Design of graphene metasurface based sensitive infrared biosensor
The article investigates graphene metasurface based infrared biosensor. Graphene metasurface perturbations are added in the Si3N4 waveguide to create leaky wave structure. Biomolecules in blood plasma form are placed over the Si3N4 waveguide to observe the sensing characteristics. Numerical results...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Published: |
Elsevier
2020
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/25411/ https://doi.org/10.1016/j.sna.2019.111767 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.25411 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.254112020-08-19T00:37:36Z http://eprints.um.edu.my/25411/ Design of graphene metasurface based sensitive infrared biosensor Patel, Shobhit K. Parmar, Juveriya Kosta, Yogeshwar P. Ladumor, Mayurkumar Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran QC Physics TK Electrical engineering. Electronics Nuclear engineering The article investigates graphene metasurface based infrared biosensor. Graphene metasurface perturbations are added in the Si3N4 waveguide to create leaky wave structure. Biomolecules in blood plasma form are placed over the Si3N4 waveguide to observe the sensing characteristics. Numerical results of absorption, reflectance, electric field and sensitivity are presented in this paper. The sensitivity is calculated from the shift in the absorption peak of biosensor. The sensitivity of the proposed biosensor is also compared with the previously published biosensor designs. In addition, the design results in the form of absorption and reflectance is observed for the different physical parameters like waveguide height (S), biomolecules/air layer height(B), SiO2 layer height(C) and graphene perturbations period(G). The corresponding electric field response is also presented for the proposed design at different frequencies to show the leakage of light in the biomolecules layer. © 2019 Elsevier B.V. Elsevier 2020 Article PeerReviewed Patel, Shobhit K. and Parmar, Juveriya and Kosta, Yogeshwar P. and Ladumor, Mayurkumar and Zakaria, Rozalina and Nguyen, Truong Khang and Dhasarathan, Vigneswaran (2020) Design of graphene metasurface based sensitive infrared biosensor. Sensors and Actuators A: Physical, 301. p. 111767. ISSN 0924-4247 https://doi.org/10.1016/j.sna.2019.111767 doi:10.1016/j.sna.2019.111767 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
QC Physics TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
QC Physics TK Electrical engineering. Electronics Nuclear engineering Patel, Shobhit K. Parmar, Juveriya Kosta, Yogeshwar P. Ladumor, Mayurkumar Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran Design of graphene metasurface based sensitive infrared biosensor |
description |
The article investigates graphene metasurface based infrared biosensor. Graphene metasurface perturbations are added in the Si3N4 waveguide to create leaky wave structure. Biomolecules in blood plasma form are placed over the Si3N4 waveguide to observe the sensing characteristics. Numerical results of absorption, reflectance, electric field and sensitivity are presented in this paper. The sensitivity is calculated from the shift in the absorption peak of biosensor. The sensitivity of the proposed biosensor is also compared with the previously published biosensor designs. In addition, the design results in the form of absorption and reflectance is observed for the different physical parameters like waveguide height (S), biomolecules/air layer height(B), SiO2 layer height(C) and graphene perturbations period(G). The corresponding electric field response is also presented for the proposed design at different frequencies to show the leakage of light in the biomolecules layer. © 2019 Elsevier B.V. |
format |
Article |
author |
Patel, Shobhit K. Parmar, Juveriya Kosta, Yogeshwar P. Ladumor, Mayurkumar Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran |
author_facet |
Patel, Shobhit K. Parmar, Juveriya Kosta, Yogeshwar P. Ladumor, Mayurkumar Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran |
author_sort |
Patel, Shobhit K. |
title |
Design of graphene metasurface based sensitive infrared biosensor |
title_short |
Design of graphene metasurface based sensitive infrared biosensor |
title_full |
Design of graphene metasurface based sensitive infrared biosensor |
title_fullStr |
Design of graphene metasurface based sensitive infrared biosensor |
title_full_unstemmed |
Design of graphene metasurface based sensitive infrared biosensor |
title_sort |
design of graphene metasurface based sensitive infrared biosensor |
publisher |
Elsevier |
publishDate |
2020 |
url |
http://eprints.um.edu.my/25411/ https://doi.org/10.1016/j.sna.2019.111767 |
_version_ |
1680857029791449088 |
score |
13.211869 |