DC-link capacitor voltage control for single-phase shunt active power filter with step size error cancellation in self-charging algorithm

This study presents an improved self-charging algorithm by introducing a new feature known as step size error cancellation for better performance of DC-link capacitor voltage control in single-phase shunt active power filter (SAPF). Previous works of self-charging algorithms were focused only for st...

Full description

Saved in:
Bibliographic Details
Main Authors: Zainuri, M.A.A.M., Radzi, M.A.M., Soh, A.C., Mariun, N., Rahim, N.A.
Format: Article
Published: Institution of Engineering and Technology 2016
Subjects:
Online Access:http://eprints.um.edu.my/18699/
http://dx.doi.org/10.1049/iet-pel.2015.0188
Tags: Add Tag
No Tags, Be the first to tag this record!