSI model predicted lower systolic pressure, higher diastolic pressure, and hence lower pulse pressure. Our results provided new insights into the possible impact of flap motion on flow in aortic dissections, which are particularly important when evaluating hemodynamics of acute TBAD. Novelty Statement Our monolithic fully coupled FSI computational framework is able to reproduce experimentally measured range of flap deformation in aortic dissection, thereby providing novel insights into the influence of physiological flap motion on the flow and pressure distributions. The drastic flap movement increases the flow resistance in the true lumen and causes more disturbed flow in the false lumen, as visualized through the lambda(2)criterion. The flap-induced luminal pressure is dampened, thereby affecting pressure measures, which may serve as potential prognostic indicators for late complications in acute uncomplicated TBAD patients. Wiley 2020-12 Article PeerReviewed Chong, Mei Yan and Gu, Boram and Chan, Bee Ting and Ong, Zhi Chao and Xu, Xiao Yun and Lim, Einly (2020) Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction. International Journal for Numerical Methods in Biomedical Engineering, 36 (12). ISSN 2040-7939, DOI https://doi.org/10.1002/cnm.3399 <https://doi.org/10.1002/cnm.3399>. 10.1002/cnm.3399
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QA Mathematics
TA Engineering (General). Civil engineering (General)
spellingShingle QA Mathematics
TA Engineering (General). Civil engineering (General)
Chong, Mei Yan
Gu, Boram
Chan, Bee Ting
Ong, Zhi Chao
Xu, Xiao Yun
Lim, Einly
Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction
description A monolithic, fully coupled fluid-structure interaction (FSI) computational framework was developed to account for dissection flap motion in acute type B aortic dissection (TBAD). Analysis of results included wall deformation, pressure, flow, wall shear stress (WSS), von Mises stress and comparison of hemodynamics between rigid wall and FSI models. Our FSI model mimicked realistic wall deformation that resulted in maximum compression of the distal true lumen (TL) by 21.4%. The substantial movement of intimal flap mostly affected flow conditions in the false lumen (FL). Flap motion facilitated more flow entering the FL at peak systole, with the TL to FL flow split changing from 88:12 in the rigid model to 83:17 in the FSI model. There was more disturbed flow in the FL during systole (5.8% FSI vs 5.2% rigid) and diastole (13.5% FSI vs 9.8% rigid), via a lambda(2)-criterion. The flap-induced disturbed flow near the tears in the FSI model caused an increase of local WSS by up to 70.0% during diastole. This resulted in a significant reduction in the size of low time-averaged WSS (TAWSS) regions in the FL (113.11 cm(2)FSI vs 177.44 cm(2)rigid). Moreover, the FSI model predicted lower systolic pressure, higher diastolic pressure, and hence lower pulse pressure. Our results provided new insights into the possible impact of flap motion on flow in aortic dissections, which are particularly important when evaluating hemodynamics of acute TBAD. Novelty Statement Our monolithic fully coupled FSI computational framework is able to reproduce experimentally measured range of flap deformation in aortic dissection, thereby providing novel insights into the influence of physiological flap motion on the flow and pressure distributions. The drastic flap movement increases the flow resistance in the true lumen and causes more disturbed flow in the false lumen, as visualized through the lambda(2)criterion. The flap-induced luminal pressure is dampened, thereby affecting pressure measures, which may serve as potential prognostic indicators for late complications in acute uncomplicated TBAD patients.
format Article
author Chong, Mei Yan
Gu, Boram
Chan, Bee Ting
Ong, Zhi Chao
Xu, Xiao Yun
Lim, Einly
author_facet Chong, Mei Yan
Gu, Boram
Chan, Bee Ting
Ong, Zhi Chao
Xu, Xiao Yun
Lim, Einly
author_sort Chong, Mei Yan
title Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction
title_short Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction
title_full Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction
title_fullStr Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction
title_full_unstemmed Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction
title_sort effect of intimal flap motion on flow in acute type b aortic dissection by using fluid-structure interaction
publisher Wiley
publishDate 2020
url http://eprints.um.edu.my/31687/
_version_ 1744649144165728256
score 13.211869