Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim

Electrochemical analysis on screen printed carbon electrode (SPCE) is relatively simple, rapid and reliable tool inorganic compound identification such as copper in gunshot residue (GSR). SPCE is specially designed to cope with microvolumes of sample such as GSR sample due to its potential for minia...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Hashim, Nurul 'Afiqah Hashimah
Format: Thesis
Language:English
Published: 2019
Online Access:https://ir.uitm.edu.my/id/eprint/95908/1/95908.pdf
https://ir.uitm.edu.my/id/eprint/95908/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.95908
record_format eprints
spelling my.uitm.ir.959082024-09-11T03:34:14Z https://ir.uitm.edu.my/id/eprint/95908/ Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim Mohd Hashim, Nurul 'Afiqah Hashimah Electrochemical analysis on screen printed carbon electrode (SPCE) is relatively simple, rapid and reliable tool inorganic compound identification such as copper in gunshot residue (GSR). SPCE is specially designed to cope with microvolumes of sample such as GSR sample due to its potential for miniaturization and facility of automation. It would be beneficial for the quantification of copper in GSR for a forensic analyst in the fastest way at the discharging area. The coating of gold on SPCE enhances the voltammetric performances towards detection of copper, lead and diphenylamine. The coupling of voltammetry with gold coated SPCEs allows the onsite preliminary test and improves the conventional method which capable to analyze GSR in the laboratory in the long period and have a risk of sample loss. The gold coated SPCE was swabbed directly on the shooter's arm immediately after discharging a firearm and the sample SPCE was analyzed using cyclic voltammetric method. The electrochemical performances of copper, lead and diphenylamine on bare SPCE and gold coated SPCE using voltammetric method were studied. Gold coated SPCE was characterized and optimized before field work. The voltammetric sensor responded to a series of 1 ppm to 100 ppm of copper solution shows gold coated SPCE increased the percentage of reproducibility about 5 % to 17 % in aspect of current density compared to bare SPCE due to their large effective surface area, effective catalysis and fast mass transport. GSR analysis was performed on Glock, Rifle Stryer AUG-Al and Rifle Colt M16-A1 using cyclic voltammetry and Inductive Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) methods. The results obtained from cyclic voltammetric analysis show sopper concentrations detected in Glock, Rifle Stryer AUG-Al and Rifle Colt M16-A1 were 0.680 ppm, 1.349 ppm and 0.707 ppm respectively while the amounts of copper detected by ICP-OES analysis were 0.724 ppm (Glock), 1.432 ppm (Rifle Stryer AUG-Al) and 0.748 ppm (Rifle Colt M16-A1). The paired Student's t-test indicated that there was no significant difference between the results obtained from both methods at the 94 % confidence level. A p-va\ue of less than 0.05 was considered significant. Therefore, it can be concluded that the proposed method is reliable and can be successfully applied to the copper determination in GSR analysis. 2019 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/95908/1/95908.pdf Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim. (2019) Masters thesis, thesis, Universiti Teknologi MARA (UiTM). <http://terminalib.uitm.edu.my/95908.pdf>
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description Electrochemical analysis on screen printed carbon electrode (SPCE) is relatively simple, rapid and reliable tool inorganic compound identification such as copper in gunshot residue (GSR). SPCE is specially designed to cope with microvolumes of sample such as GSR sample due to its potential for miniaturization and facility of automation. It would be beneficial for the quantification of copper in GSR for a forensic analyst in the fastest way at the discharging area. The coating of gold on SPCE enhances the voltammetric performances towards detection of copper, lead and diphenylamine. The coupling of voltammetry with gold coated SPCEs allows the onsite preliminary test and improves the conventional method which capable to analyze GSR in the laboratory in the long period and have a risk of sample loss. The gold coated SPCE was swabbed directly on the shooter's arm immediately after discharging a firearm and the sample SPCE was analyzed using cyclic voltammetric method. The electrochemical performances of copper, lead and diphenylamine on bare SPCE and gold coated SPCE using voltammetric method were studied. Gold coated SPCE was characterized and optimized before field work. The voltammetric sensor responded to a series of 1 ppm to 100 ppm of copper solution shows gold coated SPCE increased the percentage of reproducibility about 5 % to 17 % in aspect of current density compared to bare SPCE due to their large effective surface area, effective catalysis and fast mass transport. GSR analysis was performed on Glock, Rifle Stryer AUG-Al and Rifle Colt M16-A1 using cyclic voltammetry and Inductive Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) methods. The results obtained from cyclic voltammetric analysis show sopper concentrations detected in Glock, Rifle Stryer AUG-Al and Rifle Colt M16-A1 were 0.680 ppm, 1.349 ppm and 0.707 ppm respectively while the amounts of copper detected by ICP-OES analysis were 0.724 ppm (Glock), 1.432 ppm (Rifle Stryer AUG-Al) and 0.748 ppm (Rifle Colt M16-A1). The paired Student's t-test indicated that there was no significant difference between the results obtained from both methods at the 94 % confidence level. A p-va\ue of less than 0.05 was considered significant. Therefore, it can be concluded that the proposed method is reliable and can be successfully applied to the copper determination in GSR analysis.
format Thesis
author Mohd Hashim, Nurul 'Afiqah Hashimah
spellingShingle Mohd Hashim, Nurul 'Afiqah Hashimah
Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim
author_facet Mohd Hashim, Nurul 'Afiqah Hashimah
author_sort Mohd Hashim, Nurul 'Afiqah Hashimah
title Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim
title_short Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim
title_full Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim
title_fullStr Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim
title_full_unstemmed Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim
title_sort copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / nurul 'afiqah hashimah mohd hashim
publishDate 2019
url https://ir.uitm.edu.my/id/eprint/95908/1/95908.pdf
https://ir.uitm.edu.my/id/eprint/95908/
_version_ 1811596721179852800
score 13.211869