Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali
The correct eye drop instillation technique plays a major role to ensure the success of the treatment. This study aims to evaluate the eye drop instillation technique in a sample of casual eye drop users and its associated factors. A cross-sectional study was done among self-administered casual eye...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Health Sciences, Universiti Teknologi MARA
2022
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/69741/1/69741.pdf https://ir.uitm.edu.my/id/eprint/69741/ http://healthscopefsk.com/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.69741 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.697412022-11-10T07:48:24Z https://ir.uitm.edu.my/id/eprint/69741/ Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali Alhamzah, Nurazreen Farahin Razak, Shaz’ Ain Mohd Ali, Nor Azeera Sense Organs RE Ophthalmology The correct eye drop instillation technique plays a major role to ensure the success of the treatment. This study aims to evaluate the eye drop instillation technique in a sample of casual eye drop users and its associated factors. A cross-sectional study was done among self-administered casual eye drop users and their details had been profiled. All subjects were asked to demonstrate their instillation technique while a video recorder was used for recording and a grading chart was referred to score the technique from -1 to +4. A total of 50 subjects with 11 (22.0%) male and 39 (78.0%) female with a mean age of 22.14 (±2.70) years were involved. The major reason for eye drop usage is dryness (58.0%) followed by itchiness (14.0%), redness (12.0%), combination (12.0%), and others (4.0%). 28 (56.0%) of subjects had non-prescribed eye drop while 30 (60.0%) had no previous education regarding proper instillation techniques. Mean instillation technique score is 2.26 (±1.43) with 26 (52.0%) subjects having poor instillation techniques. In conclusion, majority of subjects had a poor technique in instilling eye drops. Thus, future research should emphasize on best methods of eye drops prescription to ensure the effectiveness of medication through self-instillation eye drops. Faculty of Health Sciences, Universiti Teknologi MARA 2022-10 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/69741/1/69741.pdf Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali. (2022) Healthscope, 5 (1). pp. 37-41. ISSN 2735-0649 http://healthscopefsk.com/ |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Sense Organs RE Ophthalmology |
spellingShingle |
Sense Organs RE Ophthalmology Alhamzah, Nurazreen Farahin Razak, Shaz’ Ain Mohd Ali, Nor Azeera Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali |
description |
The correct eye drop instillation technique plays a major role to ensure the success of the treatment. This study aims to evaluate the eye drop instillation technique in a sample of casual eye drop users and its associated factors. A cross-sectional study was done among self-administered casual eye drop users and their details had been profiled. All subjects were asked to demonstrate their instillation technique while a video recorder was used for recording and a grading chart was referred to score the technique from -1 to +4. A total of 50 subjects with 11 (22.0%) male and 39 (78.0%) female with a mean age of 22.14 (±2.70) years were involved. The major reason for eye drop usage is dryness (58.0%) followed by itchiness (14.0%), redness (12.0%), combination (12.0%), and others (4.0%). 28 (56.0%) of subjects had non-prescribed eye drop while 30 (60.0%) had no previous education regarding proper instillation techniques. Mean instillation technique score is 2.26 (±1.43) with 26 (52.0%) subjects having poor instillation techniques. In conclusion, majority of subjects had a poor technique in instilling eye drops. Thus, future research should emphasize on best methods of eye drops prescription to ensure the effectiveness of medication through self-instillation eye drops. |
format |
Article |
author |
Alhamzah, Nurazreen Farahin Razak, Shaz’ Ain Mohd Ali, Nor Azeera |
author_facet |
Alhamzah, Nurazreen Farahin Razak, Shaz’ Ain Mohd Ali, Nor Azeera |
author_sort |
Alhamzah, Nurazreen Farahin |
title |
Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali |
title_short |
Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali |
title_full |
Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali |
title_fullStr |
Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali |
title_full_unstemmed |
Evaluation of eye drop self-administration technique in a sample of casual eye drop users / Nurazreen Farahin Alhamzah, Shaz’ Ain Razak and Nor Azeera Mohd Ali |
title_sort |
evaluation of eye drop self-administration technique in a sample of casual eye drop users / nurazreen farahin alhamzah, shaz’ ain razak and nor azeera mohd ali |
publisher |
Faculty of Health Sciences, Universiti Teknologi MARA |
publishDate |
2022 |
url |
https://ir.uitm.edu.my/id/eprint/69741/1/69741.pdf https://ir.uitm.edu.my/id/eprint/69741/ http://healthscopefsk.com/ |
_version_ |
1751539963467399168 |
score |
13.211869 |