Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali

Rebar diameter in structural concrete is an important parameter for a structural engineer to calculate the strength of certain construction. For construction, the critical area for structure is at beam, column and slab. At present only Radiography is the reliable and accurate non-destructive method...

全面介紹

Saved in:
書目詳細資料
主要作者: Md Ali, Mohd Badrul Hisyam
格式: Thesis
語言:English
出版: 2005
主題:
在線閱讀:https://ir.uitm.edu.my/id/eprint/77017/1/77017.pdf
https://ir.uitm.edu.my/id/eprint/77017/
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.uitm.ir.77017
record_format eprints
spelling my.uitm.ir.770172023-08-22T07:58:13Z https://ir.uitm.edu.my/id/eprint/77017/ Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali Md Ali, Mohd Badrul Hisyam Building fittings and their installation Rebar diameter in structural concrete is an important parameter for a structural engineer to calculate the strength of certain construction. For construction, the critical area for structure is at beam, column and slab. At present only Radiography is the reliable and accurate non-destructive method for rebars diameter determination. However, radiography requires accessibility for placement of radiation source and film from both side of the object to be tested and this is not applicable for certain concrete member such as floor slab. In this ultrasonic method, a water column was designed to allow propagation of longitudinal wave into the rebar. A hole of about 15mm diameter was drilled into concrete until it reaches the bar to allow water column to be inserted. Experiment on the laboratory test sample was performed on several rebars of different diameters. At the end of the project, it is observed that UT method is able to gives that accurate bar sizing in concrete. The result of the measurement is in range below than ± 5%. However in these rebar measurement; the output was influenced by numbers of parameters such as Size and shape of the specimen, the distance between rebar, the density or the moisture of the concrete and rebar, the depth of the bar from the surface and temperature. All the parameters need to be considered in order to get a better result. The main parameter which influenced the result is the size of the rebar. 2005 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/77017/1/77017.pdf Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali. (2005) Degree thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Building fittings and their installation
spellingShingle Building fittings and their installation
Md Ali, Mohd Badrul Hisyam
Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali
description Rebar diameter in structural concrete is an important parameter for a structural engineer to calculate the strength of certain construction. For construction, the critical area for structure is at beam, column and slab. At present only Radiography is the reliable and accurate non-destructive method for rebars diameter determination. However, radiography requires accessibility for placement of radiation source and film from both side of the object to be tested and this is not applicable for certain concrete member such as floor slab. In this ultrasonic method, a water column was designed to allow propagation of longitudinal wave into the rebar. A hole of about 15mm diameter was drilled into concrete until it reaches the bar to allow water column to be inserted. Experiment on the laboratory test sample was performed on several rebars of different diameters. At the end of the project, it is observed that UT method is able to gives that accurate bar sizing in concrete. The result of the measurement is in range below than ± 5%. However in these rebar measurement; the output was influenced by numbers of parameters such as Size and shape of the specimen, the distance between rebar, the density or the moisture of the concrete and rebar, the depth of the bar from the surface and temperature. All the parameters need to be considered in order to get a better result. The main parameter which influenced the result is the size of the rebar.
format Thesis
author Md Ali, Mohd Badrul Hisyam
author_facet Md Ali, Mohd Badrul Hisyam
author_sort Md Ali, Mohd Badrul Hisyam
title Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali
title_short Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali
title_full Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali
title_fullStr Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali
title_full_unstemmed Reinforcement bar measurement in structural concrete using ultrasonic method / Mohd Badrul Hisyam Md Ali
title_sort reinforcement bar measurement in structural concrete using ultrasonic method / mohd badrul hisyam md ali
publishDate 2005
url https://ir.uitm.edu.my/id/eprint/77017/1/77017.pdf
https://ir.uitm.edu.my/id/eprint/77017/
_version_ 1775626363805368320
score 13.251813