Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid
Dust explosion possibly occurs in common unit operations such as mills, grinders, dryers, and other modes of transport. The basic element for the setting of hazardous zone types consist of identifies release sources, determination of classification region of hazardous area, overviewing the basic ope...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Teknologi MARA
2021
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/58910/1/58910.pdf https://ir.uitm.edu.my/id/eprint/58910/ https://myjms.mohe.gov.my |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.58910 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.589102022-04-26T15:22:29Z https://ir.uitm.edu.my/id/eprint/58910/ Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid Ahmad, Mohd Aizad Noor Azman, Muhammad Naqib Saifullah Abdul Rashid, Zulkifli Mechanics applied to machinery. Dynamics Machine design and drawing Dust explosion possibly occurs in common unit operations such as mills, grinders, dryers, and other modes of transport. The basic element for the setting of hazardous zone types consist of identifies release sources, determination of classification region of hazardous area, overviewing the basic operation in wheat flour processing plant with their specification requirement and use of a suitable code or calculations to determine area scope. Therefore, this analysis can be more elaborate by classifying the hazardous area into several areas using the International Electro Technical Commission System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres standard. Thus, wheat flour processing plant area classification can be categorized according to three zones based on the quantity of an explosion into atmosphere and its release frequencies which are zones 20, zones 21, and zones 22. From the results, it can be summarized that zone 20 is almost inside or closer one with the main equipment located near the ignition source which could lead to dust explosion, whereas zone 21 and zone 22 comes after zone 20 which is a less hazardous area as compared to zone 20 areas. Universiti Teknologi MARA 2021-10 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/58910/1/58910.pdf (2021) Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid. Malaysian Journal of Chemical Engineering and Technology (MJCET), 4 (2): 12. pp. 172-183. ISSN (e-ISSN): 2682-8588 https://myjms.mohe.gov.my |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Mechanics applied to machinery. Dynamics Machine design and drawing |
spellingShingle |
Mechanics applied to machinery. Dynamics Machine design and drawing Ahmad, Mohd Aizad Noor Azman, Muhammad Naqib Saifullah Abdul Rashid, Zulkifli Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid |
description |
Dust explosion possibly occurs in common unit operations such as mills, grinders, dryers, and other modes of transport. The basic element for the setting of hazardous zone types consist of identifies release sources, determination of classification region of hazardous area, overviewing the basic operation in wheat flour processing plant with their specification requirement and use of a suitable code or calculations to determine area scope. Therefore, this analysis can be more elaborate by classifying the hazardous area into several areas using the International Electro Technical Commission System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres standard. Thus, wheat flour processing plant area classification can be categorized according to three zones based on the quantity of an explosion into atmosphere and its release frequencies which are zones 20, zones 21, and zones 22. From the results, it can be summarized that zone 20 is almost inside or closer one with the main equipment located near the ignition source which could lead to dust explosion, whereas zone 21 and zone 22 comes after zone 20 which is a less hazardous area as compared to zone 20 areas. |
format |
Article |
author |
Ahmad, Mohd Aizad Noor Azman, Muhammad Naqib Saifullah Abdul Rashid, Zulkifli |
author_facet |
Ahmad, Mohd Aizad Noor Azman, Muhammad Naqib Saifullah Abdul Rashid, Zulkifli |
author_sort |
Ahmad, Mohd Aizad |
title |
Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid |
title_short |
Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid |
title_full |
Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid |
title_fullStr |
Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid |
title_full_unstemmed |
Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid |
title_sort |
hazardous area classification for wheat flour processing plant / mohd aizad ahmad, muhammad naqib saifullah noor azman and zulkifli abdul rashid |
publisher |
Universiti Teknologi MARA |
publishDate |
2021 |
url |
https://ir.uitm.edu.my/id/eprint/58910/1/58910.pdf https://ir.uitm.edu.my/id/eprint/58910/ https://myjms.mohe.gov.my |
_version_ |
1731229130152738816 |
score |
13.211869 |