Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat
Automatic room power control is used to switch ‘ON’ and ‘OFF’ the light automatically. In this circuit we use two LDRs, which are placed one after another. So that they may separately sense the person going into or coming out of the room. The output of two LDR senses are used in conjunction with a...
Saved in:
Main Authors: | , |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2001
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/48381/1/48381.pdf http://ir.uitm.edu.my/id/eprint/48381/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.48381 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.483812021-07-22T08:04:56Z http://ir.uitm.edu.my/id/eprint/48381/ Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat Mohd Busri, Maizatul Sahrina Mahamat, Suhaiza TK Electrical engineering. Electronics. Nuclear engineering Electronics Apparatus and materials Semiconductors Microelectromechanical systems Applications of electronics Automatic room power control is used to switch ‘ON’ and ‘OFF’ the light automatically. In this circuit we use two LDRs, which are placed one after another. So that they may separately sense the person going into or coming out of the room. The output of two LDR senses are used in conjunction with a bicolor LED that when the person get into the room it emit green light and when person goes out of the room it emit red light and vice versa. These outputs are simultaneously applied to two counters. One of the counter will count as +1, +2, +3 etc that when the persons are getting into the room and the other will count as -1, -2, -3 etc when persons are getting out of room. These counter make use of Johnson decade counter CD4017 ICs. The next stage comprise two logic ICs which can combine the output of two counters and determine if there is any person still leave in the room or not. The output of the two counters are ended by AND gates and the wired ORed. 2001-09-20 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/48381/1/48381.pdf ID48381 Mohd Busri, Maizatul Sahrina and Mahamat, Suhaiza (2001) Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat. [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics. Nuclear engineering Electronics Apparatus and materials Semiconductors Microelectromechanical systems Applications of electronics |
spellingShingle |
TK Electrical engineering. Electronics. Nuclear engineering Electronics Apparatus and materials Semiconductors Microelectromechanical systems Applications of electronics Mohd Busri, Maizatul Sahrina Mahamat, Suhaiza Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat |
description |
Automatic room power control is used to switch ‘ON’ and ‘OFF’ the light automatically.
In this circuit we use two LDRs, which are placed one after another. So that they may separately sense the person going into or coming out of the room. The output of two LDR senses are used in conjunction with a bicolor LED that when the person get into the room it emit green light and when person goes out of the room it emit red light and vice
versa.
These outputs are simultaneously applied to two counters. One of the counter will count as +1, +2, +3 etc that when the persons are getting into the room and the other will count as -1, -2, -3 etc when persons are getting out of room. These counter make use of Johnson decade counter CD4017 ICs. The next stage comprise two logic ICs which can combine the output of two counters and determine if there is any person still leave in the room or not. The output of the two counters are ended by AND gates and the wired ORed. |
format |
Student Project |
author |
Mohd Busri, Maizatul Sahrina Mahamat, Suhaiza |
author_facet |
Mohd Busri, Maizatul Sahrina Mahamat, Suhaiza |
author_sort |
Mohd Busri, Maizatul Sahrina |
title |
Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat |
title_short |
Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat |
title_full |
Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat |
title_fullStr |
Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat |
title_full_unstemmed |
Automatic room power control / Maizatul Sahrina Mohd Busri and Suhaiza Mahamat |
title_sort |
automatic room power control / maizatul sahrina mohd busri and suhaiza mahamat |
publishDate |
2001 |
url |
http://ir.uitm.edu.my/id/eprint/48381/1/48381.pdf http://ir.uitm.edu.my/id/eprint/48381/ |
_version_ |
1706960411782283264 |
score |
13.211869 |