Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai

The project of fault studies in power system network solar system incorporated is conducted at llkV bus bar to determine the effect of fault by finding out the characteristic of voltage versus time waveform of the grid-connected PV system, 11 kV bus bar and three phase load during fault condition by...

Full description

Saved in:
Bibliographic Details
Main Author: Meringai, Loreta Lily
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/79871/1/79871.pdf
https://ir.uitm.edu.my/id/eprint/79871/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.79871
record_format eprints
spelling my.uitm.ir.798712024-07-28T15:39:08Z https://ir.uitm.edu.my/id/eprint/79871/ Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai Meringai, Loreta Lily TK Electrical engineering. Electronics. Nuclear engineering The project of fault studies in power system network solar system incorporated is conducted at llkV bus bar to determine the effect of fault by finding out the characteristic of voltage versus time waveform of the grid-connected PV system, 11 kV bus bar and three phase load during fault condition by using Matlab/Simulink. Furthermore, to determine which type of fault that cause most severe damage to this system. Other than that, since the main supply of this system is from PV, one of the objectives is to obtain the behavior of PV module by generating the I-V and P-V characteristics curve based on BPSX510 parameter. Besides that, the grid-connected PV system model with 415Vrms output voltage was model. PV system is interfaced to the distribution network through boost converter, two level three phase inverter and the output voltage is step-up using 0.415/11 kV Dllyn transformer. Then, this distribution network is used to supply 415Vrms load through llk/0.415 kV YNdl step-down transformer. The type of fault that is being conducted to the 1 lkV bus bar such as singleline to ground fault, double line to ground fault and line-line fault. The output voltage at grid-connected, llkV distribution network and load was measured and analyzed. The fault that cause severe damage to system is the double line to ground fault. 2014 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/79871/1/79871.pdf Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai. (2014) Degree thesis, thesis, Universiti Teknologi Mara (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic TK Electrical engineering. Electronics. Nuclear engineering
spellingShingle TK Electrical engineering. Electronics. Nuclear engineering
Meringai, Loreta Lily
Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai
description The project of fault studies in power system network solar system incorporated is conducted at llkV bus bar to determine the effect of fault by finding out the characteristic of voltage versus time waveform of the grid-connected PV system, 11 kV bus bar and three phase load during fault condition by using Matlab/Simulink. Furthermore, to determine which type of fault that cause most severe damage to this system. Other than that, since the main supply of this system is from PV, one of the objectives is to obtain the behavior of PV module by generating the I-V and P-V characteristics curve based on BPSX510 parameter. Besides that, the grid-connected PV system model with 415Vrms output voltage was model. PV system is interfaced to the distribution network through boost converter, two level three phase inverter and the output voltage is step-up using 0.415/11 kV Dllyn transformer. Then, this distribution network is used to supply 415Vrms load through llk/0.415 kV YNdl step-down transformer. The type of fault that is being conducted to the 1 lkV bus bar such as singleline to ground fault, double line to ground fault and line-line fault. The output voltage at grid-connected, llkV distribution network and load was measured and analyzed. The fault that cause severe damage to system is the double line to ground fault.
format Thesis
author Meringai, Loreta Lily
author_facet Meringai, Loreta Lily
author_sort Meringai, Loreta Lily
title Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai
title_short Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai
title_full Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai
title_fullStr Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai
title_full_unstemmed Fault studies in a power system network solar system incorporated / Loreta Lily Anak Meringai
title_sort fault studies in a power system network solar system incorporated / loreta lily anak meringai
publishDate 2014
url https://ir.uitm.edu.my/id/eprint/79871/1/79871.pdf
https://ir.uitm.edu.my/id/eprint/79871/
_version_ 1806422060229984256
score 13.211869