Design of graphene metasurface based sensitive infrared biosensor

The article investigates graphene metasurface based infrared biosensor. Graphene metasurface perturbations are added in the Si3N4 waveguide to create leaky wave structure. Biomolecules in blood plasma form are placed over the Si3N4 waveguide to observe the sensing characteristics. Numerical results...

Full description

Saved in:
Bibliographic Details
Main Authors: Patel, Shobhit K., Parmar, Juveriya, Kosta, Yogeshwar P., Ladumor, Mayurkumar, Zakaria, Rozalina, Nguyen, Truong Khang, Dhasarathan, Vigneswaran
Format: Article
Published: Elsevier 2020
Subjects:
Online Access:http://eprints.um.edu.my/25411/
https://doi.org/10.1016/j.sna.2019.111767
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.25411
record_format eprints
spelling my.um.eprints.254112020-08-19T00:37:36Z http://eprints.um.edu.my/25411/ Design of graphene metasurface based sensitive infrared biosensor Patel, Shobhit K. Parmar, Juveriya Kosta, Yogeshwar P. Ladumor, Mayurkumar Zakaria, Rozalina Nguyen, Truong Khang Dhasarathan, Vigneswaran QC Physics TK Electrical engineering. Electronics Nuclear engineering The article investigates graphene metasurface based infrared biosensor. Graphene metasurface perturbations are added in the Si3N4 waveguide to create leaky wave structure. Biomolecules in blood plasma form are placed over the Si3N4 waveguide to observe the sensing characteristics. Numerical results of absorption, reflectance, electric field and sensitivity are presented in this paper. The sensitivity is calculated from the shift in the absorption peak of biosensor. The sensitivity of the proposed biosensor is also compared with the previously published biosensor designs. In addition, the design results in the form of absorption and reflectance is observed for the different physical parameters like waveguide height (S), biomolecules/air layer height(B), SiO2 layer height(C) and graphene perturbations period(G). The corresponding electric field response is also presented for the proposed design at different frequencies to show the leakage of light in the biomolecules layer. © 2019 Elsevier B.V. Elsevier 2020 Article PeerReviewed Patel, Shobhit K. and Parmar, Juveriya and Kosta, Yogeshwar P. and Ladumor, Mayurkumar and Zakaria, Rozalina and Nguyen, Truong Khang and Dhasarathan, Vigneswaran (2020) Design of graphene metasurface based sensitive infrared biosensor. Sensors and Actuators A: Physical, 301. p. 111767. ISSN 0924-4247 https://doi.org/10.1016/j.sna.2019.111767 doi:10.1016/j.sna.2019.111767
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QC Physics
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle QC Physics
TK Electrical engineering. Electronics Nuclear engineering
Patel, Shobhit K.
Parmar, Juveriya
Kosta, Yogeshwar P.
Ladumor, Mayurkumar
Zakaria, Rozalina
Nguyen, Truong Khang
Dhasarathan, Vigneswaran
Design of graphene metasurface based sensitive infrared biosensor
description The article investigates graphene metasurface based infrared biosensor. Graphene metasurface perturbations are added in the Si3N4 waveguide to create leaky wave structure. Biomolecules in blood plasma form are placed over the Si3N4 waveguide to observe the sensing characteristics. Numerical results of absorption, reflectance, electric field and sensitivity are presented in this paper. The sensitivity is calculated from the shift in the absorption peak of biosensor. The sensitivity of the proposed biosensor is also compared with the previously published biosensor designs. In addition, the design results in the form of absorption and reflectance is observed for the different physical parameters like waveguide height (S), biomolecules/air layer height(B), SiO2 layer height(C) and graphene perturbations period(G). The corresponding electric field response is also presented for the proposed design at different frequencies to show the leakage of light in the biomolecules layer. © 2019 Elsevier B.V.
format Article
author Patel, Shobhit K.
Parmar, Juveriya
Kosta, Yogeshwar P.
Ladumor, Mayurkumar
Zakaria, Rozalina
Nguyen, Truong Khang
Dhasarathan, Vigneswaran
author_facet Patel, Shobhit K.
Parmar, Juveriya
Kosta, Yogeshwar P.
Ladumor, Mayurkumar
Zakaria, Rozalina
Nguyen, Truong Khang
Dhasarathan, Vigneswaran
author_sort Patel, Shobhit K.
title Design of graphene metasurface based sensitive infrared biosensor
title_short Design of graphene metasurface based sensitive infrared biosensor
title_full Design of graphene metasurface based sensitive infrared biosensor
title_fullStr Design of graphene metasurface based sensitive infrared biosensor
title_full_unstemmed Design of graphene metasurface based sensitive infrared biosensor
title_sort design of graphene metasurface based sensitive infrared biosensor
publisher Elsevier
publishDate 2020
url http://eprints.um.edu.my/25411/
https://doi.org/10.1016/j.sna.2019.111767
_version_ 1680857029791449088
score 13.211869