Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda

Abstract—Nondestructive, noncontact and real time evaluation of dielectric properties of low-loss liquids is important for applications such as service-aged transformer oil, biomedical, remote sensing and design of radar absorbing material. In this paper, present a method for measurement of dielectr...

Full description

Saved in:
Bibliographic Details
Main Author: Che Muda, Nurul Elieya
Format: Article
Language:English
Online Access:https://ir.uitm.edu.my/id/eprint/97536/1/97536.pdf
https://ir.uitm.edu.my/id/eprint/97536/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.97536
record_format eprints
spelling my.uitm.ir.975362024-06-26T15:58:50Z https://ir.uitm.edu.my/id/eprint/97536/ Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda Che Muda, Nurul Elieya Abstract—Nondestructive, noncontact and real time evaluation of dielectric properties of low-loss liquids is important for applications such as service-aged transformer oil, biomedical, remote sensing and design of radar absorbing material. In this paper, present a method for measurement of dielectric properties of transformer oil using metal-backed method. Complex reflection coefficient (Su) is measured for Plexiglas container backed by metal plate. Dielectric constants and loss factor were measured for new and used transformer oil in the frequency range 18 to 26GHz (K-Band).The thru,reflect and line (TRL) calibration technique were used to eliminate the effect of undesirable multiple reflection. The dielectric constant foe new and used transformer oil sample is 2.1+ O.l.The loss tangent (tan 8) foe new transformer oilis 0.02 to 0.06 and for used transformer oil is 0.03 to 0.07.Loss tangent for new transformer oil is lower than used transformer oil Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/97536/1/97536.pdf Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda. pp. 1-5.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description Abstract—Nondestructive, noncontact and real time evaluation of dielectric properties of low-loss liquids is important for applications such as service-aged transformer oil, biomedical, remote sensing and design of radar absorbing material. In this paper, present a method for measurement of dielectric properties of transformer oil using metal-backed method. Complex reflection coefficient (Su) is measured for Plexiglas container backed by metal plate. Dielectric constants and loss factor were measured for new and used transformer oil in the frequency range 18 to 26GHz (K-Band).The thru,reflect and line (TRL) calibration technique were used to eliminate the effect of undesirable multiple reflection. The dielectric constant foe new and used transformer oil sample is 2.1+ O.l.The loss tangent (tan 8) foe new transformer oilis 0.02 to 0.06 and for used transformer oil is 0.03 to 0.07.Loss tangent for new transformer oil is lower than used transformer oil
format Article
author Che Muda, Nurul Elieya
spellingShingle Che Muda, Nurul Elieya
Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda
author_facet Che Muda, Nurul Elieya
author_sort Che Muda, Nurul Elieya
title Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda
title_short Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda
title_full Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda
title_fullStr Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda
title_full_unstemmed Measurement dielectric constant of new transformer oil at frequency 18 to 26 GHz (K Band): article / Nurul Elieya Che Muda
title_sort measurement dielectric constant of new transformer oil at frequency 18 to 26 ghz (k band): article / nurul elieya che muda
url https://ir.uitm.edu.my/id/eprint/97536/1/97536.pdf
https://ir.uitm.edu.my/id/eprint/97536/
_version_ 1802981136237854720
score 13.211869