Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani

Reinforced concrete slab is an important structure component in a building. Reinforced concrete that has been used for a long time should be evaluated to determine the current strength and durability. Reinforced concrete of poor quality that has a reduced strength will not only cause discomfort to c...

Full description

Saved in:
Bibliographic Details
Main Authors: Muftah, Fadhluhartini, Ab. Rahman, Marzuki, Mohd Sani, Mohd Syahrul Hisyam
Format: Conference or Workshop Item
Language:English
Published: 2010
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/58172/1/58172.PDF
https://ir.uitm.edu.my/id/eprint/58172/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.58172
record_format eprints
spelling my.uitm.ir.581722022-06-08T10:23:32Z https://ir.uitm.edu.my/id/eprint/58172/ Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani Muftah, Fadhluhartini Ab. Rahman, Marzuki Mohd Sani, Mohd Syahrul Hisyam Malaysia Building inspection Construction equipment in building Reinforced concrete slab is an important structure component in a building. Reinforced concrete that has been used for a long time should be evaluated to determine the current strength and durability. Reinforced concrete of poor quality that has a reduced strength will not only cause discomfort to customers but also affect their safety. If the problem is not monitored and no improvement is made, the reinforced concrete will fail and eventually collapse. The former civil engineering laboratory building that had been used for 10 years from 2000 to 2010 was investigated for its integrity. In this study, the soil mechanics laboratory was prepared and assessed. The testing instruments used in this study were rebound hammer test and pundit test. The rebound hammer test was used to determine the current strength while the pundit test was used to investigate the pulse velocity, presence of crack and also properties of concrete. From the data, it was found that the laboratory's concrete slab achieved a 30-40 MPa for current compressive strength whereas the Pundit Test showed that the quality of concrete in the laboratory still had a good condition but doubtful in concrete quality. The reinforced concrete slab for this laboratory also showed consistent strength and no large or medium cracks were detected. Thus, the reinforced concrete slab at the former civil engineering laboratory was safe and had moderate integrity. 2010 Conference or Workshop Item PeerReviewed text en https://ir.uitm.edu.my/id/eprint/58172/1/58172.PDF Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani. (2010) In: Prosiding KONAKA Konferensi Akademik 2010, 8-9 Disember 2010, UiTM PAHANG.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Malaysia
Building inspection
Construction equipment in building
spellingShingle Malaysia
Building inspection
Construction equipment in building
Muftah, Fadhluhartini
Ab. Rahman, Marzuki
Mohd Sani, Mohd Syahrul Hisyam
Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani
description Reinforced concrete slab is an important structure component in a building. Reinforced concrete that has been used for a long time should be evaluated to determine the current strength and durability. Reinforced concrete of poor quality that has a reduced strength will not only cause discomfort to customers but also affect their safety. If the problem is not monitored and no improvement is made, the reinforced concrete will fail and eventually collapse. The former civil engineering laboratory building that had been used for 10 years from 2000 to 2010 was investigated for its integrity. In this study, the soil mechanics laboratory was prepared and assessed. The testing instruments used in this study were rebound hammer test and pundit test. The rebound hammer test was used to determine the current strength while the pundit test was used to investigate the pulse velocity, presence of crack and also properties of concrete. From the data, it was found that the laboratory's concrete slab achieved a 30-40 MPa for current compressive strength whereas the Pundit Test showed that the quality of concrete in the laboratory still had a good condition but doubtful in concrete quality. The reinforced concrete slab for this laboratory also showed consistent strength and no large or medium cracks were detected. Thus, the reinforced concrete slab at the former civil engineering laboratory was safe and had moderate integrity.
format Conference or Workshop Item
author Muftah, Fadhluhartini
Ab. Rahman, Marzuki
Mohd Sani, Mohd Syahrul Hisyam
author_facet Muftah, Fadhluhartini
Ab. Rahman, Marzuki
Mohd Sani, Mohd Syahrul Hisyam
author_sort Muftah, Fadhluhartini
title Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani
title_short Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani
title_full Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani
title_fullStr Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani
title_full_unstemmed Investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / Fadhluhartini Muftah, Marzuki Ab. Rahman and Mohd Syahrul Hisyam Mohd Sani
title_sort investigation on the integrity of the reinforced concrete slab at the former civil engineering laboratory building / fadhluhartini muftah, marzuki ab. rahman and mohd syahrul hisyam mohd sani
publishDate 2010
url https://ir.uitm.edu.my/id/eprint/58172/1/58172.PDF
https://ir.uitm.edu.my/id/eprint/58172/
_version_ 1735389622393896960
score 13.211869