Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris

This paper studies about the symmetrical fault current analysis (3-Phase Faults) in a distribution system with distributed generation and also describes the consequences and operating limitations of installing distribution generator (DG) to electric power systems (distribution system). Transmission...

Full description

Saved in:
Bibliographic Details
Main Author: Md Aris, Mohd Azri
Format: Thesis
Language:English
Published: 2009
Online Access:https://ir.uitm.edu.my/id/eprint/85301/1/85301.pdf
https://ir.uitm.edu.my/id/eprint/85301/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.85301
record_format eprints
spelling my.uitm.ir.853012024-02-14T02:28:34Z https://ir.uitm.edu.my/id/eprint/85301/ Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris Md Aris, Mohd Azri This paper studies about the symmetrical fault current analysis (3-Phase Faults) in a distribution system with distributed generation and also describes the consequences and operating limitations of installing distribution generator (DG) to electric power systems (distribution system). Transmission line faults can be classified using the bus voltage and line fault current. Monitoring the performance of these two factors are very useful for very useful for power system protection devices. This paper will discuss the changes in fault current by comparing the changes during the fault current occur without distribution generator (DG) and with the distribution generator (DG). So this paper will evaluate fault current due to effect in electric power system with the adding of the distribution generator (DG) in distribution system. The simulation will be implemented on an IEEE 69-bus distribution system by using power system simulation programme for planning, design and analysis of distribution system which is Power System Simulator/Advanced Distribution Engineering Productivity Tool (PSS/ADEPT) software. The results of maximum fault current in a distribution system with the presence of DG might be useful for power system engineer to consider protection devices before installing DG in the system. 2009 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/85301/1/85301.pdf Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris. (2009) Degree thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description This paper studies about the symmetrical fault current analysis (3-Phase Faults) in a distribution system with distributed generation and also describes the consequences and operating limitations of installing distribution generator (DG) to electric power systems (distribution system). Transmission line faults can be classified using the bus voltage and line fault current. Monitoring the performance of these two factors are very useful for very useful for power system protection devices. This paper will discuss the changes in fault current by comparing the changes during the fault current occur without distribution generator (DG) and with the distribution generator (DG). So this paper will evaluate fault current due to effect in electric power system with the adding of the distribution generator (DG) in distribution system. The simulation will be implemented on an IEEE 69-bus distribution system by using power system simulation programme for planning, design and analysis of distribution system which is Power System Simulator/Advanced Distribution Engineering Productivity Tool (PSS/ADEPT) software. The results of maximum fault current in a distribution system with the presence of DG might be useful for power system engineer to consider protection devices before installing DG in the system.
format Thesis
author Md Aris, Mohd Azri
spellingShingle Md Aris, Mohd Azri
Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris
author_facet Md Aris, Mohd Azri
author_sort Md Aris, Mohd Azri
title Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris
title_short Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris
title_full Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris
title_fullStr Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris
title_full_unstemmed Fault current analysis in a distribution system with distributed generation / Mohd Azri Md Aris
title_sort fault current analysis in a distribution system with distributed generation / mohd azri md aris
publishDate 2009
url https://ir.uitm.edu.my/id/eprint/85301/1/85301.pdf
https://ir.uitm.edu.my/id/eprint/85301/
_version_ 1792159406370062336
score 13.211869