Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar

The main indication for a shoulder replacement is pain relief. Occasionally, shoulder replacement surgery is needed for certain fractures around the shoulder, but most shoulder replacements occur after years of wear, tear and dislocation of the glenoid joint on the shoulder. The humeral head rarely...

詳細記述

保存先:
書誌詳細
第一著者: Abu Bakar, Rushafinas
フォーマット: 学位論文
言語:English
出版事項: 2010
主題:
オンライン・アクセス:https://ir.uitm.edu.my/id/eprint/68437/1/68437.pdf
https://ir.uitm.edu.my/id/eprint/68437/
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
id my.uitm.ir.68437
record_format eprints
spelling my.uitm.ir.684372022-10-13T06:42:45Z https://ir.uitm.edu.my/id/eprint/68437/ Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar Abu Bakar, Rushafinas The Articulations, Joints Surgery by region, system, or organ The main indication for a shoulder replacement is pain relief. Occasionally, shoulder replacement surgery is needed for certain fractures around the shoulder, but most shoulder replacements occur after years of wear, tear and dislocation of the glenoid joint on the shoulder. The humeral head rarely can dislocate from the glenoid component because of the different mismatch sizes of prosthesis stem with the patient. The aim of this study is to see the implication of the Asian proximal humerus geometric to the previous shoulder prosthesis design and construct a possible size of shoulder prosthesis stem for Asian. The scope of this study is to perform the Finite Element Analysis on Asian and Caucasian shoulder with the implemented implant. The dimension of shoulder was based on previous Anthropometric measurement data. The shoulder prosthesis used in this study is a Zimmer Anatomical Shoulder Systems. It's the third generation of stem designs. The material was used is Titanium Alloy Ti-6A1-4V. The loading that has to be considered is muscle force at average body weight. The distal end of the humerus is fixed. Results, shows that the stress distribution of shoulder with implemented stem. Analysis of this shoulder is sufficient to study the stress behavior of the TSR on humerus bone. The stresses for the TSR on humerus bone were reduced at modified design size compared to existing design size. 2010 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/68437/1/68437.pdf Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar. (2010) Degree thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic The Articulations, Joints
Surgery by region, system, or organ
spellingShingle The Articulations, Joints
Surgery by region, system, or organ
Abu Bakar, Rushafinas
Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
description The main indication for a shoulder replacement is pain relief. Occasionally, shoulder replacement surgery is needed for certain fractures around the shoulder, but most shoulder replacements occur after years of wear, tear and dislocation of the glenoid joint on the shoulder. The humeral head rarely can dislocate from the glenoid component because of the different mismatch sizes of prosthesis stem with the patient. The aim of this study is to see the implication of the Asian proximal humerus geometric to the previous shoulder prosthesis design and construct a possible size of shoulder prosthesis stem for Asian. The scope of this study is to perform the Finite Element Analysis on Asian and Caucasian shoulder with the implemented implant. The dimension of shoulder was based on previous Anthropometric measurement data. The shoulder prosthesis used in this study is a Zimmer Anatomical Shoulder Systems. It's the third generation of stem designs. The material was used is Titanium Alloy Ti-6A1-4V. The loading that has to be considered is muscle force at average body weight. The distal end of the humerus is fixed. Results, shows that the stress distribution of shoulder with implemented stem. Analysis of this shoulder is sufficient to study the stress behavior of the TSR on humerus bone. The stresses for the TSR on humerus bone were reduced at modified design size compared to existing design size.
format Thesis
author Abu Bakar, Rushafinas
author_facet Abu Bakar, Rushafinas
author_sort Abu Bakar, Rushafinas
title Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_short Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_full Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_fullStr Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_full_unstemmed Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_sort shoulder prosthesis stem design based on anthropometric measurement data for asian population / rushafinas abu bakar
publishDate 2010
url https://ir.uitm.edu.my/id/eprint/68437/1/68437.pdf
https://ir.uitm.edu.my/id/eprint/68437/
_version_ 1748183913101000704
score 13.250246