Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir

One of the main problem of Cascaded-Helical Magnetic Flux Compression Generators (Cascaded-HFCG) is the returned energy from second stage winding to first stage winding after starting of second stage operation. Since there is no electrical connection between first stage winding and the load of...

Full description

Saved in:
Bibliographic Details
Main Authors: Jafarifar, M., Rezaeelam, B., Mir, A.
Format: Article
Language:English
Published: UiTM Press 2018
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/63118/1/63118.pdf
https://ir.uitm.edu.my/id/eprint/63118/
https://jeesr.uitm.edu.my/v1/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.63118
record_format eprints
spelling my.uitm.ir.631182022-06-29T06:27:41Z https://ir.uitm.edu.my/id/eprint/63118/ Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir Jafarifar, M. Rezaeelam, B. Mir, A. Dynamoelectric machinery and auxiliaries.Including generators, motors, transformers One of the main problem of Cascaded-Helical Magnetic Flux Compression Generators (Cascaded-HFCG) is the returned energy from second stage winding to first stage winding after starting of second stage operation. Since there is no electrical connection between first stage winding and the load of the generator, so a great part of energy doesn't reach to the load and losts. This energy loss cause to decrease in generator efficiency and has a great impact on output characteristic of the generator. In this paper, an approach is proposed to minimize returned energy and to improve the output characteristic of a Cascaded-HFCG. The approach is based on time-varying primary winding of dynamic transformer and addition of a gradually incremental resistance in series with the first stage winding. In order to verificate the ability of the proposed approach, a computer code is programed based on a simple model of the generator and a Cascaded-HFCG is simulated for two cases: first case for the conventional generator and the other for the proposed approach. It is demonstrated that for the proposed approach, the output current has a greater value, consequently the current gain of the generator becomes better. The comparison between output currents for two cases shows that the rise-time of output current becomes smaller for the case of proposed approach. UiTM Press 2018-12 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/63118/1/63118.pdf Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir. (2018) Journal of Electrical and Electronic Systems Research (JEESR), 13: 12. pp. 86-90. ISSN 1985-5389 https://jeesr.uitm.edu.my/v1/
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Dynamoelectric machinery and auxiliaries.Including generators, motors, transformers
spellingShingle Dynamoelectric machinery and auxiliaries.Including generators, motors, transformers
Jafarifar, M.
Rezaeelam, B.
Mir, A.
Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir
description One of the main problem of Cascaded-Helical Magnetic Flux Compression Generators (Cascaded-HFCG) is the returned energy from second stage winding to first stage winding after starting of second stage operation. Since there is no electrical connection between first stage winding and the load of the generator, so a great part of energy doesn't reach to the load and losts. This energy loss cause to decrease in generator efficiency and has a great impact on output characteristic of the generator. In this paper, an approach is proposed to minimize returned energy and to improve the output characteristic of a Cascaded-HFCG. The approach is based on time-varying primary winding of dynamic transformer and addition of a gradually incremental resistance in series with the first stage winding. In order to verificate the ability of the proposed approach, a computer code is programed based on a simple model of the generator and a Cascaded-HFCG is simulated for two cases: first case for the conventional generator and the other for the proposed approach. It is demonstrated that for the proposed approach, the output current has a greater value, consequently the current gain of the generator becomes better. The comparison between output currents for two cases shows that the rise-time of output current becomes smaller for the case of proposed approach.
format Article
author Jafarifar, M.
Rezaeelam, B.
Mir, A.
author_facet Jafarifar, M.
Rezaeelam, B.
Mir, A.
author_sort Jafarifar, M.
title Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir
title_short Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir
title_full Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir
title_fullStr Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir
title_full_unstemmed Improved characteristic of load current of cascaded-flux compression generator / M. Jafarifar, B. Rezaeealam and A.Mir
title_sort improved characteristic of load current of cascaded-flux compression generator / m. jafarifar, b. rezaeealam and a.mir
publisher UiTM Press
publishDate 2018
url https://ir.uitm.edu.my/id/eprint/63118/1/63118.pdf
https://ir.uitm.edu.my/id/eprint/63118/
https://jeesr.uitm.edu.my/v1/
_version_ 1738514004852080640
score 13.211869