Strain measurement at temperatures up to 800°C using regenerated gratings produced in the highGe-doped and B/Ge co-doped fibers

In this work, we have proposed a sensor for strain measurement in high-temperature environments up to 800°C by employing two regenerated fiber Bragg gratings. Two seed gratings (SGs) are inscribed in high Ge-doped and B/Ge-codoped fibers, respectively, which possess different temperature sensitiviti...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhang, P., Yang, H.Z., Wang, Y., Liu, H., Lim, Kok Sing, Gunawardena, D.S., Ahmad, Harith
Format: Article
Published: Optical Society of America 2017
Subjects:
Online Access:http://eprints.um.edu.my/18816/
http://dx.doi.org/10.1364/AO.56.006073