Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass

Although brain bypass surgery has often been selected to treat internal carotid arteries (ICA) which are restricted by aneurysm or artery stenosis, its effectiveness has not been quantitatively evaluated. The purpose of this study is to propose an innovative approach for the evaluation of brain extr...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhang, Y., Sia, Sheau Fung, Morgan, M.K., Qian, Y.
Format: Article
Published: Elsevier 2012
Subjects:
Online Access:http://eprints.um.edu.my/23090/
https://doi.org/10.1016/j.jbiomech.2012.02.025
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.23090
record_format eprints
spelling my.um.eprints.230902019-11-22T06:38:02Z http://eprints.um.edu.my/23090/ Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass Zhang, Y. Sia, Sheau Fung Morgan, M.K. Qian, Y. R Medicine Although brain bypass surgery has often been selected to treat internal carotid arteries (ICA) which are restricted by aneurysm or artery stenosis, its effectiveness has not been quantitatively evaluated. The purpose of this study is to propose an innovative approach for the evaluation of brain extracranial-to-intracranial (EC-IC) vein bypass surgery, based on the analysis of flow resistance in vein bypasses and within their contralateral carotid arteries through the use of computational fluid dynamics (CFD). Seven patients who underwent vein bypass surgery were examined with the use of high-resolution; computed tomography angiogram (CTA). The reconstructed three-dimensional (3D) geometries were segmented to create CFD calculation domains. Colour Doppler ultrasound (CDU) was used to measure blood flow velocities at the common carotid arteries (CCA), in order to determine inflow conditions. Based on the pipe flow theory, pressure drop was expressed as Aṁ2+Bṁ where A and B represent flow resistance coefficients and ṁ represents blood mass flow rate. The CFD results revealed that for a healthy ICA, the average values of A and B were 0.013088Pa/(ml/min) 2 and 3.105Pa/(ml/min), respectively. For the vein bypass, an average value of A was 0.0143Pa/(ml/min) 2 and B 3.402Pa/(ml/min), which was approximately that of a healthy ICA. However, in the case of a bypass utilising a venous conduit possessing a large-sized valve or existing size alteration, the flow resistance in that bypass would be higher than those found in the healthy ICA. An imbalance of flow resistances may impose conditions that could predispose hemodynamic failure or distal aneurysm development. © 2012 Elsevier Ltd. Elsevier 2012 Article PeerReviewed Zhang, Y. and Sia, Sheau Fung and Morgan, M.K. and Qian, Y. (2012) Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass. Journal of Biomechanics, 45 (8). pp. 1400-1405. ISSN 0021-9290 https://doi.org/10.1016/j.jbiomech.2012.02.025 doi:10.1016/j.jbiomech.2012.02.025
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine
spellingShingle R Medicine
Zhang, Y.
Sia, Sheau Fung
Morgan, M.K.
Qian, Y.
Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass
description Although brain bypass surgery has often been selected to treat internal carotid arteries (ICA) which are restricted by aneurysm or artery stenosis, its effectiveness has not been quantitatively evaluated. The purpose of this study is to propose an innovative approach for the evaluation of brain extracranial-to-intracranial (EC-IC) vein bypass surgery, based on the analysis of flow resistance in vein bypasses and within their contralateral carotid arteries through the use of computational fluid dynamics (CFD). Seven patients who underwent vein bypass surgery were examined with the use of high-resolution; computed tomography angiogram (CTA). The reconstructed three-dimensional (3D) geometries were segmented to create CFD calculation domains. Colour Doppler ultrasound (CDU) was used to measure blood flow velocities at the common carotid arteries (CCA), in order to determine inflow conditions. Based on the pipe flow theory, pressure drop was expressed as Aṁ2+Bṁ where A and B represent flow resistance coefficients and ṁ represents blood mass flow rate. The CFD results revealed that for a healthy ICA, the average values of A and B were 0.013088Pa/(ml/min) 2 and 3.105Pa/(ml/min), respectively. For the vein bypass, an average value of A was 0.0143Pa/(ml/min) 2 and B 3.402Pa/(ml/min), which was approximately that of a healthy ICA. However, in the case of a bypass utilising a venous conduit possessing a large-sized valve or existing size alteration, the flow resistance in that bypass would be higher than those found in the healthy ICA. An imbalance of flow resistances may impose conditions that could predispose hemodynamic failure or distal aneurysm development. © 2012 Elsevier Ltd.
format Article
author Zhang, Y.
Sia, Sheau Fung
Morgan, M.K.
Qian, Y.
author_facet Zhang, Y.
Sia, Sheau Fung
Morgan, M.K.
Qian, Y.
author_sort Zhang, Y.
title Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass
title_short Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass
title_full Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass
title_fullStr Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass
title_full_unstemmed Flow resistance analysis of extracranial-to-intracranial (EC–IC) vein bypass
title_sort flow resistance analysis of extracranial-to-intracranial (ec–ic) vein bypass
publisher Elsevier
publishDate 2012
url http://eprints.um.edu.my/23090/
https://doi.org/10.1016/j.jbiomech.2012.02.025
_version_ 1651867398240731136
score 13.211869