Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak
One of the biggest challenges in an islanding operation is to reduce the power imbalance between dispatched power of Distributed Generation (DG) and load demand. A large power imbalance following islanding would cause under-frequency. Hence, an appropriate control is required to shed certain amount...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2013
|
Online Access: | https://ir.uitm.edu.my/id/eprint/87099/1/87099.PDF https://ir.uitm.edu.my/id/eprint/87099/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.87099 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.870992024-04-03T08:57:37Z https://ir.uitm.edu.my/id/eprint/87099/ Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak Abdul Razak, Erma Noraini One of the biggest challenges in an islanding operation is to reduce the power imbalance between dispatched power of Distributed Generation (DG) and load demand. A large power imbalance following islanding would cause under-frequency. Hence, an appropriate control is required to shed certain amount of load. The main objective of this research is to develop an adaptive under-frequency load shedding (UFLS) technique for an islanding system. The technique is designed considering an event-based which includes the moment system is islanded and a tripping of any DG unit during islanding operation. A disturbance magnitude is calculated to determine the amount of load to be shed. The technique is modeled by using PSCAD simulation tool. A simulation studies on a distribution network with mini hydro generation is carried out to evaluate the UFLS model. It is performed under different load condition: peak and base load. The results have shown that the load shedding technique have successfully shed certain amount of load and stabilized the system frequency. 2013 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/87099/1/87099.PDF Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak. (2013) Degree thesis, thesis, Universiti Teknologi MARA (UiTM). |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
description |
One of the biggest challenges in an islanding operation is to reduce the power imbalance between dispatched power of Distributed Generation (DG) and load demand. A large power imbalance following islanding would cause under-frequency. Hence, an appropriate control is required to shed certain amount of load. The main objective of this research is to develop an adaptive under-frequency load shedding (UFLS) technique for an islanding system. The technique is designed considering an event-based which includes the moment system is islanded and a tripping of any DG unit during islanding operation. A disturbance magnitude is calculated to determine the amount of load to be shed. The technique is modeled by using PSCAD simulation tool. A simulation studies on a distribution network with mini hydro generation is carried out to evaluate the UFLS model. It is performed under different load condition: peak and base load. The results have shown that the load shedding technique have successfully shed certain amount of load and stabilized the system frequency. |
format |
Thesis |
author |
Abdul Razak, Erma Noraini |
spellingShingle |
Abdul Razak, Erma Noraini Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak |
author_facet |
Abdul Razak, Erma Noraini |
author_sort |
Abdul Razak, Erma Noraini |
title |
Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak |
title_short |
Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak |
title_full |
Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak |
title_fullStr |
Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak |
title_full_unstemmed |
Under frequency load shedding technique considering event-based for an islanded distribution network / Erma Noraini Abdul Razak |
title_sort |
under frequency load shedding technique considering event-based for an islanded distribution network / erma noraini abdul razak |
publishDate |
2013 |
url |
https://ir.uitm.edu.my/id/eprint/87099/1/87099.PDF https://ir.uitm.edu.my/id/eprint/87099/ |
_version_ |
1797924768716947456 |
score |
13.211869 |